Abstract: The innovative fuzzy estimator is used to estimate the
ground motion acceleration of the retaining structure in this study. The
Kalman filter without the input term and the fuzzy weighting recursive
least square estimator are two main portions of this method. The
innovation vector can be produced by the Kalman filter, and be
applied to the fuzzy weighting recursive least square estimator to
estimate the acceleration input over time. The excellent performance
of this estimator is demonstrated by comparing it with the use of
difference weighting function, the distinct levels of the measurement
noise covariance and the initial process noise covariance. The
availability and the precision of the proposed method proposed in this
study can be verified by comparing the actual value and the one
obtained by numerical simulation.
Abstract: Buckling-Restrained Braced Frame system(BRBFs)
are a new type of steel seismic-load-resisting system that has found
use in several countries because of its efficiency and its promise of
seismic performance far superior to that of conventional braced
frames. The system is addressed in the 2005 edition of the AISC
Seismic Provisions for Structural Steel Buildings, also a set of design
provisions has been developed by NEHRP. This report illustrates the
seismic design of buckling restrained braced frames and compares
the result of design in the application of earthquake load for ordinary
bracing systems and buckling restrained bracing systems to see the
advantage and disadvantages of this new type of seismic resisting
system in comparison with the old Ordinary Concentric Braced
Frame systems (OCBFs); they are defined by the provisions
governing their design.
Abstract: The seismic vulnerability of an urban area is of a great
deal for local authorities especially those facing earthquakes. So, it is
important to have an efficient tool to assess the vulnerability of
existing buildings. The use of the VIP (Vulnerability Index Program)
and the GIS (Geographic Information System) let us to identify the
most vulnerable districts of an urban area.
The use of the vulnerability index method lets us to assess the
vulnerability of the center town of Blida (Algeria) which is a
historical town and which has grown enormously during the last
decades. In this method, three levels of vulnerability are defined. The
GIS has been used to build a data base in order to perform different
thematic analyses. These analyses show the seismic vulnerability of
Blida.
Abstract: In this survey the process of crack propagation at the
toe of concrete gravity dam is investigated by applying principals
and criteria of linear elastic fracture mechanic. Simulating process of
earthquake conditions for three models of dam with different
geometrical condition, in empty reservoir under plain stress is
calculated through special fracture mechanic software FRANNC2D
[1] for determining fracture mechanic criteria. The outcomes showed
that in spite of the primary expectations, the simultaneous existence
of fillet in both toe and heel area (model 3), the rate of maximum
principal stress has not been decreased; however, even the maximum
principal stress has increased, so it caused stress intensity factors
increase which is undesirable. On the other hand, the dam with heel
fillet has shown the best attitude and it is because of items like
decreasing the rates of maximum and minimum principal stresses and
also is related to decreasing the rates of stress intensity factors for 1st
& 2nd modes of the model.
Abstract: 53 college students answered questions regarding the circumstances in which they first heard about the news of Wenchuan earthquake or the news of their acceptance to college which took place approximately one year ago, and answered again two years later. The number of details recalled about their circumstances for both events was high and didn-t decline two years later. However, consistency in reported details over two years was low. Participants were more likely to construct central (e.g., Where were you?) than peripheral information (What were you wearing?), and the confidence of the central information was higher than peripheral information, which indicated that they constructed more when they were more confident.
Abstract: Historic religious buildings located in seismic areas
have developed different failure mechanisms. Simulation of failure
modes is done with computer programs through a nonlinear dynamic
analysis or simplified using the method of failure blocks. Currently
there are simulation methodologies of failure modes based on the
failure rigid blocks method only for Roman Catholic churches type.
Due to differences of shape in plan, elevation and construction
systems between Orthodox churches and Catholic churches, for the
first time there were initiated researches in the development of this
simulation methodology for Orthodox churches. In this article are
presented the first results from the researches. The theoretical results
were compared with real failure modes recorded at an Orthodox
church from Banat region, severely damaged by earthquakes in
1991. Simulated seismic response, using a computer program based
on finite element method was confirmed by cracks after earthquakes.
