Abstract: In this paper, we propose an efficient signal detector that switches M parameter of QRD-M detection scheme is proposed for MIMO-OFDM system. The proposed detection scheme calculates the threshold by 1-norm condition number and then switches M parameter of QRD-M detection scheme according to channel information. If channel condition is bad, the parameter M is set to high value to increase the accuracy of detection. If channel condition is good, the parameter M is set to low value to reduce complexity of detection. Therefore, the proposed detection scheme has better tradeoff between BER performance and complexity than the conventional detection scheme. The simulation result shows that the complexity of proposed detection scheme is lower than QRD-M detection scheme with similar BER performance.
Abstract: The study focuses to investigate the thermal response of delaminations and develop mathematical models using numerical results to obtain the optimum heat requirement and time to identify delaminations in GLARE type of Fibre Metal Laminates (FML) in both reflection mode and through-transmission (TT) mode of step pulsed active thermography (SPAT) method in the type of nondestructive testing and evaluation (NDTE) technique. The influence of applied heat flux and time on various sizes and depth of delaminations in FML is analyzed to investigate the thermal response through numerical simulations. A finite element method (FEM) is applied to simulate SPAT through ANSYS software based on 3D transient heat transfer principle with the assumption of reflection mode and TT mode of observation individually.
The results conclude that the numerical approach based on SPAT in reflection mode is more suitable for analysing smaller size of near-surface delaminations located at the thermal stimulator side and TT mode is more suitable for analysing smaller size of deeper delaminations located far from thermal stimulator side or near thermal detector/Infrared camera side. The mathematical models provide the optimum q and T at the required MRTD to identify unidentified delamination 7 with 25015.0022W/m2 at 2.531sec and delamination 8 with 16663.3356 W/m2 at 1.37857sec in reflection mode. In TT mode, the delamination 1 with 34954W/m2 at 13.0399sec, delamination 2 with 20002.67W/m2 at 1.998sec and delamination 7 with 20010.87 W/m2 at 0.6171sec could be identified.
Abstract: In Pharmaceutical industries, it is very important to remove drug residues from the equipment and areas used. The cleaning procedure must be validated, so special attention must be devoted to the methods used for analysis of trace amounts of drugs. A rapid, sensitive and specific reverse phase ultra performance liquid chromatographic (UPLC) method was developed for the quantitative determination of Albendazole in cleaning validation swab samples. The method was validated using an ACQUITY HSS C18, 50 x 2.1mm, 1.8μ column with a isocratic mobile phase containing a mixture of 1.36g of Potassium dihydrogenphosphate in 1000mL MilliQ water, 2mL of triethylamine and pH adjusted to 2.3 ± 0.05 with ortho-phosphoric acid, Acetonitrile and Methanol (50:40:10 v/v). The flow rate of the mobile phase was 0.5 mL min-1 with a column temperature of 350C and detection wavelength at 254nm using PDA detector. The injection volume was 2µl. Cotton swabs, moisten with acetonitrile were used to remove any residue of drug from stainless steel, teflon, rubber and silicon plates which mimic the production equipment surface and the mean extraction-recovery was found to be 91.8. The selected chromatographic condition was found to effectively elute Albendazole with retention time of 0.67min. The proposed method was found to be linear over the range of 0.2 to 150µg/mL and correlation coefficient obtained is 0.9992. The proposed method was found to be accurate, precise, reproducible and specific and it can also be used for routine quality control analysis of these drugs in biological samples either alone or in combined pharmaceutical dosage forms.
Abstract: Characteristics of MSM photodetector based on a porous In0.08Ga0.92N thin film were reported. Nanoporous structures of n-type In0.08Ga0.92N/AlN/Si thin films were synthesized by photoelectrochemical (PEC) etching at a ratio of 1:4 of HF:C2H5OH solution for 15min. The structural and optical properties of pre- and post-etched thin films were investigated. Field emission scanning electron microscope and atomic force microscope images showed that the pre-etched thin film has a sufficiently smooth surface over a large region and the roughness increased for porous film. Blue shift has been observed in photoluminescence emission peak at 300 K for porous sample. The photoluminescence intensity of the porous film indicated that the optical properties have been enhanced. A high work function metals (Pt and Ni) were deposited as a metal contact on the porous films. The rise and recovery times of the devices were investigated at 390nm chopped light. Finally, the sensitivity and quantum efficiency were also studied.
