Abstract: Nowadays use of a new structural bracing system
called 'Knee Bracing System' have taken the specialists attention too
much. On the other hand nonlinear static analysis procedures in
estimate structures performance in earthquake time have taken
attention too much. One of these procedure is modal pushover
analysis (MPA) procedure. The accuracy of MPA procedure for
simple steel moment resisting frame has been verified and considered
in Chintanapakdee and Chopra-s article in 2003. Since the accuracy
of MPA procedure has not verified for semi-rigid steel frames with
knee bracing, we are going to get through with this matter in this
study. For this purpose, the selected structures are four frames with
different heights, 5 to 20 stories, will be designed according to AISC
criteria. Then MPA procedure is used for the same frames with
different rigidity percentiles of connections. The results of seismic
responses are compared with dynamic nonlinear response history
analysis as exact procedure and accuracy of MPA procedure is
evaluated. It seems that MPA procedure accuracy will come down by
reduction of the rigidity percentiles of semi-rigid connections.
Abstract: Since the actuator capacity is limited, in the real
application of active control systems under sever earthquakes it is
conceivable that the actuators saturate, hence the actuator saturation
should be considered as a constraint in design of optimal controllers.
In this paper optimal design of active controllers for nonlinear
structures by considering actuator saturation, has been studied. The
proposed method for designing optimal controllers is based on
defining an optimization problem which the objective has been to
minimize the maximum displacement of structure when a limited
capacity for actuator has been used. To this end a single degree of
freedom (SDF) structure with a bilinear hysteretic behavior has been
simulated under a white noise ground acceleration of different
amplitudes. Active tendon control mechanism, comprised of prestressed
tendons and an actuator, and extended nonlinear Newmark
method based instantaneous optimal control algorithm have been
used. To achieve the best results, the weights corresponding to
displacement, velocity, acceleration and control force in the
performance index have been optimized by the Distributed Genetic
Algorithm (DGA). Results show the effectiveness of the proposed
method in considering actuator saturation. Also based on the
numerical simulations it can be concluded that the actuator capacity
and the average value of required control force are two important
factors in designing nonlinear controllers which consider the actuator
saturation.
Abstract: Recent trends in building constructions in Libya are
more toward tall (high-rise) building projects. As a consequence, a
better estimation of the lateral loading in the design process is
becoming the focal of a safe and cost effective building industry. Byin-
large, Libya is not considered a potential earthquake prone zone,
making wind is the dominant design lateral loads. Current design
practice in the country estimates wind speeds on a mere random
bases by considering certain factor of safety to the chosen wind
speed. Therefore, a need for a more accurate estimation of wind
speeds in Libya was the motivation behind this study. Records of
wind speed data were collected from 22 metrological stations in
Libya, and were statistically analysed. The analysis of more than four
decades of wind speed records suggests that the country can be
divided into four zones of distinct wind speeds. A computer “survey"
program was manipulated to draw design wind speeds contour map
for the state of Libya.
The paper presents the statistical analysis of Libya-s recorded
wind speed data and proposes design wind speed values for a 50-year
return period that covers the entire country.
Abstract: This paper presents an analytical solution to get a reliable estimation of the hydrodynamic pressure on gravity dams induced by vertical component earthquake when solving the fluid and dam interaction problem. Presented analytical technique is presented for calculation of earthquake-induced hydrodynamic pressure in the reservoir of gravity dams allowing for water compressibility and wave absorption at the reservoir bottom. This new analytical solution can take into account the effect of bottom material on seismic response of gravity dams. It is concluded that because the vertical component of ground motion causes significant hydrodynamic forces in the horizontal direction on a vertical upstream face, responses to the vertical component of ground motion are of special importance in analysis of concrete gravity dams subjected to earthquakes.
Abstract: The mountain road slope failures triggered by
earthquake activities and torrential rain namely to create the disaster.
Province Road No. 24 is a main route to the Wutai Township. The area
of the study is located at the mileages between 46K and 47K along the
road. However, the road has been suffered frequent damages as a result
of landslide and slope failures during typhoon seasons. An
understanding of the sliding behaviors in the area appears to be
necessary. Slope failures triggered by earthquake activities and heavy
rainfalls occur frequently. The study is to understand the mechanism
of slope failures and to look for the way to deal with the situation. In
order to achieve these objectives, this paper is based on theoretical and
structural geology data interpretation program to assess the potential
slope sliding behavior. The study showed an intimate relationship
between the landslide behavior of the slopes and the stratum materials,
based on structural geology analysis method to analysis slope stability
and finds the slope safety coefficient to predict the sites of destroyed
layer. According to the case study and parameter analyses results, the
slope mainly slips direction compared to the site located in the
southeast area. Find rainfall to result in the rise of groundwater level is
main reason of the landslide mechanism. Future need to set up
effective horizontal drain at corrective location, that can effective
restrain mountain road slope failures and increase stability of slope.
