Abstract: The The dynamic economic dispatch (DED) problem is one of the complex constrained optimization problems that have nonlinear, con-convex and non-smooth objective functions. The purpose of the DED is to determine the optimal economic operation of the committed units while meeting the load demand. Associated to this constrained problem there exist highly nonlinear and non-convex practical constraints to be satisfied. Therefore, classical and derivative-based methods are likely not to converge to an optimal or near optimal solution to such a dynamic and large-scale problem. In this paper, an Artificial Immune System technique (AIS) is implemented and applied to solve the DED problem considering the transmission power losses and the valve-point effects in addition to the other operational constraints. To demonstrate the effectiveness of the proposed technique, two case studies are considered. The results obtained using the AIS are compared to those obtained by other methods reported in the literature and found better.
Abstract: The dynamic economic dispatch (DED) problem is one of the complex constrained optimization problems that have nonlinear, con-convex and non-smooth objective functions. The purpose of the DED is to determine the optimal economic operation of the committed units while meeting the load demand. Associated to this constrained problem there exist highly nonlinear and non-convex practical constraints to be satisfied. Therefore, classical and derivative-based methods are likely not to converge to an optimal or near optimal solution to such a dynamic and large-scale problem. In this paper, an Artificial Immune System technique (AIS) is implemented and applied to solve the DED problem considering the transmission power losses and the valve-point effects in addition to the other operational constraints. To demonstrate the effectiveness of the proposed technique, two case studies are considered. The results obtained using the AIS are compared to those obtained by other methods reported in the literature and found better.
Abstract: The problem of optimal planning of multiple sources
of distributed generation (DG) in distribution networks is treated in
this paper using an improved Ant Colony Optimization algorithm
(ACO). This objective of this problem is to determine the DG
optimal size and location that in order to minimize the network real
power losses. Considering the multiple sources of DG, both size and
location are simultaneously optimized in a single run of the proposed
ACO algorithm. The various practical constraints of the problem are
taken into consideration by the problem formulation and the
algorithm implementation. A radial power flow algorithm for
distribution networks is adopted and applied to satisfy these
constraints. To validate the proposed technique and demonstrate its
effectiveness, the well-know 69-bus feeder standard test system is
employed.cm.