Abstract: Augmented Reality is an application which combines a live view of real-world environment and computer-generated images. This paper studies and demonstrates an efficient Augmented Reality development in the mobile Android environment with the native Java language and Android SDK. Major components include Barcode Reader, File Loader, Marker Detector, Transform Matrix Generator, and a cloud database.
Abstract: When concrete is exposed to high temperatures, some changes may occur in its physical and mechanical properties. Especially, high strength concrete (HSC), may exhibit damages such as cracks and spallings. To overcome this problem, incorporating polymer fibers such as polypropylene (PP) in concrete is a well-known method. In high temperatures, PP decomposes and releases harmful gases such as CO and CO2. This study researches the use of raw rice husk (RRH) as a sustainable material, instead of PP fibers considering its several favorable properties, and its usability in HSC. RRH and PP fibers were incorporated in concrete at 0.5-3% and 0.2-0.5% by weight of cement, respectively. Concrete specimens were exposed to 20 (control), 300, 600 and 900°C. Under these temperatures, residual compressive and splitting tensile strength was determined. During the high temperature effect, the amount of released harmful gases was measured by a gas detector.
Abstract: Background and objectives: Most of the agricultural products are processed by blanching. Blanching can increase antioxidant activity in white saffron products. The objective of this research were to determine antioxidant activity, to identify, and to measure changes in phenolic substances of fresh and blanched white saffron rhizomes (Curcuma mangga Val.). Methods: White saffron rhizomes were peeled, washed and blanched in boiling water containing 0% or 0.05% citric acid solution for 5 and 10 minutes. Samples were extracted using methanol, rotaevaporated, and freezedried. Dried extract was determined antioxidant activity by DPPH method, identified and quantified for the phenolic substances by High Performance Liquid Chromatography (HPLC) equipped with coloumn C18 and Photodiode-array detector (PAD). Result: This research showed that the quantity of the 6 phenolic substances identified in blanched white saffron in citric acid solution increased significantly compared to that of the non-blanched. Blanching white saffron in 0.05% citric acid media for 5 minutes increased its antioxidant activity, and total phenolic content. Conclusions: The identified phenolic substances of white saffron were Gallic Acid (GA), Catechin (C), Epicatechin (EC), Epigallocatechin (EGC), Epigallocatechingallat (EGCG) and Gallocatechingallat (GCG). The blanched white saffron contained C and EGCG significantly higher than that of fresh rhizomes.
Abstract: Silicon photonics has generated an increasing interest in recent years mainly for optical communications optical interconnects in microelectronic circuits or bio-sensing applications. The development of elementary passive and active components (including detectors and modulators), which are mainly fabricated on the silicon on insulator platform for CMOS-compatible fabrication, has reached such a performance level that the integration challenge of silicon photonics with microelectronic circuits should be addressed. Since crystalline silicon can only be grown from another silicon crystal, making it impossible to deposit in this state, the optical devices are typically limited to a single layer. An alternative approach is to integrate a photonic layer above the CMOS chip using back-end CMOS fabrication process. In this paper, various materials, including silicon nitride, amorphous silicon, and polycrystalline silicon, for this purpose are addressed.
Abstract: An efficient reintegration of the disabled people in the
family and society should be fulfilled; hence it is strongly needful to assist their diminished functions or to replace the totally lost
functions. Assistive technology helps in neutralizing the impairment.
Recent advancements in embedded systems have opened up a vast
area of research and development for affordable and portable assistive devices for the visually impaired. Granted there are many assistive devices on the market that are able to detect obstacles, and numerous research and development currently in process to
alleviate the cause, unfortunately the cost of devices, size of
devices, intrusiveness and higher learning curve prevents the visually impaired from taking advantage of available devices. This
project aims at the design and implementation of a detachable unit
which is robust, low cost and user friendly, thus, trying to
aggrandize the functionality of the existing white cane, to concede above-knee obstacle detection. The designed obstruction detector
uses ultrasound sensors for detecting the obstructions before direct contact. It bestows haptic feedback to the user in accordance with the position of the obstacle.
