Abstract: This research aims to study the species, feeding behavior and activity characteristics of birds which reap benefits from the research area in boat touring routes in Klong Kone Sub-district, Muang District, Samut Songkram Province, Thailand from October 2013 – May 2014. The results from the survey of birds on all three routes found that there are 11 families and 22 species. Route 1 (Klong Kone canal) had the most species, 20 species. According to feeding behavior, there were insectivorous, piscivorous and aquatic invertebrate feeder birds. Activity characteristics of birds which reap benefits from the research were finding food, nesting and raise nestlings along boat touring routes.
Abstract: This research aims to study species, abundance, status
of birds, the similarities and activity characteristics of birds which
reap benefits from the research area in boat touring routes in Tha Ka
sub-district, Amphawa District, Samut Songkram Province, Thailand.
from October 2012 – September 2013. The data was analyzed to find
the abundance, and similarity index of the birds. The results from the
survey of birds on all three routes found that there are 33 families and
63 species. Route 3 (traditional coconut sugar making kiln – resort)
had the most species; 56 species. There were 18 species of commonly
found birds with an abundance level of 5, which calculates to 28.57%
of all bird species. In August, 46 species are found, being the greatest
number of bird species benefiting from this route. As for the status of
the birds, there are 51 resident birds, 7 resident and migratory birds,
and 5 migratory birds. On Route 2 and Route 3, the similarity index
value is equal to 0.881. The birds are classified by their activity
characteristics i.e. insectivore, piscivore, granivore, nectrivore and
aquatic invertebrate feeder birds. Some birds also use the area for
nesting.
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. The distribution feeder reconfiguration (DFR) is one of the most important control schemes in the distribution networks, which can be affected by DGs. This paper presents a new approach to DFR at the distribution networks considering wind turbines. The main objective of the DFR is to minimize the deviation of the bus voltage. Since the DFR is a nonlinear optimization problem, we apply the Adaptive Modified Firefly Optimization (AMFO) approach to solve it. As a result of the conflicting behavior of the single- objective function, a fuzzy based clustering technique is employed to reach the set of optimal solutions called Pareto solutions. The approach is tested on the IEEE 32-bus standard test system.
Abstract: Power distribution systems typically have tie and sectionalizing switches whose states determine the topological configuration of the network. The aim of network reconfiguration of the distribution network is to minimize the losses for a load arrangement at a particular time. Thus the objective function is to minimize the losses of the network by satisfying the distribution network constraints. The various constraints are radiality, voltage limits and the power balance condition. In this paper the status of the switches is obtained by using Artificial Bee Colony (ABC) algorithm. ABC is based on a particular intelligent behavior of honeybee swarms. ABC is developed based on inspecting the behaviors of real bees to find nectar and sharing the information of food sources to the bees in the hive. The proposed methodology has three stages. In stage one ABC is used to find the tie switches, in stage two the identified tie switches are checked for radiality constraint and if the radilaity constraint is satisfied then the procedure is proceeded to stage three otherwise the process is repeated. In stage three load flow analysis is performed. The process is repeated till the losses are minimized. The ABC is implemented to find the power flow path and the Forward Sweeper algorithm is used to calculate the power flow parameters. The proposed methodology is applied for a 33–bus single feeder distribution network using MATLAB.
Abstract: In this paper, a design of ultra wideband (UWB) printed microstrip antennas that fed by microstrip transmission line were presented and printed on a substrate Taconic TLY-5 material with relative dielectric constant of 2.2. The proposed antennas were designed to cover the frequency range of 3.5 to 12 GHz. The antennas of printed patch shapes are rectangular, triangle/rectangular, hexagonal, and circular with the same dimensions of feeder and ground plane. The proposed antennas were simulated using a package of CST microwave studio in the 2 to 12 GHz operating frequency range. Simulation results and comparison for return loss (S11), radiation patterns, and voltage standing wave ratio (VSWR) were presented and discussed over the UWB frequency.
Abstract: The problem of optimal planning of multiple sources
of distributed generation (DG) in distribution networks is treated in
this paper using an improved Ant Colony Optimization algorithm
(ACO). This objective of this problem is to determine the DG
optimal size and location that in order to minimize the network real
power losses. Considering the multiple sources of DG, both size and
location are simultaneously optimized in a single run of the proposed
ACO algorithm. The various practical constraints of the problem are
taken into consideration by the problem formulation and the
algorithm implementation. A radial power flow algorithm for
distribution networks is adopted and applied to satisfy these
constraints. To validate the proposed technique and demonstrate its
effectiveness, the well-know 69-bus feeder standard test system is
employed.cm.
