Abstract: This paper presents a synthetic jet air blower actuated
by PZT for air blowing for air-breathing micro PEM fuel cell. The
several factors to affect the performance of air-breathing PEM fuel cell
such as air flow rate, opening ratio and cathode open type in the
cathode side were studied. Especially, an air flow rate is critical
condition to improve its performance. In this paper, we developed a
synthetic jet air blower to supply a high stoichiometric air flow. The
synthetic jet mechanism is a zero mass flux device that converts
electrical energy into the momentum. The synthetic jet actuation is
usually generated by a traditional PZT actuator, which consists of a
small cylindrical cavity, in/outlet channel and PZT diaphragms. The
flow rate of the fabricated synthetic jet air blower was 400cc/min at
550Hz and its power consumption was very low under 0.3W. The
proposed air-breathing PEM fuel cell which installed synthetic jet air
blower was higher performance and stability during continuous
operation than the air-breathing fuel cell without auxiliary device to
supply the air. The results showed that the maximum power density
was 188mW/cm2 at 400mA/cm2. This maximum power density and
durability were improved more than 40% and 20%, respectively.
Abstract: Fluid flow in cylinders of elliptic cross-section was investigated. Fluid used is Liquefied petroleum gas (LPG). LPG found in Nigeria contains majorly butane with percentages of propane. Commercial available code FLUENT which uses finite volume method was used to solve fluid flow governing equations. There has been little attention paid to fluid flow in cylindrical elliptic pipes. The present work aims to predict the LPG gas flow in cylindrical pipes of elliptic cross-section. Results of flow parameters of velocity and pressure distributions are presented. Results show that the pressure drop in elliptic pipes is higher than circular pipe of the same cross-sectional area. This is an important result as the pressure drop is related to the pump power needed to drive the flow. Results show that the velocity increases towards centre of the pipe as the flow moves downstream, and also increases towards the outlet of the pipe.
Abstract: This study investigated the presence of polycyclic
aromatic hydrocarbons (PAHs) in the sediments of the Musa Bay
(around the PETZONE coastal area) from Feb 2010 to Jun 2010.
Concentrations of PAHs recorded in the Musa Bay sediments ranged
from 537.89 to 26,659.06 ng/g dry weight with a mean value of
3990.74 ng/g. the highest concentration of PAHs was observed at
station 4, which is located near the aromatic outlet of Imam
Khomeini petrochemical company (station 4: BI-PC Aromatic
effluent outlet) in which its concentration level was more than the
NOAA sediment quality guideline value (ERL= 4022 ng/g dry
weight). Owing to the concentration of PAHs in the study area, its
concentration level was still meet the NOAA sediment quality
guideline value (ERL: 4022 ng/g dry weight); however, according to
the PELq factor, slightly adverse biological effects are associated
with the exposure to PAHs levels in the study area (0.1< PELq= 0.24
> 0.5).
Abstract: Aircraft propulsion systems often use Y-shaped
subsonic diffusing ducts as twin air-intakes to supply the ambient air
into the engine compressor for thrust generation. Due to space
constraint, the diffusers need to be curved, which causes severe flow
non-uniformity at the engine face. The present study attempt to
control flow in a mild-curved Y-duct diffuser using trapezoidalshaped
vortex generators (VG) attached on either both the sidewalls
or top and bottom walls of the diffuser at the inflexion plane. A
commercial computational fluid dynamics (CFD) code is modified
and is used to simulate the effects of SVG in flow of a Y-duct
diffuser. A few experiments are conducted for CFD code validation,
while the rest are done computationally. The best combination of Yduct
diffuser is found with VG-2 arranged in co-rotating sequence
and attached to both the sidewalls, which ensures highest static
pressure recovery, lowest total pressure loss, minimum flow
distortion and less flow separation in Y-duct diffuser. The decrease in
VG height while attached to top and bottom walls further improves
axial flow uniformity at the diffuser outlet by a great margin as
compared to the bare duct.
Abstract: This paper presents the experimental as well as the
simulated performance studies on the transcritical CO2 heat pumps
for simultaneous water cooling and heating; effects of water mass
flow rates and water inlet temperatures of both evaporator and gas
cooler on the cooling and heating capacities, system COP and water
outlets temperatures are investigated. Study shows that both the
water mass flow rate and inlet temperature have significant effect on
system performances. Test results show that the effect of evaporator
water mass flow rate on the system performances and water outlet
temperatures is more pronounced (COP increases 0.6 for 1 kg/min)
compared to the gas cooler water mass flow rate (COP increases 0.4
for 1 kg/min) and the effect of gas cooler water inlet temperature is
more significant (COP decreases 0.48 for given ranges) compared to
the evaporator water inlet temperature (COP increases 0.43 for given
ranges). Comparisons of experimental values with simulated results
show the maximum deviation of 5% for cooling capacity, 10% for
heating capacity, 16% for system COP. This study offers useful
guidelines for selecting appropriate water mass flow rate to obtain
required system performance.
