Abstract: The numerical simulation has made tremendous
advances in investigating the blood flow phenomenon through elastic
arteries. Such study can be useful in demonstrating the disease
progression and hemodynamics of cardiovascular diseases such as
atherosclerosis. In the present study, patient specific case diagnosed
with partially stenosed complete right ICA and normal left carotid
bifurcation without any atherosclerotic plaque formation is
considered. 3D patient specific carotid bifurcation model is generated
based on CT scan data using MIMICS-4.0 and numerical analysis is
performed using FSI solver in ANSYS-14.5. The blood flow is
assumed to be incompressible, homogenous and Newtonian, while
the artery wall is assumed to be linearly elastic. The two-way
sequentially coupled transient FSI analysis is performed using FSI
solver for three pulse cycles. The hemodynamic parameters such as
flow pattern, Wall Shear Stress, pressure contours and arterial wall
deformation are studied at the bifurcation and critical zones such as
stenosis. The variation in flow behavior is studied throughout the
pulse cycle. Also, the simulation results reveal that there is a
considerable increase in the flow behavior in stenosed carotid in
contrast to the normal carotid bifurcation system. The investigation
also demonstrates the disturbed flow pattern especially at the
bifurcation and stenosed zone elevating the hemodynamics,
particularly during peak systole and later part of the pulse cycle. The
results obtained agree well with the clinical observation and
demonstrates the potential of patient specific numerical studies in
prognosis of disease progression and plaque rupture.
Abstract: Cardiovascular disease mostly in the form of atherosclerosis is responsible for 30% of all world deaths amounting to 17 million people per year. Atherosclerosis is due to the formation of plaque. The fatty plaque may be at risk of rupture, leading typically to stroke and heart attack. The plaque is usually associated with a high degree of lumen reduction, called a stenosis. The initiation and progression of the disease is strongly linked to the hemodynamic environment near the vessel wall. The aim of this study is to validate the flow of blood mimic through an arterial stenosis model with computational fluid dynamics (CFD) package. In experiment, an axisymmetric model constructed consists of contraction and expansion region that follow a mathematical form of cosine function. A 30% diameter reduction was used in this study. Particle image velocimetry (PIV) was used to characterize the flow. The fluid consists of rigid spherical particles suspended in waterglycerol- NaCl mixture. The particles with 20 μm diameter were selected to follow the flow of fluid. The flow at Re=155, 270 and 390 were investigated. The experimental result is compared with FLUENT simulated flow that account for viscous laminar flow model. The results suggest that laminar flow model was sufficient to predict flow velocity at the inlet but the velocity at stenosis throat at Re =390 was overestimated. Hence, a transition to turbulent regime might have been developed at throat region as the flow rate increases.