Abstract: This paper presents an efficient approach to feeder
reconfiguration for power loss reduction and voltage profile
imprvement in unbalanced radial distribution systems (URDS). In
this paper Genetic Algorithm (GA) is used to obtain solution for
reconfiguration of radial distribution systems to minimize the losses.
A forward and backward algorithm is used to calculate load flows in
unbalanced distribution systems. By simulating the survival of the
fittest among the strings, the optimum string is searched by
randomized information exchange between strings by performing
crossover and mutation. Results have shown that proposed algorithm
has advantages over previous algorithms The proposed method is
effectively tested on 19 node and 25 node unbalanced radial
distribution systems.
Abstract: In Algeria, now, the oil pumping plants are fed with electric power by independent local sources. This type of feeding has many advantages (little climatic influence, independent operation). However it requires a qualified maintenance staff, a rather high frequency of maintenance and repair and additional fuel costs. Taking into account the increasing development of the national electric supply network (Sonelgaz), a real possibility of transfer of the local sources towards centralized sources appears.These latter cannot only be more economic but more reliable than the independent local sources as well. In order to carry out this transfer, it is necessary to work out an optimal strategy to rebuilding these networks taking in account the economic parameters and the indices of reliability.
Abstract: Continuous pyrolysis of Cogongrass by control
temperature in the novel pyrolysis reactor were conducted at three
difference temperatures 400, 450 and 500°C. Preliminary calculate of
the product yields founded the liquid yield of Cogongrass was
highest of 41.45 %, at 500 oC. Indicated that the liquid yield from
Cogongrass had good received yields because it gave over 40 % and
its produced more liquid than that solid and gas. The compounds
detected in bio-oil from Cogongrass showed the functional group,
especially; Phenol, Phenol, 2,5-dimethyl, Phenol, 3-methyl, 2-
methyl-1,3-oxathiofane, Benzene,1-ethyl-4-methoxy, 2-Cyclopenten-
1-one,2,3-dimethyl, 2- Cyclopenten-1- one, 3-Methyl.
Abstract: This paper presents the influence of distributed generation (DG) on congestion and locational marginal price (LMP) in an optimal power flow (OPF) based wholesale electricity market. The problem of optimal placement to manage congestion and reduce LMP is formulated for the objective of social welfare maximization. From competitive electricity market standpoint, DGs have great value when they reduce load in particular locations and at particular times when feeders are heavily loaded. The paper lies on the groundwork that solution to optimal mix of generation and transmission resources can be achieved by addressing congestion and corresponding LMP. Obtained as lagrangian multiplier associated with active power flow equation for each node, LMP gives the short run marginal cost (SRMC) of electricity. Specific grid locations are examined to study the influence of DG penetration on congestion and corresponding shadow prices. The influence of DG on congestion and locational marginal prices has been demonstrated in a modified IEEE 14 bus test system.
Abstract: An electric power system includes a generating, a
transmission, a distribution, and consumers subsystems. An electrical
power network in Tanzania keeps growing larger by the day and
become more complex so that, most utilities have long wished for
real-time monitoring and remote control of electrical power system
elements such as substations, intelligent devices, power lines,
capacitor banks, feeder switches, fault analyzers and other physical
facilities. In this paper, the concept of automation of management of
power systems from generation level to end user levels was
determined by using Power System Simulator for Engineering
(PSS/E) version 30.3.2.
Abstract: A multiphase harmonic load flow algorithm is developed based on backward/forward sweep to examine the effects of various factors on the neutral to earth voltage (NEV), including unsymmetrical system configuration, load unbalance and harmonic injection. The proposed algorithm composes fundamental frequency and harmonic frequencies power flows. The algorithm and the associated models are tested on IEEE 13 bus system. The magnitude of NEV is investigated under various conditions of the number of grounding rods per feeder lengths, the grounding rods resistance and the grounding resistance of the in feeding source. Additionally, the harmonic injection of nonlinear loads has been considered and its influences on NEV under different conditions are shown.
Abstract: DG application has received increasing attention during
recent years. The impact of DG on various aspects of distribution system
operation, such as reliability and energy loss, depend highly on DG
location in distribution feeder. Optimal DG placement is an important
subject which has not been fully discussed yet.
This paper presents an optimization method to determine optimal DG
placement, based on a cost/worth analysis approach. This method
considers technical and economical factors such as energy loss, load point
reliability indices and DG costs, and particularly, portability of DG. The
proposed method is applied to a test system and the impacts of different
parameters such as load growth rate and load forecast uncertainty (LFU)
on optimum DG location are studied.