Abstract: In a pilot plant scale of a fluidized bed reactor, a
reduction reaction of sodium sulfate by natural gas has been
investigated. Natural gas is applied in this study as a reductant. Feed
density, feed mass flow rate, natural gas and air flow rate
(independent parameters)and temperature of bed and CO
concentration in inlet and outlet of reactor (dependent parameters)
were monitored and recorded at steady state. The residence time was
adjusted close to value of traditional reaction [1]. An artificial neural
network (ANN) was established to study dependency of yield and
carbon gradient on operating parameters. Resultant 97% accuracy of
applied ANN is a good prove that natural gas can be used as a
reducing agent. Predicted ANN model for relation between other
sources carbon gradient (accuracy 74%) indicates there is not a
meaningful relation between other sources carbon variation and
reduction process which means carbon in granule does not have
significant effect on the reaction yield.
Abstract: Gas turbine systems with wet compression have a
potential for future power generation, since they can offer a high
efficiency and a high specific power with a relatively low cost. In this
study influence of ambient condition on the performance of the wet
compression process is investigated with a non-equilibrium analytical
modeling based on droplet evaporation. Transient behaviors of droplet
diameter and temperature of mixed air are investigated for various
ambient temperatures. Special attention is paid for the effects of
ambient temperature, pressure ratio, and water injection ratios on the
important wet compression variables including compressor outlet
temperature and compression work. Parametric studies show that
downing of the ambient temperature leads to lower compressor outlet
temperature and consequently lower consumption of compression
work even in wet compression processes.
Abstract: Today, incorrect use of lands and land use changes,
excessive grazing, no suitable using of agricultural farms, plowing on
steep slopes, road construct, building construct, mine excavation etc
have been caused increasing of soil erosion and sediment yield. For
erosion and sediment estimation one can use statistical and empirical
methods. This needs to identify land unit map and the map of
effective factors. However, these empirical methods are usually time
consuming and do not give accurate estimation of erosion. In this
study, we applied GIS techniques to estimate erosion and sediment of
Menderjan watershed at upstream Zayandehrud river in center of
Iran. Erosion faces at each land unit were defined on the basis of land
use, geology and land unit map using GIS. The UTM coordinates of
each erosion type that showed more erosion amounts such as rills and
gullies were inserted in GIS using GPS data. The frequency of
erosion indicators at each land unit, land use and their sediment yield
of these indices were calculated. Also using tendency analysis of
sediment yield changes in watershed outlet (Menderjan hydrometric
gauge station), was calculated related parameters and estimation
errors. The results of this study according to implemented watershed
management projects can be used for more rapid and more accurate
estimation of erosion than traditional methods. These results can also
be used for regional erosion assessment and can be used for remote
sensing image processing.
Abstract: Nowadays, new home appliances and office appliances
have been developed that communicate with users through the
Internet, for remote monitor and remote control. However, developments
and sales of these new appliances are just started, then,
many products in our houses and offices do not have these useful
functions. In few years, we add these new functions to the outlet,
it means multifunctional electrical power socket plug adapter. The
outlet measure power consumption of connecting appliances, and it
can switch power supply to connecting appliances, too. Using this
outlet, power supply of old appliances can be control and monitor.
And we developed the interface system using web browser to operate
it from users[1]. But, this system need to set up LAN cables between
outlets and so on. It is not convenience that cables around rooms. In
this paper, we develop the system that use wireless mobile ad hoc
network instead of wired LAN to communicate with the outlets.
Abstract: A techno-economic evaluation for efficient use of
energy in a large scale industrial plant of methanol is carried out.
This assessment is based on integration of a gas turbine with an
existing plant of methanol in which the outlet gas products of
exothermic reactor is expanded to power generation. Also, it is
decided that methanol production rate is constant through addition of
power generation system to the existing methanol plant. Having
incorporated a gas turbine with the existing plant, the economic
results showed total investment of MUSD 16.9, energy saving of 3.6
MUSD/yr with payback period of approximately 4.7 years.
