Abstract: In general, codes and regulations consider seismic
loads only for completed structures of the bridges while, evaluation
of incomplete structure of bridges, especially those constructed by
free cantilever method, under these loads is also of great importance.
Hence, this research tried to study the behavior of incomplete
structure of common bridge type (box girder bridge), in construction
phase under vertical seismic loads. Subsequently, the paper provided
suitable guidelines and solutions to resist this destructive
phenomenon. Research results proved that use of preventive methods
can significantly reduce the stresses resulted from vertical seismic
loads in box cross sections to an acceptable range recommended by
design codes.
Abstract: The thermo-mechanical behaviour of concrete energy
pile foundations with different single and double U-tube shapes
incorporated was analysed using the Comsol Multi-physics package.
For the analysis, a 3D numerical model in real scale of the concrete
pile and surrounding soil was simulated regarding actual operation of
ground heat exchangers (GHE) and the surrounding ambient
temperature. Based on initial ground temperature profile measured in
situ, tube inlet temperature was considered to range from 6oC to 0oC
(during the contraction process) over a 30-day period. Extra thermal
stresses and deformations were calculated during the simulations and
differences arising from the use of two different systems (single-tube
and double-tube) were analysed. The results revealed no significant
difference for extra thermal stresses at the centre of the pile in either
system. However, displacements over the pile length were found to
be up to 1.5-fold higher in the double-tube system than the singletube
system.