Abstract: This paper presents the design process of a high
performance 3-phase 3.7 kW 2-pole line start permanent magnet
synchronous motor for pumping system. A method was proposed to
study the starting torque characteristics considering line start with
high inertia load. A d-q model including cage was built to study the
synchronization capability. Time-stepping finite element method
analysis was utilized to accurately predict the dynamic and transient
performance, efficiency, starting current, speed curve and etc.
Considering the load torque of pumps during starting stage, the rotor
bar was designed with minimum demagnetization of permanent
magnet caused by huge starting current.