Starting Characteristic Analysis of LSPM for Pumping System Considering Demagnetization

This paper presents the design process of a high performance 3-phase 3.7 kW 2-pole line start permanent magnet synchronous motor for pumping system. A method was proposed to study the starting torque characteristics considering line start with high inertia load. A d-q model including cage was built to study the synchronization capability. Time-stepping finite element method analysis was utilized to accurately predict the dynamic and transient performance, efficiency, starting current, speed curve and etc. Considering the load torque of pumps during starting stage, the rotor bar was designed with minimum demagnetization of permanent magnet caused by huge starting current.




References:
[1] M.A Rahman and T.M. Osheiba, "Performance of a large line start
permanent magnet synchronous motor", IEEE Trans. Energy
Conversion, vol. 5, pp.211-217, Mar.1990.
[2] T.J.E. Miller, "Synchronization of line-start permanent magnet AC
motor", IEEE Trans. Industry Application, vol.PAS-103, Juillet 1984, pp
1822-1828.
[3] Li Gies, GuoZhongbao, Wang Chunyuan, Giu Hong, GuoDaling, "High
Starting Torque and High Efficiency REPM Synchronous Motor",
Proceeding of the Seventh International Workshop on Rare Earth-Cobalt
Permanent Magnets and Their Applications, Beijing, China, Sept. 1983,
Chana Academic Publishers, pp.13-20.
[4] A. Takahashi, S. Kikuchi, K. Miyata, S. Wakui, H. Mikami, and A.
Binder, “Transient-torque analysis for line-starting permanent-magnet
synchronous motors”, Proceeding of the 2008 International Conferences
on Electrical Machines, Beijing, China, Sept. 1983, Chana Academic
Publishers, pp.13-20.
[5] G.H. Kang, J. Hur, H. Nam, J.P. Hong and G.T. Kim “Analysis of
irreversible magnet demagnetization in line-start motors based on the
finite-element method”, IEEE Trans. On Magn., vol.39, no.3,
pp.1488~1491, May, 2003.
[6] W.H Kim, K.C Kim “A study on the optimal rotor design of LSPM
considering the starting torque and efficiency”, IEEE Trans. on magn.,
Vol.45,No.3, March 2009
[7] Tingting Ding , Takorabet N.,Sargos F-M, Xiuhe Wang, “ Design and
Analysis of different line start PM synchronous motor for oil-pump
applications”, IEEE Trans. on magn.,Vol.45, No.3, March 2009
[8] T. J. E. Miller, “Synchronization of line-start permanent magnet AC
motors,” IEEE Trans. Power App. Syst., vol. PAS-103, no. 7, pp. 1822–
1828, Jul 1984.
[9] J. Soulard and H. P. Nee, “Study of the synchronization of line-start
permanent magnet synchronous motors,” in Proc. IEEE Ind. Applicat.
Soc. Annu. Meeting, Roma, Italy, 2000, pp. 424–431. [10] V. B. Honsinger, “Permanent magnet machines: Asynchronous
operation,” IEEE Trans. Power App. Syst., vol. PAS-99, no. 7, pp.
1503–1509, Jul. 1980.