The consolidation of the church was made according to these
theoretical results, realizing a rigid floor connecting all the failure
blocks.
Abstract: In this study, control performance of a smart base
isolation system consisting of a friction pendulum system (FPS) and a
magnetorheological (MR) damper has been investigated. A fuzzy
logic controller (FLC) is used to modulate the MR damper so as to
minimize structural acceleration while maintaining acceptable base
displacement levels. To this end, a multi-objective optimization
scheme is used to optimize parameters of membership functions and
find appropriate fuzzy rules. To demonstrate effectiveness of the
proposed multi-objective genetic algorithm for FLC, a numerical
study of a smart base isolation system is conducted using several
historical earthquakes. It is shown that the proposed method can find
optimal fuzzy rules and that the optimized FLC outperforms not only a
passive control strategy but also a human-designed FLC and a
conventional semi-active control algorithm.
Abstract: Earthquakes produce some of the most violent loading
situations that a structure can be subjected to and if a structure fails
under these loads then inevitably human life is put at risk. One of the
most common methods by which a structure fails under seismic
loading is at the connection of structural elements. The research
presented in this paper investigates the interlock systems as a novel
method for building structures. The main objective of this
experimental study wasto determine the dynamic characteristics and
the seismic behaviour of the proposed structures compared to
conventional structural systemsduring seismic motions. Results of
this study indicate that the interlock mechanism of the panels
influences the behaviour of lateral load-resisting systems of the
structures during earthquakes, contributing to better structural
flexibility and easier maintenance.
Abstract: Considering the merits and limitations of energy dissipation system, seismic isolation system and suspension system, a new earthquake resistant system is proposed and is demonstrated numerically through a frame-core structure. Base isolators and story isolators are installed in the proposed system. The former “isolates" the frame from the foundation and the latter “separates" the frame from the center core. Equations of motion are formulated to study the response of the proposed structural system to strong earthquake motion. As compared with the fixed-base building system, the proposed structural system shows substantial reduction on structural response.
Abstract: Because of the reservoir effect, dynamic analysis of concrete dams is more involved than other common structures. This problem is mostly sourced by the differences between reservoir water, dam body and foundation material behaviors. To account for the reservoir effect in dynamic analysis of concrete gravity dams, two methods are generally employed. Eulerian method in reservoir modeling gives rise to a set of coupled equations, whereas in Lagrangian method, the same equations for dam and foundation structure are used. The Purpose of this paper is to evaluate and study possible advantages and disadvantages of both methods. Specifically, application of the above methods in the analysis of dam-foundationreservoir systems is leveraged to calculate the hydrodynamic pressure on dam faces. Within the frame work of dam- foundationreservoir systems, dam displacement under earthquake for various dimensions and characteristics are also studied. The results of both Lagrangian and Eulerian methods in effects of loading frequency, boundary condition and foundation elasticity modulus are quantitatively evaluated and compared. Our analyses show that each method has individual advantages and disadvantages. As such, in any particular case, one of the two methods may prove more suitable as presented in the results section of this study.
Abstract: This paper presents probabilistic horizontal seismic
hazard assessment of Naghan, Iran. It displays the probabilistic
estimate of Peak Ground Horizontal Acceleration (PGHA) for the
return period of 475, 950 and 2475 years. The output of the
probabilistic seismic hazard analysis is based on peak ground
acceleration (PGA), which is the most common criterion in designing
of buildings. A catalogue of seismic events that includes both
historical and instrumental events was developed and covers the
period from 840 to 2009. The seismic sources that affect the hazard
in Naghan were identified within the radius of 200 km and the
recurrence relationships of these sources were generated by Kijko
and Sellevoll. Finally Peak Ground Horizontal Acceleration (PGHA)
has been prepared to indicate the earthquake hazard of Naghan for
different hazard levels by using SEISRISK III software.
Abstract: On March 11, 2011, the East coast of Japan was hit by
one of the strongest earthquakes in history, followed by a devastating
tsunami. Although most lifelines, infrastructure, and public facilities
have been restored gradually, recovery efforts in terms of disposal of
disaster waste and revival of primary industry are lagging. This study
presents a summary of the damage inflicted by the earthquake and the
current status of reconstruction in the disaster area. Moreover, we
discuss the current trends and future perspectives on recently
implemented eco-friendly reconstruction projects and focus on the
pro-environmental behavior of disaster victims which is emerging as a
result of the energy shortage after the earthquake. Finally, we offer
ideas for initiatives for the next stage of the reconstruction policies.
