Abstract: This paper presents the observations from a series of shaking-table tests done on a 1:1 scaled confined masonry wall model, with opening for a door – specimens CMDuS (confined masonry wall with opening for a door before strengthening) and CMDS (confined masonry wall with opening for a door after strengthening). Frequency and stiffness changes before and after GFRP (Glass Fiber Reinforced Plastic) wall strengthening are analyzed. Definition of dynamic properties of the models was the first step of the experimental testing, which enabled acquiring important information about the achieved stiffness (natural frequencies) of the model. The natural frequency was defined in the Y direction of the model by applying resonant frequency search tests. It is important to mention that both specimens CMDuS and CMDS are subjected to the same effects. The tests are realized in the laboratory of the Institute of Earthquake Engineering and Engineering Seismology (IZIIS), Skopje. The specimens were examined separately on the shaking table, with uniaxial, in-plane excitation. After testing, samples were strengthened with GFRP and re-tested. The initial frequency of the undamaged model CMDuS is 13.55 Hz, while at the end of the testing, the frequency decreased to 6.38 Hz. This emphasizes the reduction of the initial stiffness of the model due to damage, especially in the masonry and tie-beam to tie-column connection. After strengthening of the damaged wall, the natural frequency increases to 10.89 Hz. This highlights the beneficial effect of the strengthening. After completion of dynamic testing at CMDS, the natural frequency is reduced to 6.66 Hz.
Abstract: Three structure-dependent integration methods have been developed for solving equations of motion, which are second-order ordinary differential equations, for structural dynamics and earthquake engineering applications. Although they generally have the same numerical properties, such as explicit formulation, unconditional stability and second-order accuracy, a different performance is found in solving the free vibration response to either linear elastic or nonlinear systems with high frequency modes. The root cause of this different performance in the free vibration responses is analytically explored herein. As a result, it is verified that a weak instability is responsible for the different performance of the integration methods. In general, a weak instability will result in an inaccurate solution or even numerical instability in the free vibration responses of high frequency modes. As a result, a weak instability must be prohibited for time integration methods.
Abstract: It is commonly observed that aftershocks follow the mainshock. Aftershocks continue over a period of time with a decreasing frequency and typically there is not sufficient time for repair and retrofit between a mainshock–aftershock sequence. Usually, aftershocks are smaller in magnitude; however, aftershock ground motion characteristics such as the intensity and duration can be greater than the mainshock due to the changes in the earthquake mechanism and location with respect to the site. The seismic performance of slopes is typically evaluated based on the sliding displacement predicted to occur along a critical sliding surface. Various empirical models are available that predict sliding displacement as a function of seismic loading parameters, ground motion parameters, and site parameters but these models do not include the aftershocks. The seismic risks associated with the post-mainshock slopes ('damaged slopes') subjected to aftershocks is significant. This paper extends the empirical sliding displacement models for flexible slopes subjected to earthquake mainshock-aftershock sequences (a multi hazard approach). A dataset was developed using 144 pairs of as-recorded mainshock-aftershock sequences using the Pacific Earthquake Engineering Research Center (PEER) database. The results reveal that the combination of mainshock and aftershock increases the seismic demand on slopes relative to the mainshock alone; thus, seismic risks are underestimated if aftershocks are neglected.
Abstract: In this paper, the results of experimental tests
performed on a Helical Wire Rope Isolator (HWRI) are presented in
order to describe the dynamic and static behavior of the selected
metal device in three different displacements ranges, namely small,
relatively large, and large displacements ranges, without and under
the effect of a vertical load. A testing machine, allowing to apply
horizontal displacement or load histories to the tested bearing with a
constant vertical load, has been adopted to perform the dynamic and
static tests. According to the experimental results, the dynamic
behavior of the tested device depends on the applied displacement
amplitude. Indeed, the HWRI displays a softening and a hardening
stiffness at small and relatively large displacements, respectively, and
a stronger nonlinear stiffening behavior at large displacements.
Furthermore, the experimental tests reveal that the application of a
vertical load allows to have a more flexible device with higher
damping properties and that the applied vertical load affects much
less the dynamic response of the metal device at large displacements.
Finally, a decrease in the static to dynamic effective stiffness ratio
with increasing displacement amplitude has been observed.
Abstract: In this paper, a one-dimensional (1d) Parallel Elasto-
Plastic Model (PEPM), able to simulate the uniaxial dynamic
behavior of seismic isolators having a continuously decreasing
tangent stiffness with increasing displacement, is presented. The
parallel modeling concept is applied to discretize the continuously
decreasing tangent stiffness function, thus allowing to simulate the
dynamic behavior of seismic isolation bearings by putting linear
elastic and nonlinear elastic-perfectly plastic elements in parallel. The
mathematical model has been validated by comparing the
experimental force-displacement hysteresis loops, obtained testing a
helical wire rope isolator and a recycled rubber-fiber reinforced
bearing, with those predicted numerically. Good agreement between
the simulated and experimental results shows that the proposed
model can be an effective numerical tool to predict the forcedisplacement
relationship of seismic isolators within relatively large
displacements. Compared to the widely used Bouc-Wen model, the
proposed one allows to avoid the numerical solution of a first order
ordinary nonlinear differential equation for each time step of a
nonlinear time history analysis, thus reducing the computation effort,
and requires the evaluation of only three model parameters from
experimental tests, namely the initial tangent stiffness, the asymptotic
tangent stiffness, and a parameter defining the transition from the
initial to the asymptotic tangent stiffness.
