Abstract: A traditional greenhouse is a metal frame agricultural building used for cultivation plants in a controlled environment isolated from external climatic changes. Using greenhouses in agriculture is an efficient way to reduce the water consumption, where agriculture field is considered the biggest water consumer world widely. Controlling greenhouse environment yields better productivity of plants but demands an increase of electric power. Although various control approaches have been used towards greenhouse automation, most of them are applied to traditional greenhouses with ventilation fans and/or evaporation cooling system. Such approaches are still demanding high energy and water consumption. The aim of this research is to develop a fuzzy control system that minimizes water and energy consumption by utilizing outside weather conditions and underground heat exchanger to maintain the optimum climate of the greenhouse. The proposed control system is implemented on an experimental model of thermally isolated greenhouse structure with dimensions of 6x5x2.8 meters. It uses fans for extracting heat from the ground heat exchanger system, motors for automatic open/close of the greenhouse windows and LED as lighting system. The controller is integrated also with environmental condition sensors. It was found that using the air-to-air horizontal ground heat exchanger with 90 mm diameter and 2 mm thickness placed 2.5 m below the ground surface results in decreasing the greenhouse temperature of 3.28 ˚C which saves around 3 kW of consumed energy. It also eliminated the water consumption needed in evaporation cooling systems which are traditionally used for cooling the greenhouse environment.
Abstract: In this study, a field experiment and performance analysis of air-tunnel heat exchanger integrated with water-filled raft foundation of residential building were performed. In order to obtain better performance, conventional applications of air-tunnel inevitably have high initial cost or issues about insufficient installation space. To improve the feasibility of air tunnel heat exchanger in high-density housing, an integrated system consisting of air pipes immersed in the water-filled raft foundation was presented, taking advantage of immense amount of water and relatively stable temperature in raft foundation of building. The foundation-integrated air tunnel was applied to a residential building located in Yilan, Taiwan, and its thermal performance was measured in the field experiment. The results indicated that the cooling potential of integrated system was close to the potential of soil-based EAHE at 2 m depth or deeper. An analytical model based on thermal resistance method was validated by measurement results, and was used to carry out the dimensioning of foundation-integrated air tunnel. The discrepancies between calculated value and measured data were less than 2.7%. In addition, the return-on-investment with regard to thermal performance and economics of the application was evaluated. Because the installation for air tunnel is scheduled in the building foundation construction, the utilization of integrated system spends less construction cost compare to the conventional earth-air tunnel.
Abstract: The thermo-mechanical behaviour of concrete energy
pile foundations with different single and double U-tube shapes
incorporated was analysed using the Comsol Multi-physics package.
For the analysis, a 3D numerical model in real scale of the concrete
pile and surrounding soil was simulated regarding actual operation of
ground heat exchangers (GHE) and the surrounding ambient
temperature. Based on initial ground temperature profile measured in
situ, tube inlet temperature was considered to range from 6oC to 0oC
(during the contraction process) over a 30-day period. Extra thermal
stresses and deformations were calculated during the simulations and
differences arising from the use of two different systems (single-tube
and double-tube) were analysed. The results revealed no significant
difference for extra thermal stresses at the centre of the pile in either
system. However, displacements over the pile length were found to
be up to 1.5-fold higher in the double-tube system than the singletube
system.
Abstract: Ground Coupled Heat Pumps (GCHPs) exploit effectively the heat capacity of the ground, with the use of Ground Heat Exchangers (GHE). Depending on the mode of operation of the GCHPs, GHEs dissipate or absorb heat from the ground. For sizing the GHE the thermal properties of the ground need to be known. This paper gives information about the density, thermal conductivity, specific heat and thermal diffusivity of various lithologies encountered in Cyprus with various relations between these properties being examined through comparison and modeling. The results show that the most important correlation is the one encountered between thermal conductivity and thermal diffusivity with both properties showing similar response to the inlet and outlet flow temperature of vertical and horizontal heat exchangers.
Abstract: Ground-source heat pumps achieve higher efficiencies
than conventional air-source heat pumps because they exchange heat
with the ground that is cooler in summer and hotter in winter than the
air environment. Earth heat exchangers are essential parts of the
ground-source heat pumps and the accurate prediction of their
performance is of fundamental importance. This paper presents the
development and validation of a numerical model through an
incompressible fluid flow, for the simulation of energy and
temperature changes in and around a U-tube borehole heat
exchanger. The FlexPDE software is used to solve the resulting
simultaneous equations that model the heat exchanger. The validated
model (through a comparison with experimental data) is then used to
extract conclusions on how various parameters like the U-tube
diameter, the variation of the ground thermal conductivity and
specific heat and the borehole filling material affect the temperature
of the fluid.
Abstract: In this paper, the feasibility study of using a hybrid
system of ground heat exchangers (GHE) and direct evaporative
cooling system in arid weather condition has been performed. The
model is applied for Yazd and Kerman, two cities with arid weather
condition in Iran. The system composed of three sections: Ground-
Coupled-Circuit (GCC), Direct Evaporative Cooler (DEC) and
Cooling Coil Unite (CCU). The GCC provides the necessary precooling
for DEC. The GCC includes four vertical GHE which are
designed in series configuration. Simulation results show that
hybridization of GCC and DEC could provide comfort condition
whereas DEC alone did not. Based on the results the cooling
effectiveness of a hybrid system is more than unity. Thus, this novel
hybrid system could decrease the air temperature below the ambient
wet-bulb temperature. This environmentally clean and energy
efficient system can be considered as an alternative to the mechanical
vapor compression systems.