Abstract: The paper deals with the development of portable aerosol concentrator and its application for the determination of nitrites and nitrates. The device enables the continuous trapping of pollutants in the air. An extensive literature search has been elaborated which aims at the development of samplers and the possibilities of their application in the continuous determination of volatile organic compounds. The practical part of the paper is focused on the development of the portable aerosol concentrator. The device using the Aerosol Enrichment Unit has been experimentally verified and subsequently realized. It operates on the principle of equilibrium accumulation of pollutants from the gaseous phase using absorption liquid polydisperse aerosol. The device has been applied for monitoring nitrites and nitrates in the air. The chemiluminescence detector was used for detection; the achieved detection limit for nitrites was 28 ng/m3 and for nitrates 78 ng/m3.
Abstract: We present a preliminary x-ray study on human-hair
microstructures for a health-state indicator, in particular a cancer
case. As an uncomplicated and low-cost method of x-ray technique,
the human-hair microstructure was analyzed by wide-angle x-ray
diffractions (XRD) and small-angle x-ray scattering (SAXS). The
XRD measurements exhibited the simply reflections at the d-spacing
of 28 Å, 9.4 Å and 4.4 Å representing to the periodic distance of the
protein matrix of the human-hair macrofibrous and the diameter and
the repeated spacing of the polypeptide alpha helixes of the
photofibrils of the human-hair microfibrous, respectively. When
compared to the normal cases, the unhealthy cases including to the
breast- and ovarian-cancer cases obtained higher normalized ratios of
the x-ray diffracting peaks of 9.4 Å and 4.4 Å. This likely resulted
from the varied distributions of microstructures by a molecular
alteration. As an elemental analysis by x-ray fluorescence (XRF), the
normalized quantitative ratios of zinc(Zn)/calcium(Ca) and
iron(Fe)/calcium(Ca) were determined. Analogously, both Zn/Ca and
Fe/Ca ratios of the unhealthy cases were obtained higher than both of
the normal cases were. Combining the structural analysis by XRD
measurements and the elemental analysis by XRF measurements
exhibited that the modified fibrous microstructures of hair samples
were in relation to their altered elemental compositions. Therefore,
these microstructural and elemental analyses of hair samples will be
benefit to associate with a diagnosis of cancer and genetic diseases.
This functional method would lower a risk of such diseases by the
early diagnosis. However, the high-intensity x-ray source, the highresolution
x-ray detector, and more hair samples are necessarily
desired to develop this x-ray technique and the efficiency would be
enhanced by including the skin and fingernail samples with the
human-hair analysis.
Abstract: A new reverse phase-high performance liquid chromatography (RP-HPLC) method with fluorescent detector (FLD) was developed and optimized for Norfloxacin determination in human plasma. Mobile phase specifications, extraction method and excitation and emission wavelengths were varied for optimization. HPLC system contained a reverse phase C18 (5 μm, 4.6 mm×150 mm) column with FLD operated at excitation 330 nm and emission 440 nm. The optimized mobile phase consisted of 14% acetonitrile in buffer solution. The aqueous phase was prepared by mixing 2g of citric acid, 2g sodium acetate and 1 ml of triethylamine in 1 L of Milli-Q water was run at a flow rate of 1.2 mL/min. The standard curve was linear for the range tested (0.156–20 μg/mL) and the coefficient of determination was 0.9978. Aceclofenac sodium was used as internal standard. A detection limit of 0.078 μg/mL was achieved. Run time was set at 10 minutes because retention time of norfloxacin was 0.99 min. which shows the rapidness of this method of analysis. The present assay showed good accuracy, precision and sensitivity for Norfloxacin determination in human plasma with a new internal standard and can be applied pharmacokinetic evaluation of Norfloxacin tablets after oral administration in human.
Abstract: Single photon detectors have been fabricated NbN
nano wire. These detectors are fabricated from high quality, ultra
high vacuum sputtered NbN thin films on a sapphire substrate. In this
work a typical schematic of the nanowire Single Photon Detector
structure and then driving and measurement electronic circuit are
shown.
The response of superconducting nanowire single photon detectors
during a photo detection event, is modeled by a special electrical
circuits (two circuit).
Finally, current through the wire is calculated by solving
equations of models.