Abstract: In this paper, three dimensional flow characteristic was
presented by a revision of an impeller of an axial turbo fan for
improving the airflow rate and the static pressure. TO consider an
incompressible steady three-dimensional flow, the RANS equations
are used as the governing equations, and the standard k-ε turbulence
model is chosen. The pitch angles of 44°, 54°, 59°, and 64° are
implemented for the numerical model. The numerical results show that
airflow rates of each pitch angle are 1,175 CMH, 1,270 CMH, 1,340
CMH, and 800 CMH, respectively. The difference of the static
pressure at impeller inlet and outlet are 120 Pa, 214 Pa, 242 Pa, and 60
Pa according to respective pitch angles. It means that the 59° of the
impeller pitch angle is optimal to improve the airflow rate and the
static pressure.
Abstract: In order to compare the performance of the carbon dioxide and HFC-125 heat pumps for medium-and high-temperature heating, both heat pump cycles were optimized using a simulation method. To fairly compare the performance of the cycles by using different working fluids, each cycle was optimized from the viewpoint of heating COP by two design parameters. The first is the gas cooler exit temperature and the other is the ratio of the overall heat conductance of the gas cooler to the combined overall heat conductance of the gas cooler and the evaporator. The inlet and outlet temperatures of secondary fluid of the gas cooler were fixed at 40/90°C and 40/150°C.The results shows that the HFC-125 heat pump has 6% higher heating COP than carbon dioxide heat pump when the heat sink exit temperature is fixed at 90ºC, while the latter outperforms the former when the heat sink exit temperature is fixed at 150ºC under the simulation conditions considered in the present study.
Abstract: Future space vehicles will require the use of non-toxic, cryogenic propellants, because of the performance advantages over the toxic hypergolic propellants and also because of the environmental and handling concerns. A prototypical capillary flow liquid acquisition device (LAD) for cryogenic propellants was fabricated with a mesh screen, covering a rectangular flow channel with a cylindrical outlet tube, and was tested with liquid oxygen (LOX). In order to better understand the performance in various gravity environments and orientations with different submersion depths of the LAD, a series of computational fluid dynamics (CFD) simulations of LOX flow through the LAD screen channel, including horizontally and vertically submersions of the LAD channel assembly at normal gravity environment was conducted. Gravity effects on the flow field in LAD channel are inspected and analyzed through comparing the simulations.
Abstract: The counter flow solar air heaters, with four
transverse fins and wire mesh layers are constructed and investigated
experimentally for thermal efficiency at a geographic location of
Cyprus in the city of Famagusta. The absorber plate is replaced by
sixteen steel wire mesh layers, 0.18 x 0.18cm in cross section
opening and a 0.02cm in diameter. The wire mesh layers arranged in
three groups, first and second include 6 layers, while the third include
4 layers. All layers fixed in the duct parallel to the glazing and each
group separated from the others by wood frame thickness of 0.5cm to
reduce the pressure drop. The transverse fins arranged in a way to
force the air to flow through the bed like eight letter path with flow
depth 3cm. The proposed design has increased the heat transfer rate,
but on other hand causes a high pressure drop. The obtained results
show that, for air mass flow rate range between 0.011-0.036kg/s, the
thermal efficiency increases with increasing the air mass flow. The
maximum efficiency obtained is 65.6% for the mass flow rate of
0.036kg/s. Moreover, the temperature difference between the outlet
flow and the ambient temperature, ΔT, reduces as the air mass flow
rate increase. The maximum difference between the outlet and
ambient temperature obtained was 43°C for double pass for minimum
mass flow rate of 0.011kg/s. Comparison with a conventional solar
air heater collector shows a significantly development in the thermal
efficiency.
Abstract: The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.
Abstract: The technique of inducing micro ecosystem
restoration is one of aquatic ecology engineering methods used to
retrieve the polluted water. Batch scale study, pilot plant study, and
field study were carried out to observe the eutrophication using the
Inducing Ecology Restorative Symbiosis Agent (IERSA) consisting
mainly degraded products by using lactobacillus, saccharomycete,
and phycomycete. The results obtained from the experiments of the
batch scale and pilot plant study allowed us to development the
parameters for the field study. A pond, 5 m to the outlet of a lake,
with an area of 500 m2 and depth of 0.6-1.2 m containing about 500
tons of water was selected as a model. After the treatment with 10
mg IERSA/L water twice a week for 70 days, the micro restoration
mechanisms consisted of three stages (i.e., restoration, impact
maintenance, and ecology recovery experiment after impact). The
COD, TN, TKN, and chlorophyll a were reduced significantly in the
first week. Although the unexpected heavy rain and contaminate
from sewage system might slow the ecology restoration. However,
the self-cleaning function continued and the chlorophyll a reduced
for 50% in one month. In the 4th week, amoeba, paramecium, rotifer,
and red wriggle worm reappeared, and the number of fish flies
appeared up to1000 fish fries/m3. Those results proved that inducing
restorative mechanism can be applied to improve the eutrophication
and to control the growth of algae in the lakes by gaining the selfcleaning
through inducing and competition of microbes. The
situation for growth of fishes also can reach an excellent result due to
the improvement of water quality.
