Effect of Blanching on the Quality of Microwave Vacuum Dried Dill (Anethum graveolens L.)

Dill (Anethum graveolens L.) is a popular herb used in many regions, including Baltic countries. Dill is widely used for flavoring foods and beverages due to its pleasant spicy aroma. The aim of this work was to determine the best blanching method for processing of dill prior to microwave vacuum drying based on sensory properties, color and volatile compounds in dried product. Two blanching mediums were used – water and steam, and for part of samples microwave pretreatment was additionally used. Evaluation of dried dill volatile aroma compounds, color changes and sensory attributes was performed. Results showed that blanching significantly influences the quality of dried dill. After evaluation of volatile aroma compounds, color and sensory properties of microwave vacuum dried dill, as the best method for dill pretreatment was established blanching at 90 °C for 30 s.

Field Investigation on Modification of Japanese Cedar Pollen Allergen in Urban Air-Polluted Area

Cry j 1 is a causative substance of Japanese cedar pollinosis, and it may deteriorate by Cry j 1 invasion to a lower respiratory tract. We observed airborne particles containing Cry j 1 by an immunofluorescence technique using a fluorescence microscope, and we clarified that Cry j 1 exist as aggregates of airborne fine particles (< 1.1 μm) in the urban atmosphere. Airborne Cry j 1 may react with air pollutants and be denature to a substance deteriorated Japanese cedar pollinosis. Therefore, we applied a sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) to evaluate a Cry j 1 reacted with various air pollutants by liquid phase reaction, and calculated kinetics constants of Cry j 1 extracted from pollens collected in various sites and airborne fine particles containing Cry j 1 by using a surface plasmon resonance (SPR) method. As a result, it is suggested that Cry j 1 may be denatured by air pollutants during the transportation to the urban atmosphere.

Sensory Evaluation of Cooked Sausages with Legumes Additive

In the meat processing industry the substitution of meat with non-meat ingredients is considered an important strategy for reducing overall production costs. The main purpose of the current research was to evaluate differences in physical-chemical composition of cooked sausage with different legumes additions. Peas (Pisum sativum), beans (Phaseolus vulgaris) and lentil (Lens culinaris) were used in preparation of sausages. The legumes at proportion of 20% of the total weight of meat were added in sausages. The whole ingredients were mixed, filled into casing, compressed, cooked and cooled. After storage the samples were sensory evaluated. The sensory evaluation was carried out using the nine point hedonic scale and line scale. Sausages without legumes flour was used as control sample. The main conclusion of the current research the legumes flour can be successfully used for cooked sausages production.

Opto-Mechanical Characterization of Aspheric Lenses from the Hybrid Method

Aspheric optical components are an alternative to the use of conventional lenses in the implementation of imaging systems for the visible range. Spherical lenses are capable of producing aberrations. Therefore, they are not able to focus all the light into a single point. Instead, aspherical lenses correct aberrations and provide better resolution even with compact lenses incorporating a small number of lenses. Metrology of these components is very difficult especially when the resolution requirements increase and insufficient or complexity of conventional tools requires the development of specific approaches to characterization. This work is part of the problem existed because the objectives are the study and comparison of different methods used to measure surface rays hybrid aspherical lenses.

Probability and Instruction Effects in Syllogistic Conditional Reasoning

The main aim of this study was to examine whether people understand indicative conditionals on the basis of syntactic factors or on the basis of subjective conditional probability. The second aim was to investigate whether the conditional probability of q given p depends on the antecedent and consequent sizes or derives from inductive processes leading to establish a link of plausible cooccurrence between events semantically or experientially associated. These competing hypotheses have been tested through a 3 x 2 x 2 x 2 mixed design involving the manipulation of four variables: type of instructions (“Consider the following statement to be true", “Read the following statement" and condition with no conditional statement); antecedent size (high/low); consequent size (high/low); statement probability (high/low). The first variable was between-subjects, the others were within-subjects. The inferences investigated were Modus Ponens and Modus Tollens. Ninety undergraduates of the Second University of Naples, without any prior knowledge of logic or conditional reasoning, participated in this study. Results suggest that people understand conditionals in a syntactic way rather than in a probabilistic way, even though the perception of the conditional probability of q given p is at least partially involved in the conditionals- comprehension. They also showed that, in presence of a conditional syllogism, inferences are not affected by the antecedent or consequent sizes. From a theoretical point of view these findings suggest that it would be inappropriate to abandon the idea that conditionals are naturally understood in a syntactic way for the idea that they are understood in a probabilistic way.