Abstract: There is increasing evidence that earthquakes produce electromagnetic signals observable at the surface in the extremely low to very low freqency (ELF - VLF) range often in advance to the main event. These precursors are candidates for prediction purposes. Laboratory experiments con´¼ürm that material under load emits an electromagnetic signature, the detailed generation mechanisms how- ever are not well understood yet.
Abstract: Stick models are widely used in studying the
behaviour of straight as well as skew bridges and viaducts subjected
to earthquakes while carrying out preliminary studies. The
application of such models to highly curved bridges continues to
pose challenging problems. A viaduct proposed in the foothills of the
Himalayas in Northern India is chosen for the study. It is having 8
simply supported spans @ 30 m c/c. It is doubly curved in horizontal
plane with 20 m radius. It is inclined in vertical plane as well. The
superstructure consists of a box section. Three models have been
used: a conventional stick model, an improved stick model and a 3D
finite element model. The improved stick model is employed by
making use of body constraints in order to study its capabilities. The
first 8 frequencies are about 9.71% away in the latter two models.
Later the difference increases to 80% in 50th mode. The viaduct was
subjected to all three components of the El Centro earthquake of May
1940. The numerical integration was carried out using the Hilber-
Hughes-Taylor method as implemented in SAP2000. Axial forces
and moments in the bridge piers as well as lateral displacements at
the bearing levels are compared for the three models. The maximum
difference in the axial forces and bending moments and
displacements vary by 25% between the improved and finite element
model. Whereas, the maximum difference in the axial forces,
moments, and displacements in various sections vary by 35%
between the improved stick model and equivalent straight stick
model. The difference for torsional moment was as high as 75%. It is
concluded that the stick model with body constraints to model the
bearings and expansion joints is not desirable in very sharp S curved
viaducts even for preliminary analysis. This model can be used only
to determine first 10 frequency and mode shapes but not for member
forces. A 3D finite element analysis must be carried out for
meaningful results.
Abstract: As the world move to the accomplishment of Performance Based Engineering philosophies in seismic design of Civil Engineering structures, new seismic design provisions require Structural Engineers to perform both static and dynamic analysis for the design of structures. While Linear Equivalent Static Analysis is performed for regular buildings up to 90m height in zone I and II, Dynamic Analysis should be performed for regular and irregular buildings in zone IV and V. Dynamic Analysis can take the form of a dynamic Time History Analysis or a linear Response Spectrum Analysis. In present study, Multi-storey irregular buildings with 20 stories have been modeled using software packages ETABS and SAP 2000 v.15 for seismic zone V in India. This paper also deals with the effect of the variation of the building height on the structural response of the shear wall building. Dynamic responses of building under actual earthquakes, EL-CENTRO 1949 and CHI-CHI Taiwan 1999 have been investigated. This paper highlights the accuracy and exactness of Time History analysis in comparison with the most commonly adopted Response Spectrum Analysis and Equivalent Static Analysis.
Abstract: In recent years, tuned mass damper (TMD) control systems for civil engineering structures have attracted considerable attention. This paper emphasizes on the application of particle swarm application (PSO) to design and optimize the parameters of the TMD control scheme for achieving the best results in the reduction of the building response under earthquake excitations. The Integral of the Time multiplied Absolute value of the Error (ITAE) based on relative displacement of all floors in the building is taken as a performance index of the optimization criterion. The problem of robustly TMD controller design is formatted as an optimization problem based on the ITAE performance index to be solved using the PSO technique which has a story ability to find the most optimistic results. An 11- story realistic building, located in the city of Rasht, Iran is considered as a test system to demonstrate effectiveness of the proposed method. The results analysis through the time-domain simulation and some performance indices reveals that the designed PSO based TMD controller has an excellent capability in reduction of the seismically excited example building.