Abstract: A microchannel with two inlets and two outlets was tested as a potential reactor to carry out two-phase catalytic phase transfer reaction with phase separation at the exit of the microchannel. The catalytic phase transfer reaction between benzyl chloride and sodium sulfide was chosen as a model reaction. The effect of operational time on the conversion was studied. By utilizing a multiphase parallel flow inside the microchannel reactor with the aid of a guideline structure, the catalytic phase reaction followed by phase separation could be ensured. The organic phase could be separated completely from one exit and part of the aqueous phase was separated purely and could be reused with slightly affecting the catalytic phase transfer reaction.
Abstract: The paper presents a computational tool developed for
the evaluation of technical and economic advantages of an innovative
cleaning and conditioning technology of fluidized bed steam/oxygen
gasifiers outlet product gas. This technology integrates into a single
unit the steam gasification of biomass and the hot gas cleaning and
conditioning system. Both components of the computational tool,
process flowsheet and economic evaluator, have been developed
under IPSEpro software. The economic model provides information
that can help potential users, especially small and medium size
enterprises acting in the regenerable energy field, to decide the
optimal scale of a plant and to better understand both potentiality and
limits of the system when applied to a wide range of conditions.
Abstract: The operation performance of a valveless micro-pump
is strongly dependent on the shape of connected nozzle/diffuser and
Reynolds number. The aims of present work are to compare the
performance curves of micropump with the original straight
nozzle/diffuser and contoured nozzle/diffuser under different back
pressure conditions. The tested valveless micropumps are assembled
of five pieces of patterned PMMA plates with hot-embracing
technique. The structures of central chamber, the inlet/outlet
reservoirs and the connected nozzle/diffuser are fabricated with laser
cutting machine. The micropump is actuated with circular-type PZT
film embraced on the bottom of central chamber. The deformation of
PZT membrane with various input voltages is measured with a
displacement laser probe. A simple testing facility is also constructed
to evaluate the performance curves for comparison.
In order to observe the evaluation of low Reynolds number
multiple vortex flow patterns within the micropump during suction
and pumping modes, the unsteady, incompressible laminar
three-dimensional Reynolds-averaged Navier-Stokes equations are
solved. The working fluid is DI water with constant thermo-physical
properties. The oscillating behavior of PZT film is modeled with the
moving boundary wall in way of UDF program. With the dynamic
mesh method, the instants pressure and velocity fields are obtained
and discussed.Results indicated that the volume flow rate is not
monotony increased with the oscillating frequency of PZT film,
regardless of the shapes of nozzle/diffuser. The present micropump
can generate the maximum volume flow rate of 13.53 ml/min when
the operation frequency is 64Hz and the input voltage is 140 volts.
The micropump with contoured nozzle/diffuser can provide 7ml/min
flow rate even when the back pressure is up to 400 mm-H2O. CFD
results revealed that the flow central chamber was occupied with
multiple pairs of counter-rotating vortices during suction and
pumping modes. The net volume flow rate over a complete
oscillating periodic of PZT
Abstract: Resins are used in nuclear power plants for water
ultrapurification. Two approaches are considered in this work:
column experiments and simulations. A software called OPTIPUR
was developed, tested and used. The approach simulates the onedimensional
reactive transport in porous medium with convectivedispersive
transport between particles and diffusive transport within
the boundary layer around the particles. The transfer limitation in the
boundary layer is characterized by the mass transfer coefficient
(MTC). The influences on MTC were measured experimentally. The
variation of the inlet concentration does not influence the MTC; on
the contrary of the Darcy velocity which influences. This is consistent
with results obtained using the correlation of Dwivedi&Upadhyay.
With the MTC, knowing the number of exchange site and the relative
affinity, OPTIPUR can simulate the column outlet concentration
versus time. Then, the duration of use of resins can be predicted in
conditions of a binary exchange.