Numerical Solution of Linear Ordinary Differential Equations in Quantum Chemistry by Clenshaw Method

As we know, most differential equations concerning physical phenomenon could not be solved by analytical method. Even if we use Series Method, some times we need an appropriate change of variable, and even when we can, their closed form solution may be so complicated that using it to obtain an image or to examine the structure of the system is impossible. For example, if we consider Schrodinger equation, i.e., We come to a three-term recursion relations, which work with it takes, at least, a little bit time to get a series solution[6]. For this reason we use a change of variable such as or when we consider the orbital angular momentum[1], it will be necessary to solve. As we can observe, working with this equation is tedious. In this paper, after introducing Clenshaw method, which is a kind of Spectral method, we try to solve some of such equations.

Ultra-Precise Hybrid Lens Distortion Correction

A new hybrid method to realise high-precision distortion determination for optical ultra-precision 3D measurement systems based on stereo cameras using active light projection is introduced. It consists of two phases: the basic distortion determination and the refinement. The refinement phase of the procedure uses a plane surface and projected fringe patterns as calibration tools to determine simultaneously the distortion of both cameras within an iterative procedure. The new technique may be performed in the state of the device “ready for measurement" which avoids errors by a later adjustment. A considerable reduction of distortion errors is achieved and leads to considerable improvements of the accuracy of 3D measurements, especially in the precise measurement of smooth surfaces.

Development of a Microsensor to Minimize Post Cataract Surgery Complications

This paper presents design and characterization of a microaccelerometer designated for integration into cataract surgical probe to detect hardness of different eye tissues during cataract surgery. Soft posterior lens capsule of eye can be easily damaged in comparison with hard opaque lens since the surgeon can not see directly behind cutting needle during the surgery. Presence of microsensor helps the surgeon to avoid rupturing posterior lens capsule which if occurs leads to severe complications such as glaucoma, infection, or even blindness. The microsensor having overall dimensions of 480 μm x 395 μm is able to deliver significant capacitance variations during encountered vibration situations which makes it capable to distinguish between different types of tissue. Integration of electronic components on chip ensures high level of reliability and noise immunity while minimizes space and power requirements. Physical characteristics and results on performance testing, proves integration of microsensor as an effective tool to aid the surgeon during this procedure.

New Effective Strains of Bacteria Bacillus thuringiensis ssp. israelensis for Bloodsucking Mosquito Control

Five original strains of entomopathogenic bacteria with insecticidal activity against mosquito larvae of the genera Aedes, Culex and Anopheles have been isolated from natural conditions in Armenia and characterized. According to morphological, physiological and biochemical parameters, all isolates were identified as Bacillus thuringiensis spp. israelensis (Bti). High larvicidal activity has been showed by three strains Bti. These strains can be recommended for industrial production of bacterial preparations.

Evaluation of Some Chemical Parameters as Potential Determinants of Fresh Water Snails with Special Reference to Medically Important Snails in Egypt

Seasonal survey of freshwater snails in different water courses in Egypt during two successive years included 13 snail species. They represented by Biomphalaria alexandrina, Bulinus truncatus, Physa acuta, Helisoma duryi, Lymnaea natalensis, Planorbis pantries, Cleopatra bulimoides, Lanistes carinatus, Bellamya unicolor, Melanoides tuberculata, Theodoxus niloticus, Succinia cleopatra and Valvata nilotica. B. alexandrina was most abundant during autumn and spring represented by 26and14 snails/site, respectively. B. truncatus was most abundant during winter (7.7and3.6snails/site) of the two years, respectively. L. natalensis was represented by 7snails/site in summer. The tolerance of different snail species to the chemical elements was determined seasonally and correlated to their abundance. In spring, autumn and winter, B. alexandrina was significantly found to live under the highest level of Pb, Cd,Cu, Na, K and Ca concentrations than the other species (p