Abstract: Natural disasters, including earthquake, kill many people around the world every year. Society rescue actions, which start after the earthquake and are called LAST in abbreviation, include locating, access, stabilization and transportation. In the present article, we have studied the process of local accessibility to the injured and transporting them to health care centers. With regard the heavy traffic load due to earthquake, the destruction of connecting roads and bridges and the heavy debris in alleys and street, which put the lives of the injured and the people buried under the debris in danger, accelerating the rescue actions and facilitating the accessibilities are of great importance, obviously. Tehran, the capital of Iran, is among the crowded cities in the world and is the center of extensive economic, political, cultural and social activities. Tehran has a population of about 9.5 millions and because of the immigration of people from the surrounding cities. Furthermore, considering the fact that Tehran is located on two important and large faults, a 6 Richter magnitude earthquake in this city could lead to the greatest catastrophe during the entire human history. The present study is a kind of review and a major part of the required information for it, has been obtained from libraries all of the rescue vehicles around the world, including rescue helicopters, ambulances, fire fighting vehicles and rescue boats, and their applied technology, and also the robots specifically designed for the rescue system and the advantages and disadvantages of them, have been investigated. The studies show that there is a significant relationship between the rescue team-s arrival time at the incident zone and the number of saved people; so that, if the duration of burial under debris 30 minutes, the probability of survival is %99.3, after a day is %81, after 2days is %19 and after 5days is %7.4. The exiting transport systems all have some defects. If these defects are removed, more people could be saved each hour and the preparedness against natural disasters is increased. In this study, transport system has been designed for the rescue team and the injured; which could carry the rescue team to the incident zone and the injured to the health care centers. In addition, this system is able to fly in the air and move on the earth as well; so that the destruction of roads and the heavy traffic load could not prevent the rescue team from arriving early at the incident zone. The system also has the equipment required firebird for debris removing, optimum transport of the injured and first aid.
Abstract: We study dynamic instability in high-rise steel moment
resisting frames (SMRFs) subjected to synthetic long-period ground
motions caused by hypothetical huge subduction earthquakes. Since
long duration as well as long dominant periods is a characteristic of
long-period ground motions, interstory drifts may enter the negative
postyield stiffness range many times when high-rise buildings are
subjected to long-period ground motions. Through the case studies of
9 high-rise SMRFs designed in accordance with the Japanese design
practice in 1980s, we demonstrate that drifting, or accumulation of
interstory drifts in one direction, occurs at the lower stories of the
SMRFs, if their natural periods are close to the dominant periods of the
long-period ground motions. The drifting led to residual interstory
drift ratio over 0.01, or to collapse if the design base shear was small.
Abstract: In the present article, effect of non-uniform excitation
of reservoir bottom on nonlinear response of concrete gravity dams is
considered. Anisotropic damage mechanics approach is used to model nonlinear behavior of mass concrete in 2D space. The tallest
monolith of Pine Flat dam is selected as a case study. The horizontal
and vertical components of 1967 Koyna earthquake is used to excite
the system. It is found that crest response and stresses within the dam body decrease significantly when the reservoir is excited nonuniformly. In addition, the crack profiles within the dam body and in vicinity of the neck decreases.
Abstract: In the territories where high-intensity
earthquakes are frequent is paid attention to the solving of the
seismic problems. In the paper are described two
computational model variants based on finite element method
of the construction with different subsoil simulation (rigid or
elastic subsoil) is used. For simulation and calculations
program system based on method final elements ANSYS was
used. Seismic responses calculations of residential building
structure were effected on loading characterized by
accelerogram for comparing with the responses spectra
method.
Abstract: Because of architectural condition and structure application, sometimes mass source and stiffness source are not coincidence, and the structure is irregular. The structure is also might be asymmetric as an asymmetric bracing in plan which leads to unbalance distribution of stiffness or because of unbalance distribution of the mass. Both condition lead to eccentricity and torsion in the structure. The deficiency of ordinary code to evaluate the performance of steel structures against earthquake has been caused designing based on performance level or capacity spectrum be used. By using the mentioned methods it is possible to design a structure that its behavior against different earthquakes be predictive. In this article 5- story buildings with different percentage of asymmetric which is because of stiffness changes have been designed. The static and dynamic nonlinear analysis under three acceleration recording has been done. Finally performance level of the structure has been evaluated.