Abstract: Modern highly automated production systems faces
problems of reliability. Machine function reliability results in
changes of productivity rate and efficiency use of expensive
industrial facilities. Predicting of reliability has become an important
research and involves complex mathematical methods and
calculation. The reliability of high productivity technological
automatic machines that consists of complex mechanical, electrical
and electronic components is important. The failure of these units
results in major economic losses of production systems. The
reliability of transport and feeding systems for automatic
technological machines is also important, because failure of transport
leads to stops of technological machines. This paper presents
reliability engineering on the feeding system and its components for
transporting a complex shape parts to automatic machines. It also
discusses about the calculation of the reliability parameters of the
feeding unit by applying the probability theory. Equations produced
for calculating the limits of the geometrical sizes of feeders and the
probability of sticking the transported parts into the chute represents
the reliability of feeders as a function of its geometrical parameters.
Abstract: Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.
Abstract: This paper presents an efficient algorithm for
optimization of radial distribution systems by a network
reconfiguration to balance feeder loads and eliminate overload
conditions. The system load-balancing index is used to determine the
loading conditions of the system and maximum system loading
capacity. The index value has to be minimum in the optimal network
reconfiguration of load balancing. A method based on Tabu search
algorithm, The Tabu search algorithm is employed to search for the
optimal network reconfiguration. The basic idea behind the search is
a move from a current solution to its neighborhood by effectively
utilizing a memory to provide an efficient search for optimality. It
presents low computational effort and is able to find good quality
configurations. Simulation results for a radial 69-bus system with
distributed generations and capacitors placement. The study results
show that the optimal on/off patterns of the switches can be identified
to give the best network reconfiguration involving balancing of
feeder loads while respecting all the constraints.
Abstract: The great majority of the electric installations belong
to the first and second category. In order to ensure a high level of
reliability of their electric system feeder, two power supply sources
are envisaged, one principal, the other of reserve, generally a cold
reserve (electric diesel group).
The principal source being under operation, its control can be ideal
and sure, however for the reserve source being in stop, a preventive
maintenance-s which proceeds on time intervals (periodicity) and
for well defined lengths of time are envisaged, so that this source will
always available in case of the principal source failure.
The choice of the periodicity of preventive maintenance of the
source of reserve influences directly the reliability of the electric
feeder system. On the basis of the semi-markovians processes, the
influence of the periodicity of the preventive maintenance of the
source of reserve is studied and is given the optimal periodicity.
Abstract: This paper reports a new and accurate method for load-flow solution of radial distribution networks with minimum data preparation. The node and branch numbering need not to be sequential like other available methods. The proposed method does not need sending-node, receiving-node and branch numbers if these are sequential. The proposed method uses the simple equation to compute the voltage magnitude and has the capability to handle composite load modelling. The proposed method uses the set of nodes of feeder, lateral(s) and sub lateral(s). The effectiveness of the proposed method is compared with other methods using two examples. The detailed load-flow results for different kind of load-modellings are also presented.
Abstract: The demand on High voltage (HV) infrastructures is growing due to the corresponding growth in industries and population. New or upgraded HV infrastructure has safety implications since Transmission mains usually occupy the same easement in the vicinity of neighbouring residents. Transmission mains consist of underground (UG) and overhead (OH) sections and the transition between the UG and OH section is known as the UGOH pole. The existence of two transmission mains in the same easement can dictate to resort to more complicated earthing design in order to mitigate the effect of AC interference, and in some cases it can also necessitates completing a Split Study of the system. This paper provides an overview of the AC interference, Split Study and the earthing of an underground feeder including the UGOH pole .In addition, this paper discusses the use of different link boxes on the UG feeder and presents a case study that represent a clear example of the Ac interference and Split factor. Finally, a few recommendations are provided to achieve a safety zone in the area beyond the boundary of the HV system.
Abstract: An optical fault monitoring in FTTH-PON using ACS
is demonstrated. This device can achieve real-time fault monitoring
for protection feeder fiber. In addition, the ACS can distinguish
optical fiber fault from the transmission services to other customers
in the FTTH-PON. It is essential to use a wavelength different from
the triple-play services operating wavelengths for failure detection.
ACS is using the operating wavelength 1625 nm for monitoring and
failure detection control. Our solution works on a standard local area
network (LAN) using a specially designed hardware interfaced with a
microcontroller integrated Ethernet.