E-Business Security: Methodological Considerations

A great deal of research works in the field information systems security has been based on a positivist paradigm. Applying the reductionism concept of the positivist paradigm for information security means missing the bigger picture and thus, the lack of holism which could be one of the reasons why security is still overlooked, comes as an afterthought or perceived from a purely technical dimension. We need to reshape our thinking and attitudes towards security especially in a complex and dynamic environment such as e- Business to develop a holistic understanding of e-Business security in relation to its context as well as considering all the stakeholders in the problem area. In this paper we argue the suitability and need for more inductive interpretive approach and qualitative research method to investigate e-Business security. Our discussion is based on a holistic framework of enquiry, nature of the research problem, the underling theoretical lens and the complexity of e-Business environment. At the end we present a research strategy for developing a holistic framework for understanding of e-Business security problems in the context of developing countries based on an interdisciplinary inquiry which considers their needs and requirements.

Blinking Characteristics and Corneal Staining in Different Soft Lens Materials

Background Contact lens (CL) wear can cause changes in blinking and corneal staining. Aims and Objectives To determine the effects of CL materials (HEMA and SiHy) on spontaneous blink rate, blinking patterns and corneal staining after 2 months of wear. Methods Ninety subjects in 3 groups (control, HEMA and SiHy) were assessed at baseline and 2-months. Blink rate was recorded using a video camera. Blinking patterns were assessed with digital camera and slit lamp biomicroscope. Corneal staining was graded using IER grading scale Results There were no significant differences in all parameters at baseline. At 2 months, CL wearers showed significant increment in average blink rate (F1.626, 47.141 = 7.250, p = 0.003; F2,58 = 6.240, p = 0.004) and corneal staining (χ2 2, n=30 = 31.921, p < 0.001; χ2 2, n=30 = 26.909, p < 0.001). Conclusion Blinking characteristics and corneal staining were not influence by soft CL materials.

The Mechanistic Deconvolutive Image Sensor Model for an Arbitrary Pan–Tilt Plane of View

This paper presents a generalized form of the mechanistic deconvolution technique (GMD) to modeling image sensors applicable in various pan–tilt planes of view. The mechanistic deconvolution technique (UMD) is modified with the given angles of a pan–tilt plane of view to formulate constraint parameters and characterize distortion effects, and thereby, determine the corrected image data. This, as a result, does not require experimental setup or calibration. Due to the mechanistic nature of the sensor model, the necessity for the sensor image plane to be orthogonal to its z-axis is eliminated, and it reduces the dependency on image data. An experiment was constructed to evaluate the accuracy of a model created by GMD and its insensitivity to changes in sensor properties and in pan and tilt angles. This was compared with a pre-calibrated model and a model created by UMD using two sensors with different specifications. It achieved similar accuracy with one-seventh the number of iterations and attained lower mean error by a factor of 2.4 when compared to the pre-calibrated and UMD model respectively. The model has also shown itself to be robust and, in comparison to pre-calibrated and UMD model, improved the accuracy significantly.

A Semantic Recommendation Procedure for Electronic Product Catalog

To overcome the product overload of Internet shoppers, we introduce a semantic recommendation procedure which is more efficient when applied to Internet shopping malls. The suggested procedure recommends the semantic products to the customers and is originally based on Web usage mining, product classification, association rule mining, and frequently purchasing. We applied the procedure to the data set of MovieLens Company for performance evaluation, and some experimental results are provided. The experimental results have shown superior performance in terms of coverage and precision.

Basic Research for Distinguishing Small Retinal Hemorrhages from Dust Artifact by using Hue, Lightness, and Saturation Color Space

To distinguish small retinal hemorrhages in early diabetic retinopathy from dust artifacts, we analyzed hue, lightness, and saturation (HLS) color spaces. The fundus of 5 patients with diabetic retinopathy was photographed. For the initial experiment, we placed 4 different colored papers on the ceiling of a darkroom. Using each color, 10 fragments of house dust particles on a magnifier were photographed. The colored papers were removed, and 3 different colored light bulbs were suspended from the ceiling. Ten fragments of house dust particles on the camera-s object lens were photographed. We then constructed an experimental device that can photograph artificial eyes. Five fragments of house dust particles under the ocher fundus of the artificial eye were photographed. On analyzing HLS color space of the dust artifact, lightness and saturation were found to be highly sensitive. However, hue was not highly sensitive.