Abstract: Analytical seismic response of multi-story building
supported on base isolation system is investigated under real
earthquake motion. The superstructure is idealized as a shear type
flexible building with lateral degree-of-freedom at each floor. The
force-deformation behaviour of the isolation system is modelled by
the bi-linear behaviour which can be effectively used to model all
isolation systems in practice. The governing equations of motion of
the isolated structural system are derived. The response of the system
is obtained numerically by step-by-method under three real recorded
earthquake motions and pulse motions associated in the near-fault
earthquake motion. The variation of the top floor acceleration, interstory
drift, base shear and bearing displacement of the isolated
building is studied under different initial stiffness of the bi-linear
isolation system. It was observed that the high initial stiffness of the
isolation system excites higher modes in base-isolated structure and
generate floor accelerations and story drift. Such behaviour of the
base-isolated building especially supported on sliding type of
isolation systems can be detrimental to sensitive equipment installed
in the building. On the other hand, the bearing displacement and base
shear found to reduce marginally with the increase of the initial
stiffness of the initial stiffness of the isolation system. Further, the
above behaviour of the base-isolated building was observed for
different parameters of the bearing (i.e. post-yield stiffness and
characteristic strength) and earthquake motions (i.e. real time history
as well as pulse type motion).
Abstract: In areas of low to moderate seismicity many building contents and equipment are not positively fixed to the floor or tied to adjacent walls. Under seismic induced horizontal vibration, such contents and equipment can suffer from damage by either overturning or impact associated with rocking. This paper focuses on the estimation of shock on typical contents and equipment due to rocking. A simplified analytical model is outlined that can be used to estimate the maximum acceleration on a rocking object given its basic geometric and mechanical properties. The developed model was validated against experimental results. The experimental results revealed that the maximum shock acceleration can be underestimated if the static stiffness of the materials at the interface between the rocking object and floor is used rather than the dynamic stiffness. Excellent agreement between the model and experimental results was found when the dynamic stiffness for the interface material was used, which was found to be generally much higher than corresponding static stiffness under different investigated boundary conditions of the cushion. The proposed model can be a beneficial tool in performing a rapid assessment of shock sensitive components considered for possible seismic rectification.
Abstract: In order to upgrade the seismic resistibility of structures and enhance the functionality of an isolator, a new base isolator called the multiple trench friction pendulum system (MTFPS) is proposed in this study. The proposed MTFPS isolator is composed of a trench concave surface and several intermediate sliding plates in two orthogonal directions. Mathematical formulations have been derived to examine the characteristics of the proposed MTFPS isolator possessing multiple intermediate sliding plates. By means of mathematical formulations, it can be inferred that the natural period and damping effect of the MTFPS isolator with several intermediate sliding plates can be altered continually and controllably during earthquakes. Furthermore, results obtained from shaking table tests demonstrate that the proposed isolator provides good protection to structures for prevention of damage from strong earthquakes.
Abstract: Many studies have been conducted for derivation of
attenuation relationships worldwide, however few relationships have
been developed to use for the seismic region of Iranian plateau and
only few of these studies have been conducted for derivation of
attenuation relationships for parameters such as uniform duration.
Uniform duration is the total time during which the acceleration is
larger than a given threshold value (default is 5% of PGA). In this
study, the database was same as that used previously by Ghodrati
Amiri et al. (2007) with same correction methods for earthquake
records in Iran. However in this study, records from earthquakes with
MS< 4.0 were excluded from this database, each record has
individually filtered afterward, and therefore the dataset has been
expanded. These new set of attenuation relationships for Iran are
derived based on tectonic conditions with soil classification into rock
and soil. Earthquake parameters were chosen to be
hypocentral distance and magnitude in order to make it easier to use
the relationships for seismic hazard analysis. Tehran is the capital
city of Iran wit ha large number of important structures. In this study,
a probabilistic approach has been utilized for seismic hazard
assessment of this city. The resulting uniform duration against return
period diagrams are suggested to be used in any projects in the area.
Abstract: In recent years, the number of natural disasters in the world has occurred frequently. After a strong earthquake occurs, multiple disasters due to tsunami, strong aftershocks or heavy snow can possible to occur. To prevent a secondary disaster and to save a life, the quick inspection of the damaged building is necessary. This paper investigated on a possibility of post earthquake quick inspection of damaged building by ordinary people which used the European Macro- Seismic Scale 1998 (EMS-98).
Abstract: This paper introduces the application of seismic wave method in earthquake prediction and early estimation. The advantages of the seismic wave method over the traditional earthquake prediction method are demonstrated. An example is presented in this study to show the accuracy and efficiency of using the seismic wave method in predicting a medium-sized earthquake swarm occurred in Wencheng, Zhejiang, China. By applying this method, correct predictions were made on the day after this earthquake swarm started and the day the maximum earthquake occurred, which provided scientific bases for governmental decision-making.