Abstract: Background: Breast cancer is the leading cause of death for women around the world. Screening mammography is the reference examination, due to its sensitivity for detecting small lesions and micro-calcifications. Therefore, it is essential to ensure quality mammographic examinations with the most optimal dose. These conditions depend on the choice of exposure parameters. Clinically, practices must be evaluated in order to determine the most appropriate exposure parameters. Material and Methods: We performed our measurements on a mobile mammography unit (PLANMED Sofie-classic.) in Morocco. A solid dosimeter (AGMS Radcal) and a MTM 100 phantom allow to quantify the delivered dose and the image quality. For image quality assessment, scores are defined by the rate of visible inserts (MTM 100 phantom), obtained and compared for each acquisition. Results: The results show that the parameters of the mammography unit on which we have made our measurements can be improved in order to offer a better compromise between image quality and breast dose. The last one can be reduced up from 13.27% to 22.16%, while preserving comparable image quality.
Abstract: The estimation of accumulated radiation doses in people professionally exposed to ionizing radiation was performed using methods of biological (chromosomal aberrations frequency in lymphocytes) and physical (radionuclides analysis in urine, whole-body radiation meter, individual thermoluminescent dosimeters) dosimetry. A group of 84 "A" category employees after their work in the territory of former Semipalatinsk test site (Kazakhstan) was investigated. The dose rate in some funnels exceeds 40 μSv/h. After radionuclides determination in urine using radiochemical and WBC methods, it was shown that the total effective dose of personnel internal exposure did not exceed 0.2 mSv/year, while an acceptable dose limit for staff is 20 mSv/year. The range of external radiation doses measured with individual thermo-luminescent dosimeters was 0.3-1.406 µSv. The cytogenetic examination showed that chromosomal aberrations frequency in staff was 4.27±0.22%, which is significantly higher than at the people from non-polluting settlement Tausugur (0.87±0.1%) (р ≤ 0.01) and citizens of Almaty (1.6±0.12%) (р≤ 0.01). Chromosomal type aberrations accounted for 2.32±0.16%, 0.27±0.06% of which were dicentrics and centric rings. The cytogenetic analysis of different types group radiosensitivity among «professionals» (age, sex, ethnic group, epidemiological data) revealed no significant differences between the compared values. Using various techniques by frequency of dicentrics and centric rings, the average cumulative radiation dose for group was calculated, and that was 0.084-0.143 Gy. To perform comparative individual dosimetry using physical and biological methods of dose assessment, calibration curves (including own ones) and regression equations based on general frequency of chromosomal aberrations obtained after irradiation of blood samples by gamma-radiation with the dose rate of 0,1 Gy/min were used. Herewith, on the assumption of individual variation of chromosomal aberrations frequency (1–10%), the accumulated dose of radiation varied 0-0.3 Gy. The main problem in the interpretation of individual dosimetry results is reduced to different reaction of the objects to irradiation - radiosensitivity, which dictates the need of quantitative definition of this individual reaction and its consideration in the calculation of the received radiation dose. The entire examined contingent was assigned to a group based on the received dose and detected cytogenetic aberrations. Radiosensitive individuals, at the lowest received dose in a year, showed the highest frequency of chromosomal aberrations (5.72%). In opposite, radioresistant individuals showed the lowest frequency of chromosomal aberrations (2.8%). The cohort correlation according to the criterion of radio-sensitivity in our research was distributed as follows: radio-sensitive (26.2%) — medium radio-sensitivity (57.1%), radioresistant (16.7%). Herewith, the dispersion for radioresistant individuals is 2.3; for the group with medium radio-sensitivity — 3.3; and for radio-sensitive group — 9. These data indicate the highest variation of characteristic (reactions to radiation effect) in the group of radio-sensitive individuals. People with medium radio-sensitivity show significant long-term correlation (0.66; n=48, β ≥ 0.999) between the values of doses defined according to the results of cytogenetic analysis and dose of external radiation obtained with the help of thermoluminescent dosimeters. Mathematical models based on the type of violation of the radiation dose according to the professionals radiosensitivity level were offered.
Abstract: In this paper, the authors propose a personal
wearable directionally-sensitive radiation dosimeter using multiple
semiconductor CdZnTe detectors. The proposed dosimeter not only
measures the real-time dose rate but also provide the direction of the
radioactive source. A linear relationship between radioactive source
direction and the radiation intensity measured by each detectors is
established and an equation to determine the source direction is
derived by the authors. The efficiency and accuracy of the proposed
dosimeter is verified by simulation using Geant4 package. Results
have indicated that in a measurement duration of about 7 seconds,
the proposed dosimeter was able to estimate the direction of a 10μCi
137/55Cs radioactive source to within 2 degrees.
Abstract: The ionizing radiations cause different kinds of damages in electronic components. MOSFETs, most common transistors in today’s digital and analog circuits, are severely sensitive to TID damage. In this work, the threshold voltage shift of CD4007 device, which is an integrated circuit including P-channel and N-channel MOS transistors, was investigated for low dose gamma irradiation under different gate bias voltages. We used linear extrapolation method to extract threshold voltage from ID-VG characteristic curve. The results showed that the threshold voltage shift was approximately 27.5 mV/Gy for N-channel and 3.5 mV/Gy for P-channel transistors at the gate bias of |9 V| after irradiation by Co-60 gamma ray source. Although the sensitivity of the devices under test were strongly dependent to biasing condition and transistor type, the threshold voltage shifted linearly versus accumulated dose in all cases. The overall results show that the application of CD4007 as an electronic buffer in a radiation therapy system is limited by TID damage. However, this integrated circuit can be used as a cheap and sensitive radiation dosimeter for accumulated dose measurement in radiation therapy systems.
