Abstract: Wireless communication technology is rapidly changing with recent developments in portable devices and communication protocols. This has generated demand for more advanced and compact antenna structures and therefore, proposed work focuses on Meander Line Antenna (MLA) design. Here, Pentaband MLA is designed on a FR4 substrate (85 mm x 40 mm) with dielectric constant (ϵr) 4.4, loss tangent (tan ) 0.018 and height 1.6 mm with coplanar feed and open stub structure. It can be operated in LTE (0.670 GHz-0.696 GHz) GPS (1.564 GHz-1.579 GHz), WCDMA (1.920 GHz-2.135 GHz), LTE UL frequency band 23 (2-2.020 GHz) and 5G (3.10 GHz-3.550 GHz) application bands. Also, it gives good performance in terms of Return Loss (RL) which is < -10 dB, impedance bandwidth with maximum Bandwidth (BW) up to 0.21 GHz and realized gains with maximum gain up to 3.28 dBi. Antenna is simulated with open stub and without open stub structures to see the effect on impedance BW coverage. In addition to this, it is checked with human hand and head phantoms to assure that it falls within specified Specific Absorption Rate (SAR) limits.
Abstract: In recent years a new method of combination
treatment for cancer has been developed and studied that has led to
significant advancements in the field of cancer therapy. Hyperthermia
is a traditional therapy that, along with a creation of a medically
approved level of heat with the help of an alternating magnetic AC
current, results in the destruction of cancer cells by heat. This paper
gives details regarding the production of the spherical nanocomposite
PVA/γ-Fe2O3 in order to be used for medical purposes such as tumor
treatment by hyperthermia. To reach a suitable and evenly distributed
temperature, the nanocomposite with core-shell morphology and
spherical form within a 100 to 200 nanometer size was created using
phase separation emulsion, in which the magnetic nano-particles γ-
Fe2O3 with an average particle size of 20 nano-meters and with
different percentages of 0.2, 0.4, 0.5 and 0.6 were covered by
polyvinyl alcohol. The main concern in hyperthermia and heat
treatment is achieving desirable specific absorption rate (SAR) and
one of the most critical factors in SAR is particle size. In this project
all attempts has been done to reach minimal size and consequently
maximum SAR. The morphological analysis of the spherical
structure of the nanocomposite PVA/γ-Fe2O3 was achieved by SEM
analyses and the study of the chemical bonds created was made
possible by FTIR analysis. To investigate the manner of magnetic
nanocomposite particle size distribution a DLS experiment was
conducted. Moreover, to determine the magnetic behavior of the γ-
Fe2O3 particle and the nanocomposite PVA/γ-Fe2O3 in different
concentrations a VSM test was conducted. To sum up, creating
magnetic nanocomposites with a spherical morphology that would be
employed for drug loading opens doors to new approaches in
developing nanocomposites that provide efficient heat and a
controlled release of drug simultaneously inside the magnetic field,
which are among their positive characteristics that could significantly
improve the recovery process in patients.
Abstract: This paper presents breast cancer detection by
observing the specific absorption rate (SAR) intensity for
identification tumor location, the tumor is identified in coordinates
(x,y,z) system. We examined the frequency between 4-8 GHz to look
for the most appropriate frequency. Results are simulated in
frequency 4-8 GHz, the model overview include normal breast with
50 mm radian, 5 mm diameter of tumor, and ultra wideband (UWB)
bowtie antenna. The models are created and simulated in CST
Microwave Studio. For this simulation, we changed antenna to 5
location around the breast, the tumor can be detected when an
antenna is close to the tumor location, which the coordinate of
maximum SAR is approximated the tumor location. For reliable, we
experiment by random tumor location to 3 position in the same size
of tumor and simulation the result again by varying the antenna
position in 5 position again, and it also detectable the tumor position
from the antenna that nearby tumor position by maximum value of
SAR, which it can be detected the tumor with precision in all
frequency between 4-8 GHz.
Abstract: A low profile planar antenna for twelve-band operation in the mobile phone is presented. The proposed antenna radiating elements occupy an area equals 17 × 50 mm2 are mounted on the compact no-ground portion of the system circuit board to achieve a simple low profile structure. In order to overcome the shortcoming of narrow bandwidth for conventional planar printed antenna, a novel bandwidth enhancement approach for multiband handset antennas is proposed here. The technique used in this study shows that by using a coupled-fed mechanism and a slotted ground structure, a multiband operation with wideband characteristic can be achieved. The influences of the modifications introduced into the ground plane improved significantly the bandwidths of the designed antenna. The slotted ground plane structure with the coupled-fed elements contributes their lowest, middle and higher-order resonant modes to form four operating modes. The generated modes are able to cover LTE 700/2300/2500, GSM 850/900/1800/1900, UMTS, WiMAX 3500, WLAN 2400/5200/5800 operations. Parametric studies via simulation are provided and discussed. Proposed antenna’s gain, efficiency and radiation pattern characteristics over the desired operating bands are obtained and discussed. The reasonable results observed can meet the requirements of practical mobile phones.
Abstract: This paper investigates the impact of the hand-hold
positions on both antenna performance and the specific absorption
rate (SAR) induced in the user-s head. A cellular handset with
external antenna operating at GSM-900 frequency is modeled and
simulated using a finite difference time-domain (FDTD)-based
platform SEMCAD-X. A specific anthropomorphic mannequin
(SAM) is adopted to simulate the user-s head, whereas a semirealistic
CAD-model of three-tissues is designed to simulate the
user-s hand. The results show that in case of the handset in hand close
to head at different positions; the antenna total efficiency gets
reduced to (14.5% - 5.9%) at cheek-position and to (27.5% to 11.8%)
at tilt-position. The peak averaged SAR1g values in head close to
handset without hand, are 4.67 W/Kg and 2.66 W/Kg at cheek and
tilt-position, respectively. Due to the presence of hand, the SAR1g in
head gets reduced to (3.67-3.31 W/Kg) at cheek-position and to
(1.84-1.64 W/Kg) at tilt-position, depending on the hand-hold
position.
Abstract: This paper discusses the investigation of a wearable
textile monopole antenna on specific absorption rate (SAR) for bodycentric
wireless communication applications at 2.45 GHz. The
antenna is characterized on a realistic 8 x 8 x 8 mm3 resolution
truncated Hugo body model in CST Microwave Studio software. The
result exhibited that the simulated SAR values were reduced
significantly by 83.5% as the position of textile monopole was
varying between 0 mm and 15 mm away from the human upper arm.
A power absorption reduction of 52.2% was also noticed as the
distance of textile monopole increased.