Abstract: In this paper, seismic fragility assessment of a recently developed hybrid structural system, known as the strongback system (SBS) is investigated. In this system, to mitigate the occurrence of the soft-story mechanism and improve the distribution of story drifts over the height of the structure, an elastic vertical truss is formed. The strengthened members of the braced span are designed to remain substantially elastic during levels of excitation where soft-story mechanisms are likely to occur and impose a nearly uniform story drift distribution. Due to the distinctive characteristics of near-field ground motions, it seems to be necessary to study the effect of these records on seismic performance of the SBS. To this end, a set of 56 near-field ground motion records suggested by FEMA P695 methodology is used. For fragility assessment, nonlinear dynamic analyses are carried out in OpenSEES based on the recommended procedure in HAZUS technical manual. Four damage states including slight, moderate, extensive, and complete damage (collapse) are considered. To evaluate each damage state, inter-story drift ratio and floor acceleration are implemented as engineering demand parameters. Further, to extend the evaluation of the collapse state of the system, a different collapse criterion suggested in FEMA P695 is applied. It is concluded that SBS can significantly increase the collapse capacity and consequently decrease the collapse risk of the structure during its life time. Comparing the observing mean annual frequency (MAF) of exceedance of each damage state against the allowable values presented in performance-based design methods, it is found that using the elastic vertical truss, improves the structural response effectively.
Abstract: Recent ground motion records demonstrate that the near-field earthquakes have various properties compared to far-field earthquakes. In general, most of these properties are affected by an important phenomenon called ‘forward directivity’ in near-fault earthquakes. Measuring structural damages are one of the common activities administered after an earthquake. Predicting the amount of damage caused by the earthquake as well as determining the vulnerability of the structure is extremely significant. In order to measure the amount of structural damages, instead of calculating the acceleration and velocity spectrum, it is possible to use the damage spectra of the structure. The damage spectrum is a kind of nonlinear spectrum that is drawn by setting the nonlinear parameters related to the single degree of freedom structures and its dynamic analysis under the specific record and measuring damage of any structure. In this study, the damage spectra of steel structures have been drawn. For this purpose, different kinds of concentric and eccentric braced structures with various ductility coefficients in hard and soft soil under near-field and far-field ground motion records have been considered using the Krawinkler and Zohrei damage index. The results indicate that, by increasing the structures' fundamental period, the amount of damage increases under the near-field earthquakes compared to far-field earthquakes. In addition, by increasing the structure ductility, the amount of damage based on near-field and far-field earthquakes decreases noticeably. Furthermore, in concentric braced structures, the amount of damage under the near-field earthquakes is almost two times more than the amount of damage in eccentrically braced structures especially for fundamental periods larger than 0.6 s.
Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: The paper presents a plastic analysis procedure based
on the energy balance concept for performance based seismic retrofit
of multi-story multi-bay masonry infilled reinforced concrete (R/C)
frames with a ‘soft’ ground story using passive energy dissipation
(PED) devices with the objective of achieving a target performance
level of the retrofitted R/C frame for a given seismic hazard level at
the building site. The proposed energy based plastic analysis
procedure was employed for developing performance based design
(PBD) formulations for PED devices for a simulated application in
seismic retrofit of existing frame structures designed in compliance
with the prevalent standard codes of practice. The PBD formulations
developed for PED devices were implemented for simulated seismic
retrofit of a representative code-compliant masonry infilled R/C
frame with a ‘soft’ ground story using friction dampers as the PED
device. Non-linear dynamic analyses of the retrofitted masonry
infilled R/C frames is performed to investigate the efficacy and
accuracy of the proposed energy based plastic analysis procedure in
achieving the target performance level under design level
earthquakes. Results of non-linear dynamic analyses demonstrate that
the maximum inter-story drifts in the masonry infilled R/C frames
with a ‘soft’ ground story that is retrofitted with the friction dampers
designed using the proposed PBD formulations are controlled within
the target drifts under near-field as well far-field earthquakes.
Abstract: Performance based design (PBD) is an iterative exercise in which a preliminary trial design of the building structure is selected and if the selected trial design of the building structure does not conform to the desired performance objective, the trial design is revised. In this context, development of a fundamental approach for performance based seismic design of masonry infilled frames with minimum number of trials is an important objective. The paper presents a plastic design procedure based on the energy balance concept for PBD of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames subjected to near-field earthquakes. The proposed energy based plastic design procedure was implemented for trial performance based seismic design of representative masonry infilled reinforced concrete frames with various practically relevant distributions of masonry infill panels over the frame elevation. Non-linear dynamic analyses of the trial PBD of masonry infilled R/C frames was performed under the action of near-field earthquake ground motions. The results of non-linear dynamic analyses demonstrate that the proposed energy method is effective for performance based design of masonry infilled R/C frames under near-field as well as far-field earthquakes.