Abstract: In the paper introduced the diagnostic technique making possible the research of internal structures in composite materials reinforced fibres using in different applications. The main reason of damages in structures of these materials is the changing distribution of load in constructions in the lifetime. Appearing defect is largely complicated because of the appearance of disturbing of continuity of reinforced fibres, binder cracks and loss of fibres adhesiveness from binders. Defect in composite materials is usually more complicated than in metals. At present, infrared thermography is the most effective method in non-destructive testing composite. One of IR thermography methods used in non-destructive evaluation is vibrothermography. The vibrothermography is not a new non-destructive method, but the new solution in this test is use ultrasonic waves to thermal stimulation of materials. In this paper, both modelling and experimental results which illustrate the advantages and limitations of ultrasonic IR thermography in inspecting composite materials will be presented. The ThermoSon computer program for computing 3D dynamic temperature distribuions in anisotropic layered solids with subsurface defects subject to ulrasonic stimulation was used to optimise heating parameters in the detection of subsurface defects in composite materials. The program allows for the analysis of transient heat conduction and ultrasonic wave propagation phenomena in solids. The experiments at MIAT were fulfilled by means of FLIR SC 7600 IR camera. Ultrasonic stimulation was performed with the frequency from 15 kHz to 30 kHz with maximum power up to 2 kW.
Abstract: The X-ray technology has been used in non-destructive evaluation in the Power System, in which a visual non-destructive inspection method for the electrical equipment is provided. However, lots of noise is existed in the images that are got from the X-ray digital images equipment. Therefore, the auto defect detection which based on these images will be very difficult to proceed. A theory on X-ray image de-noising algorithm based on wavelet transform is proposed in this paper. Then the edge detection algorithm is used so that the defect can be pushed out. The result of experiment shows that the method which utilized by this paper is very useful for de-noising on the X-ray images.
Abstract: Science and technology of ultrasonic is widely used in
recent years for industrial and medicinal application. The acoustical
properties of 2-mercapto substituted pyrimidines viz.,2- Mercapto-4-
(2’,4’ –dichloro phenyl) – 6-(2’ – hydroxyl -4’ –methyl-5’ –
chlorophenyl) pyrimidine and 2 –Mercapto – 4-(4’ –chloro phenyl) –
6-(2’ – hydroxyl -4’ –methyl-5’ –chlorophenyl) pyrimidine have been
investigated from the ultrasonic velocity and density measurements at
different concentration and different % in dioxane-water mixture at
305K. The adiabatic compressibility (βs), acoustic impedance (Z),
intermolecular free length (Lf), apparent molar volume(ϕv) and
relative association (RA) values have been calculated from the
experimental data of velocity and density measurement at
concentration range of 0.01- 0.000625 mol/lit and 70%,75% and 80%
dioxane water mixture. These above parameters are used to discuss
the structural and molecular interactions.
Abstract: Significant changes in oil and gas drilling have
emphasized the need to verify the integrity and reliability of drill
stem components. Defects are inevitable in cast components,
regardless of application; but if these defects go undetected, any
severe defect could cause down-hole failure.
One such defect is shrinkage porosity. Castings with lower level
shrinkage porosity (CB levels 1 and 2) have scattered pores and do
not occupy large volumes; so pressure testing and helium leak testing
(HLT) are sufficient for qualifying the castings. However, castings
with shrinkage porosity of CB level 3 and higher, behave erratically
under pressure testing and HLT making these techniques insufficient
for evaluating the castings- integrity.
This paper presents a case study to highlight how the radiography
technique is much more effective than pressure testing and HLT.
Abstract: Non-Destructive evaluation of in-service power
transformer condition is necessary for avoiding catastrophic failures.
Dissolved Gas Analysis (DGA) is one of the important methods.
Traditional, statistical and intelligent DGA approaches have been
adopted for accurate classification of incipient fault sources.
Unfortunately, there are not often enough faulty patterns required for
sufficient training of intelligent systems. By bootstrapping the
shortcoming is expected to be alleviated and algorithms with better
classification success rates to be obtained. In this paper the
performance of an artificial neural network, K-Nearest Neighbour
and support vector machine methods using bootstrapped data are
detailed and shown that while the success rate of the ANN algorithms
improves remarkably, the outcome of the others do not benefit so
much from the provided enlarged data space. For assessment, two
databases are employed: IEC TC10 and a dataset collected from
reported data in papers. High average test success rate well exhibits
the remarkable outcome.
Abstract: The non-destructive testing of launch tube weld with
radiography was investigated and evaluated with AWS D1.1
standard. The paper started with preparation of launch tube and
radiographic inspection. X-Ray inspection then was done and gotten
the result. The judgment of inspection results were concluded by
certified person and finally, the evaluation with AWS D1.1 standard
was conducted as well.
The result shown that weld position P1 was not conformed to
AWS D1.1 which allowed size of incomplete penetration did not
exceed 4 mm. The other welds were corresponded to as mentioned
standard. Additionally, the corrective actions for incomplete
penetration either provided for future actions.