Specification of Irradiation Conditions in the DONA 5 Rotational Channel of the LVR-15 Reactor

This article summarizes ways to verify neutron fluence for neutron transmutation doping of silicon with phosphorus on the LVR-15 reactor. Neutron fluence is determined using activation detectors placed along the crystal in a strip or encapsulated in a rod holder. Holders are placed at the centre of a water-filled capsule or in an aluminum or silicon ingot that simulates a real single crystal. If the diameter of the crystal is significantly less than the capsule diameter and water from the primary circuit enters the free space in the capsule, neutron interaction in the water changes neutron fluence, affecting axial irradiation homogeneity. The effect of moving the capsule vertically in the channel relative to maximum neutron fluence in the reactor core was also measured. Even a small shift of the capsule-s centre causes great irradiation inhomogeneity. This effect was measured using activation detectors, and was also confirmed by MCNP calculation.