Abstract: In this paper the vibration behaviors of a structure equipped with a tuned liquid column damper (TLCD) under a harmonic type of earthquake loading are studied. However, due to inherent nonlinear liquid damping, it is no doubt that a great deal of computational effort is required to search the optimum parameters of the TLCD, numerically. Therefore by linearization the equation of motion of the single degree of freedom structure equipped with the TLCD, the closed form solutions of the TLCD-structure system are derived. To find the reliability of the analytical method, the results have been compared with other researcher and have good agreement. Further, the effects of optimal design parameters such as length ratio and mass ratio on the performance of the TLCD for controlling the responses of a structure are investigated by using the harmonic type of earthquake excitation. Finally, the Citicorp Center which has a very flexible structure is used as an example to illustrate the design procedure for the TLCD under the earthquake excitation.
Abstract: The cost of damage to the non-structural systems in
critical facilities like nuclear power plants and hospitals can exceed
80% of the total cost of damage during an earthquake. The failure of
nonstructural components, especially, piping systems led to leakage of
water and subsequent shut-down of hospitals immediately after the
event. Consequently, the evaluation of performance of these types of
structural configurations has become necessary to mitigate the risk and
to achieve reliable designs.
This paper focuses on a methodology to evaluate the static and
dynamic characteristics of complex actual piping system based on
NFPA-13 and SMACNA guidelines. The result of this study revealed
that current piping system subjected to design lateral force and design
spectrum based on UBC-97 was failed in both cases and mode shapes
between piping system and building structure were very different
Abstract: In the real application of active control systems to
mitigate the response of structures subjected to sever external
excitations such as earthquake and wind induced vibrations, since the
capacity of actuators is limited then the actuators saturate. Hence, in
designing controllers for linear and nonlinear structures under sever
earthquakes, the actuator saturation should be considered as a
constraint. In this paper optimal design of active controllers for
nonlinear structures by considering the actuator saturation has been
studied. To this end a method has been proposed based on defining
an optimization problem which considers the minimizing of the
maximum displacement of the structure as objective when a limited
capacity for actuator has been used as a constraint in optimization
problem. To evaluate the effectiveness of the proposed method, a
single degree of freedom (SDF) structure with a bilinear hysteretic
behavior has been simulated under a white noise ground acceleration
of different amplitudes. Active tendon control mechanism, comprised
of pre-stressed tendons and an actuator, and extended nonlinear
Newmark method based instantaneous optimal control algorithm
have been used as active control mechanism and algorithm. To
enhance the efficiency of the controllers, the weights corresponding
to displacement, velocity, acceleration and control force in the
performance index have been found by using the Distributed Genetic
Algorithm (DGA). According to the results it has been concluded
that the proposed method has been effective in considering the
actuator saturation in designing optimal controllers for nonlinear
frames. Also it has been shown that the actuator capacity and the
average value of required control force are two important factors in
designing nonlinear controllers for considering the actuator
saturation.
Abstract: Transportation is of great importance in the current
life of human beings. The transportation system plays many roles,
from economical development to after-catastrophe aids such as
rescue operation in the first hours and days after an earthquake. In
after earthquakes response phase, transportation system acts as a
basis for ground operations including rescue and relief operation,
food providing for victims and etc. It is obvious that partial or
complete obstruction of this system results in the stop of these
operations. Bridges are one of the most important elements of
transportation network. Failure of a bridge, in the most optimistic
case, cuts the relation between two regions and in more developed
countries, cuts the relation of numerous regions. In this paper, to
evaluate the vulnerability and estimate the damage level of Tehran
bridges, HAZUS method, developed by Federal Emergency
Management Agency (FEMA) with the aid of National Institute of
Building Science (NIBS), is used for the first time in Iran. In this
method, to evaluate the collapse probability, fragility curves are
used. Iran is located on seismic belt and thus, it is vulnerable to
earthquakes. Thus, the study of the probability of bridge collapses, as
an important part of transportation system, during earthquakes is of
great importance. The purpose of this study is to provide fragility
curves for Gisha Bridge, one of the longest steel bridges in Tehran,
as an important lifeline element. Besides, the damage probability for
this bridge during a specific earthquake, introduced as scenario
earthquakes, is calculated. The fragility curves show that for the
considered scenario, the probability of occurrence of complete
collapse for the bridge is 8.6%.
