Abstract: This paper presents the design process of a high
performance 3-phase 3.7 kW 2-pole line start permanent magnet
synchronous motor for pumping system. A method was proposed to
study the starting torque characteristics considering line start with
high inertia load. A d-q model including cage was built to study the
synchronization capability. Time-stepping finite element method
analysis was utilized to accurately predict the dynamic and transient
performance, efficiency, starting current, speed curve and etc.
Considering the load torque of pumps during starting stage, the rotor
bar was designed with minimum demagnetization of permanent
magnet caused by huge starting current.
Abstract: The line start permanent magnet motor (LSPMM)
combines a permanent magnet rotor for a better motor efficiency
during synchronous running with an induction motor squirrel cage
rotor to permit the motor starting by direct coupling to power source.
In this paper effect of the rotor structure on a line start synchronous
permanent magnet motor (LSPMM) is analyzed. LSPMM motor with
three different structures for rotor is designed by using RMxprt
software; efficiency and line current of LSPMM motor for different
structures in full-load condition have been presented. The results
indicate that with correct choosing of rotor structure, maximum
efficiency can be found.