Abstract: Extrapolation chambers were designed to be used as primary standard dosimeter for measuring absorbed dose in a medium in beta radiation and low energy x-rays. The International Organization for Standardization established series of reference x-radiation for calibrating and determining the energy dependence of dosimeters that are to be reproduced in metrology laboratories. Standardization of the low energy x-ray beams with tube potential lower than 30 kV may be affected by the instrument used for dosimetry. In this work, parameters of a 23392 model PTW extrapolation chamber were determined aiming its use in low energy x-ray beams as a reference instrument.
Abstract: Ionizing radiation can cause a drastic change in the physical and chemical properties of the material exposed. Numerous medical devices are sterilized by ionizing radiation. In the current research paper, an attempt was made to develop precise and inexpensive polymeric film dosimeter which can be used for controlling radiation dosage. Polymeric film containing (pH sensitive dye) indicator dye Bromophenol blue (BPB) was casted to check the effect of Gamma radiation on its optical and physical properties. The film was exposed to gamma radiation at 4 kGy/hr in the range of 0 to 300 kGy at an interval of 50 kGy. Release of vinyl acetate from an emulsion on high radiation reacts with the BPB fading the color of the film from blue to light blue and then finally colorless, indicating a change in pH from basic to acidic form. The change was characterized by using CIE l*a*b*, ultra-violet spectroscopy and FT-IR respectively.
Abstract: Radiation exposure to the patient's family members is one of the major concerns during thyroid cancer radionuclide therapy. The aim of this study was to measure the total effective dose of the family members by means of thermoluminescence personal dosimeter, and compare with those calculated by analytical methods. Eighty-five adult family members of fifty-one patients volunteered to participate in this research study. Considering the minimum and maximum range of dose rate from 15 µsv/h to 120 µsv/h at patients' release time, the calculated mean and median dose values of family members were 0.45 mSv and 0.28 mSv, respectively. Moreover, almost all family members’ doses were measured to be less than the dose constraint of 5 mSv recommended by Basic Safety Standards. Considering the influence parameters such as patient dose rate and administrated activity, the total effective doses of family members were calculated by TEDE and NRC formulas and compared with those of experimental results. The results indicated that, it is fruitful to use the quantitative calculations for releasing patients treated with I-131 and correct estimation of patients' family doses.
Abstract: In this study three commercial semiconductor devices
were characterized in the laboratory for computed tomography
dosimetry: one photodiode and two phototransistors. It was evaluated
four responses to the irradiation: dose linearity, energy dependence,
angular dependence and loss of sensitivity after X ray exposure. The
results showed that the three devices have proportional response with
the air kerma; the energy dependence displayed for each device
suggests that some calibration factors would be applied for each one;
the angular dependence showed a similar pattern among the three
electronic components. In respect to the fourth parameter analyzed,
one phototransistor has the highest sensitivity however it also showed
the greatest loss of sensitivity with the accumulated dose. The
photodiode was the device with the smaller sensitivity to radiation,
on the other hand, the loss of sensitivity after irradiation is negligible.
Since high accuracy is a desired feature for a dosimeter, the
photodiode can be the most suitable of the three devices for
dosimetry in tomography. The phototransistors can also be used for
CT dosimetry, however it would be necessary a correction factor due
to loss of sensitivity with accumulated dose.
Abstract: To investigate the applicability of the EDR-2 film for
clinical radiation dosimetry, percentage depth-doses, profiles and
distributions in open and dynamically wedged fields were measured
using film and compared with data from a Treatment Planning
system.The validity of the EDR2 film to measure dose in a plane
parallel to the beam was tested by irradiating 10 cm×10 cm and 4
cm×4 cm fields from a Siemens, primus linac with a 6MV beam and
a source-to-surface distance of 100 cm. The film was placed
Horizontally between solid water phantom blocks and marked
with pin holes at a depth of 10 cm from the incident beam surface.
The film measurement results, in absolute dose, were compared with
ion chamber measurements using a Welhoffer scanning water tank
system and Treatment Planning system. Our results indicate a
maximum underestimate of calculated dose of 8 % with Treatment
Planning system.
Abstract: The Brazilian legislation has only established
diagnostic reference levels (DRLs) in terms of Multiple Scan
Average Dose (MSAD) as a quality control parameter for computed
tomography (CT) scanners. Compliance with DRLs can be verified
by measuring the Computed Tomography Kerma Index (Ca,100) with
a pencil ionization chamber or by obtaining the kerma distribution in
CT scans with radiochromic films or rod shape lithium fluoride
termoluminescent dosimeters (TLD-100). TL dosimeters were used
to record kerma profiles and to determine MSAD values of a Bright
Speed model GE CT scanner. Measurements were done with
radiochromic films and TL dosimeters distributed in cylinders
positioned in the center and in four peripheral bores of a standard
polymethylmethacrylate (PMMA) body CT dosimetry phantom.
Irradiations were done using a protocol for adult chest. The
maximum values were found at the midpoint of the longitudinal axis.
The MSAD values obtained with three dosimetric techniques were
compared.
Abstract: Raman spectroscopy are used to characterize the
chemical changes in normoxic polyhydroxyethylacrylate gel
dosimeter (PHEA) induced by radiation. Irradiations in the low dose
region are performed and the polymerizations of PHEA gels are
monitored by the observing the changes of Raman shift intensity of
the carbon covalent bond of PHEA originated from both monomer
and the cross-linker. The variation in peak intensities with absorbed
dose was observed. As the dose increase, the peak intensities of
covalent bond of carbon in the polymer gels decrease. This point out
that the amount of absorbed dose affect the polymerization of
polymer gels. As the absorbed dose increase, the polymerizations
also increase. Results verify that PHEA gel dosimeters are sensitive
even in lower dose region.