Abstract: The thermo-mechanical behaviour of concrete energy
pile foundations with different single and double U-tube shapes
incorporated was analysed using the Comsol Multi-physics package.
For the analysis, a 3D numerical model in real scale of the concrete
pile and surrounding soil was simulated regarding actual operation of
ground heat exchangers (GHE) and the surrounding ambient
temperature. Based on initial ground temperature profile measured in
situ, tube inlet temperature was considered to range from 6oC to 0oC
(during the contraction process) over a 30-day period. Extra thermal
stresses and deformations were calculated during the simulations and
differences arising from the use of two different systems (single-tube
and double-tube) were analysed. The results revealed no significant
difference for extra thermal stresses at the centre of the pile in either
system. However, displacements over the pile length were found to
be up to 1.5-fold higher in the double-tube system than the singletube
system.
Abstract: Ground Coupled Heat Pumps (GCHPs) exploit effectively the heat capacity of the ground, with the use of Ground Heat Exchangers (GHE). Depending on the mode of operation of the GCHPs, GHEs dissipate or absorb heat from the ground. For sizing the GHE the thermal properties of the ground need to be known. This paper gives information about the density, thermal conductivity, specific heat and thermal diffusivity of various lithologies encountered in Cyprus with various relations between these properties being examined through comparison and modeling. The results show that the most important correlation is the one encountered between thermal conductivity and thermal diffusivity with both properties showing similar response to the inlet and outlet flow temperature of vertical and horizontal heat exchangers.
Abstract: In this paper, the feasibility study of using a hybrid
system of ground heat exchangers (GHE) and direct evaporative
cooling system in arid weather condition has been performed. The
model is applied for Yazd and Kerman, two cities with arid weather
condition in Iran. The system composed of three sections: Ground-
Coupled-Circuit (GCC), Direct Evaporative Cooler (DEC) and
Cooling Coil Unite (CCU). The GCC provides the necessary precooling
for DEC. The GCC includes four vertical GHE which are
designed in series configuration. Simulation results show that
hybridization of GCC and DEC could provide comfort condition
whereas DEC alone did not. Based on the results the cooling
effectiveness of a hybrid system is more than unity. Thus, this novel
hybrid system could decrease the air temperature below the ambient
wet-bulb temperature. This environmentally clean and energy
efficient system can be considered as an alternative to the mechanical
vapor compression systems.