Abstract: The solution of the nonlinear dynamic equilibrium equations of base-isolated structures adopting a conventional monolithic solution approach, i.e. an implicit single-step time integration method employed with an iteration procedure, and the use of existing nonlinear analytical models, such as differential equation models, to simulate the dynamic behavior of seismic isolators can require a significant computational effort. In order to reduce numerical computations, a partitioned solution method and a one dimensional nonlinear analytical model are presented in this paper. A partitioned solution approach can be easily applied to base-isolated structures in which the base isolation system is much more flexible than the superstructure. Thus, in this work, the explicit conditionally stable central difference method is used to evaluate the base isolation system nonlinear response and the implicit unconditionally stable Newmark’s constant average acceleration method is adopted to predict the superstructure linear response with the benefit in avoiding iterations in each time step of a nonlinear dynamic analysis. The proposed mathematical model is able to simulate the dynamic behavior of seismic isolators without requiring the solution of a nonlinear differential equation, as in the case of widely used differential equation model. The proposed mixed explicit-implicit time integration method and nonlinear exponential model are adopted to analyze a three dimensional seismically isolated structure with a lead rubber bearing system subjected to earthquake excitation. The numerical results show the good accuracy and the significant computational efficiency of the proposed solution approach and analytical model compared to the conventional solution method and mathematical model adopted in this work. Furthermore, the low stiffness value of the base isolation system with lead rubber bearings allows to have a critical time step considerably larger than the imposed ground acceleration time step, thus avoiding stability problems in the proposed mixed method.
Abstract: Predicting the collapse potential of a structure during
earthquakes is an important issue in earthquake engineering. Many
researchers proposed different methods to assess the collapse
potential of structures under the effect of strong ground motions.
However most of them did not consider degradation and softening
effect in hysteretic behavior. In this study, collapse potential of
SDOF systems caused by dynamic instability with stiffness and
strength degradation has been investigated. An equation was
proposed for the estimation of collapse period of SDOF system which
is a limit value of period for dynamic instability. If period of the
considered SDOF system is shorter than the collapse period then the
relevant system exhibits dynamic instability and collapse occurs.
Abstract: A key issue in seismic risk analysis within the context
of Performance-Based Earthquake Engineering is the evaluation of
the expected seismic damage of structures under a specific
earthquake ground motion. The assessment of the seismic
performance strongly depends on the choice of the seismic Intensity
Measure (IM), which quantifies the characteristics of a ground
motion that are important to the nonlinear structural response. Several
conventional IMs of ground motion have been used to estimate their
damage potential to structures. Yet, none of them has been proved to
be able to predict adequately the seismic damage. Therefore,
alternative, scalar intensity measures, which take into account not
only ground motion characteristics but also structural information
have been proposed. Some of these IMs are based on integration of
spectral values over a range of periods, in an attempt to account for
the information that the shape of the acceleration, velocity or
displacement spectrum provides. The adequacy of a number of these
IMs in predicting the structural damage of 3D R/C buildings is
investigated in the present paper. The investigated IMs, some of
which are structure specific and some are non structure-specific, are
defined via integration of spectral values. To achieve this purpose
three symmetric in plan R/C buildings are studied. The buildings are
subjected to 59 bidirectional earthquake ground motions. The two
horizontal accelerograms of each ground motion are applied along
the structural axes. The response is determined by nonlinear time
history analysis. The structural damage is expressed in terms of the
maximum interstory drift as well as the overall structural damage
index. The values of the aforementioned seismic damage measures
are correlated with seven scalar ground motion IMs. The comparative
assessment of the results revealed that the structure-specific IMs
present higher correlation with the seismic damage of the three
buildings. However, the adequacy of the IMs for estimation of the
structural damage depends on the response parameter adopted.
Furthermore, it was confirmed that the widely used spectral
acceleration at the fundamental period of the structure is a good
indicator of the expected earthquake damage level.
Abstract: A scheme integrated with deterministic–stochastic subspace system identification and the method of damage localization vector is proposed in this study for damage detection of structures based on seismic response data. A series of shaking table tests using a five-storey steel frame has been conducted in National Center for Research on Earthquake Engineering (NCREE), Taiwan. Damage condition is simulated by reducing the cross-sectional area of some of the columns at the bottom. Both single and combinations of multiple damage conditions at various locations have been considered. In the system identification analysis, either full or partial observation conditions have been taken into account. It has been shown that the damaged stories can be identified from global responses of the structure to earthquakes if sufficiently observed. In addition to detecting damage(s) with respect to the intact structure, identification of new or extended damages of the as-damaged (ill-conditioned) counterpart has also been studied. The proposed scheme proves to be effective.
Abstract: Widespread use of response spectra in seismic design and evaluation of different types of structures makes them one of the most important seismic inputs. This importance urges the local design codes to adapt precise data based on updated information about the recent major earthquakes happened and also localized geotechnical data. In this regard, this paper derives the response spectra with a geotechnical approach for various scenarios coming from the recent major earthquakes happened in Iran for different types of hard soils, and compares the results to the corresponding spectra from the current seismic code. This comparison implies the need for adapting new design spectra for seismic design, because of major differences in the frequency domains and amplifications.
Abstract: In order to upgrade the seismic resistibility of structures and enhance the functionality of an isolator, a new base isolator called the multiple trench friction pendulum system (MTFPS) is proposed in this study. The proposed MTFPS isolator is composed of a trench concave surface and several intermediate sliding plates in two orthogonal directions. Mathematical formulations have been derived to examine the characteristics of the proposed MTFPS isolator possessing multiple intermediate sliding plates. By means of mathematical formulations, it can be inferred that the natural period and damping effect of the MTFPS isolator with several intermediate sliding plates can be altered continually and controllably during earthquakes. Furthermore, results obtained from shaking table tests demonstrate that the proposed isolator provides good protection to structures for prevention of damage from strong earthquakes.