Abstract: An image compression method has been developed
using fuzzy edge image utilizing the basic Block Truncation Coding
(BTC) algorithm. The fuzzy edge image has been validated with
classical edge detectors on the basis of the results of the well-known
Canny edge detector prior to applying to the proposed method. The
bit plane generated by the conventional BTC method is replaced with
the fuzzy bit plane generated by the logical OR operation between
the fuzzy edge image and the corresponding conventional BTC bit
plane. The input image is encoded with the block mean and standard
deviation and the fuzzy bit plane. The proposed method has been
tested with test images of 8 bits/pixel and size 512×512 and found to
be superior with better Peak Signal to Noise Ratio (PSNR) when
compared to the conventional BTC, and adaptive bit plane selection
BTC (ABTC) methods. The raggedness and jagged appearance, and
the ringing artifacts at sharp edges are greatly reduced in
reconstructed images by the proposed method with the fuzzy bit
plane.
Abstract: Coherent and incoherent scattering cross section measurements have been carried out using a HPGe detector on elements in the range of Z = 13 - 50 using 241Am gamma rays. The cross sections have been derived by comparing the net count rate obtained from the Compton peak of aluminium with the corresponding peak of the target. The measured cross sections for the coherent and incoherent processes are compared with theoretical values and earlier reported values. Our results are in agreement with the theoretical values.
Abstract: The angular distribution of Compton scattering of two
quanta originating in the annihilation of a positron with an electron
is investigated as a quantum key distribution (QKD) mechanism in
the gamma spectral range. The geometry of coincident Compton
scattering is observed on the two sides as a way to obtain partially
correlated readings on the quantum channel. We derive the noise
probability density function of a conceptually equivalent prepare
and measure quantum channel in order to evaluate the limits of the
concept in terms of the device secrecy capacity and estimate it at
roughly 1.9 bits per 1 000 annihilation events. The high error rate
is well above the tolerable error rates of the common reconciliation
protocols; therefore, the proposed key agreement protocol by public
discussion requires key reconciliation using classical error-correcting
codes. We constructed a prototype device based on the readily
available monolithic detectors in the least complex setup.
Abstract: This article summarizes ways to verify neutron
fluence for neutron transmutation doping of silicon with phosphorus
on the LVR-15 reactor. Neutron fluence is determined using
activation detectors placed along the crystal in a strip or encapsulated
in a rod holder. Holders are placed at the centre of a water-filled
capsule or in an aluminum or silicon ingot that simulates a real single
crystal. If the diameter of the crystal is significantly less than the
capsule diameter and water from the primary circuit enters the free
space in the capsule, neutron interaction in the water changes neutron
fluence, affecting axial irradiation homogeneity. The effect of
moving the capsule vertically in the channel relative to maximum
neutron fluence in the reactor core was also measured. Even a small
shift of the capsule-s centre causes great irradiation inhomogeneity.
This effect was measured using activation detectors, and was also
confirmed by MCNP calculation.
Abstract: Design and implementation of a novel B-ACOSD CFAR algorithm is presented in this paper. It is proposed for detecting radar target in log-normal distribution environment. The BACOSD detector is capable to detect automatically the number interference target in the reference cells and detect the real target by an adaptive threshold. The detector is implemented as a System on Chip on FPGA Altera Stratix II using parallelism and pipelining technique. For a reference window of length 16 cells, the experimental results showed that the processor works properly with a processing speed up to 115.13MHz and processing time0.29 ┬Ás, thus meets real-time requirement for a typical radar system.
Abstract: Ultrafast doped zinc oxide crystal promised us a good
opportunity to build new instruments for ICF fusion neutron
measurement. Two pulsed neutron detectors based on ZnO crystal
wafer have been conceptually designed, the superfast ZnO timing
detector and the scintillation recoil proton neutron detection system.
The structure of these detectors was presented, and some characters
were studied as well. The new detectors could be much faster than
existing systems, and would be more competent for ICF neutron
diagnostics.
Abstract: The construction of original functional sample of the portable device for fast analysis of energetic materials has been described in the paper. The portable device consisting of two parts – an original miniaturized microcolumn liquid chromatograph and a unique chemiluminescence detector – has been proposed and realized. In a very short time, this portable device is capable of identifying selectively most of military nitramine- and nitroesterbased explosives as well as inorganic nitrates occurring in trace concentrations in water or in soil. The total time required for the identification of extracts is shorter than 8 minutes.