Development of an Infrared Thermography Method with CO2 Laser Excitation, Applied to Defect Detection in CFRP

This paper presents a NDT by infrared thermography with excitation CO2 Laser, wavelength of 10.6 μm. This excitation is the controllable heating beam, confirmed by a preliminary test on a wooden plate 1.2 m x 0.9 m x 1 cm. As the first practice, this method is applied to detecting the defect in CFRP heated by the Laser 300 W during 40 s. Two samples 40 cm x 40 cm x 4.5 cm are prepared, one with defect, another one without defect. The laser beam passes through the lens of a deviation device, and heats the samples placed at a determinate position and area. As a result, the absence of adhesive can be detected. This method displays prominently its application as NDT with the composite materials. This work gives a good perspective to characterize the laser beam, which is very useful for the next detection campaigns.

Telecommunications Access, Social Capital and Sustainable Development

This paper examines the role of telecommunications in sustainable development of urban, rural and remote communities in the Northern Territory of Australia through the theoretical lens of Social Capital. Social Capital is a relatively new construct and is rapidly gaining interest among policy makers, politicians and researchers as a means to both describe and understand social and economic development. Increasingly, the concept of Social Capital, as opposed to the traditional economic indicators, is seen as a more accurate measure of well-being. Whilst the essence of Social Capital is quality social relations, the concept intersects with telecommunications and Information Communications Technology (ICT) in a number of ways. The potential of ICT to disseminate information quickly, to reach vast numbers of people simultaneously and to include the previously excluded, is immense. However, the exact nature of the relationship is not clearly defined. This paper examines the nexus between social relations of mutual benefit, telecommunications access and sustainable development. A mixed methodological approach was used to test the hypothesis that No relationship exists between Social Capital and access to telecommunications services and facilities. Four communities, which included two urban, a rural and a remote Indigenous community in the Northern Territory of Australia are the focus of this research paper.

Speckle Characterization in Laser Projector Display

Speckle phenomena results from when coherent radiation is reflected from a rough surface. Characterizing the speckle strongly depends on the measurement condition and experimental setup. In this paper we report the experimental results produced with different parameters in the setup. We investigated the factors which affects the speckle contrast, such as, F-number, gamma value and exposure time of the camera, rather than geometric factors like the distance between the projector lens to the screen, the viewing distance, etc. The measurement results show that the speckle contrast decreases by decreasing F-number, by increasing gamma value, and slightly affects by exposure time of the camera and the gain value of the camera.

Voltage-Controllable Liquid Crystals Lens

This study investigates a voltage-controllable liquid crystals lens with a Fresnel zone electrode. When applying a proper voltage on the liquid crystal cell, a Fresnel-zone-distributed electric field is induced to direct liquid crystals aligned in a concentric structure. Owing to the concentrically aligned liquid crystals, a Fresnel lens is formed. We probe the Fresnel liquid crystal lens using a polarized incident beam with a wavelength of 632.8 nm, finding that the diffraction efficiency depends on the applying voltage. A remarkable diffraction efficiency of ~39.5 % is measured at the voltage of 0.9V. Additionally, a dual focus lens is fabricated by attaching a plane-convex lens to the Fresnel liquid crystals cell. The Fresnel LC lens and the dual focus lens may be applied for DVD/CD pick-up head, confocal microscopy system, or electrically-controlling optical systems.

Approximate Method of Calculation of Inviscid Hypersonic Flow

In the present work steady inviscid hypersonic flows are calculated by approximate Method. Maslens' inverse method is the chosen approximate method. For the inverse problem, parabolic shock shape is chosen for the two-dimensional flow, and the body shape and flow field are calculated using Maslen's method. For the axisymmetric inverse problem paraboloidal shock is chosen and the surface distribution of pressure is obtained.