Abstract: From past many decades human beings are suffering
from plethora of natural disasters. Occurrence of disasters is a
frequent process; it changes conceptual myths as more and more
advancement are made. Although we are living in technological era
but in developing countries like Pakistan disasters are shaped by
socially constructed roles. The need is to understand the most
vulnerable group of society i.e. females; their issues are complex in
nature because of undermined gender status in the society. There is a
need to identify maximum issues regarding females and to enhance
the achievement of millennium development goals (MDGs). Gender
issues are of great concern all around the globe including Pakistan.
Here female visibility in society is low, and also during disasters, the
failure to understand the reality that concentrates on double burden
including productive and reproductive care. Women have to
contribute a lot in society so we need to make them more disaster
resilient. For this non-structural measures like awareness, trainings
and education must be carried out. In rural and in urban settings in
any disaster like earthquake or flood, elements like gender
perspective, their age, physical health, demographic issues contribute
towards vulnerability. In Pakistan the gender issues in disasters were
of less concern before 2005 earthquake and 2010 floods. Significant
achievements are made after 2010 floods when gender and child cell
was created to provide all facilities to women and girls. The aim of
the study is to highlight all necessary facilities in a disaster to build
coping mechanism in females from basic rights till advance level
including education.
Abstract: In order to improve the effect of isolation structure, the
principles and behaviours of the base-isolation system are studied, and
the types and characteristics of the base-isolation are also discussed.
Compared to the traditional aseismatic structures, the base isolation
structures decrease the seismic response obviously: the total structural
aseismatic value decreases to 1/4-1/32 and the seismic shear stress in
the upper structure decreases to 1/14-1/23. In the huge seism, the
structure can have an obvious aseismatic effect.
Abstract: Probabilistic characteristics of seismic responses of the
Partially Restrained connection rotation (PRCR) and panel zone
deformation (PZD) installed in older steel moment frames were
investigated in accordance with statistical inference in
decision-making process. The 4, 6 and 8 story older steel moment
frames with clip angle and T-stub connections were designed and
analyzed using 2%/50yrs ground motions in four cities of the
Mid-America earthquake region. The probability density function and
cumulative distribution function of PRCR and PZD were determined
by the goodness-of-fit tests based on probabilistic parameters
measured from the results of the nonlinear time-history analyses. The
obtained probabilistic parameters and distributions can be used to find
out what performance level mainly PR connections and panel zones
satisfy and how many PR connections and panel zones experience a
serious damage under the Mid-America ground motions.
Abstract: The dominant judgment for earthquake damaged reinforced concrete (RC) structures is to rebuild them with the new ones. Consequently, this paper estimates if there is chance to repair earthquake RC beams and obtain economical contribution to modern day society. Therefore, the totally damaged (damaged in shear under cyclic load) reinforced concrete (RC) beams repaired and strengthened by externally bonded carbon fibre reinforced polymer (CFRP) strips in this study. Four specimens, apart from the reference beam, were separated into two distinct groups. Two experimental beams in the first group primarily tested up to failure then appropriately repaired and strengthened with CFRP strips. Two undamaged specimens from the second group were not repaired but strengthened by the identical strengthening scheme as the first group for comparison. This study studies whether earthquake damaged RC beams that have been repaired and strengthened will validate similar strength and behavior to equally strengthened, undamaged RC beams. Accordingly, a strength correspondence according to strengthened specimens was acquired for the repaired and strengthened specimens. Test results confirmed that repair and strengthening, which were estimated in the experimental program, were effective for the specimens with the cracking patterns considered in the experimental program.