Abstract: This paper presents the comparison study of current control techniques for shunt active power filter. The hysteresis current control, the delta modulation control and the carrier-based PWM control are considered in the paper. The synchronous detection method is used to calculate the reference currents for shunt active power filter. The simulation results show that the carrier-based PWM control technique provides the minimum %THD value of the source currents compared with other comparable techniques after compensation. However, the %THD values of all three techniques can follow the IEEE std.519-1992.
Abstract: Active power filter continues to be a powerful tool to control harmonics in power systems thereby enhancing the power quality. This paper presents a fuzzy tuned PID controller based shunt active filter to diminish the harmonics caused by non linear loads like thyristor bridge rectifiers and imbalanced loads. Here Fuzzy controller provides the tuning of PID, based on firing of thyristor bridge rectifiers and variations in input rms current. The shunt APF system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Simulation studies are carried out with non linear loads like thyristor bridge rectifier along with unbalanced loads and the results proved that the APF along with fuzzy tuned PID controller work flawlessly for different firing angles of non linear load.
Abstract: This paper puts forward one kind of air-fuel ratio
control method with PI controller. With the help of
MATLAB/SIMULINK software, the mathematical model of air-fuel
ratio control system for distributorless CNG engine is constructed.
The objective is to maintain cylinder-to-cylinder air-fuel ratio at a
prescribed set point, determined primarily by the state of the Three-
Way-Catalyst (TWC), so that the pollutants in the exhaust are
removed with the highest efficiency. The concurrent control of airfuel
under transient conditions could be implemented by Proportional
and Integral (PI) controller. The simulation result indicates that the
control methods can easily eliminate the air/fuel maldistribution and
maintain the air/fuel ratio at the stochiometry within minimum
engine events.
Abstract: This article presents a current-mode universal biquadratic filter. The proposed circuit can apparently provide standard functions of the biquad filter: low-pass, high-pass, bandpass, band-reject and all-pass functions. The circuit uses 4 current controlled transconductance amplifiers (CCTAs) and 2 grounded capacitors. In addition, the pole frequency and quality factor can be adjusted by electronic method by adjusting the bias currents of the CCTA. The proposed circuit uses only grounded capacitors without additional external resistors, the proposed circuit is considerably appropriate to further developing into an integrated circuit. The results of PSPICE simulation program are corresponding to the theoretical analysis.
Abstract: This paper presents modeling and analysis of 12-phase distribution static compensator (DSTATCOM), which is capable of balancing the source currents in spite of unbalanced loading and phase outages. In addition to balance the supply current, the power factor can be set to a desired value. The theory of instantaneous symmetrical components is used to generate the twelve-phase reference currents. These reference currents are then tracked using current controlled voltage source inverter, operated in a hysteresis band control scheme. An ideal compensator in place of physical realization of the compensator is used. The performance of the proposed DTATCOM is validated through MATLAB simulation and detailed simulation results are given.
Abstract: Current mode circuits like current conveyors are
getting significant attention in current analog ICs design due to their
higher band-width, greater linearity, larger dynamic range, simpler
circuitry, lower power consumption and less chip area. The second
generation current controlled conveyor (CCCII) has the advantage of
electronic adjustability over the CCII i.e. in CCCII; adjustment of the
X-terminal intrinsic resistance via a bias current is possible. The
presented approach is based on the CMOS implementation of second
generation positive (CCCII+), negative (CCCII-) and dual Output
Current Controlled Conveyor (DOCCCII) and its application as
Universal filter. All the circuits have been designed and simulated
using 65nm CMOS technology model parameters on Cadence
Virtuoso / Spectre using 1V supply voltage. Various simulations have
been carried out to verify the linearity between output and input
ports, range of operation frequency, etc. The outcomes show good
agreement between expected and experimental results.
Abstract: This article presents a resistorless current-mode firstorder allpass filter based on second generation current controlled current conveyors (CCCIIs). The features of the circuit are that: the pole frequency can be electronically controlled via the input bias current: the circuit description is very simple, consisting of 2 CCCIIs and single grounded capacitor, without any external resistors and component matching requirements. Consequently, the proposed circuit is very appropriate to further develop into an integrated circuit. Low input and high output impedances of the proposed configuration enable the circuit to be cascaded in current-mode without additional current buffers. The PSpice simulation results are depicted. The given results agree well with the theoretical anticipation. The application example as a current-mode quadrature oscillator is included.
Abstract: This paper presents a fuzzy logic controlled shunt
active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a
simple method for the calculation of the reference compensation current based of Fast Fourier Transform. This presented filter is able
to operate in both balanced and unbalanced load conditions. A fuzzy
logic based current controller strategy is used to regulate the filter current and hence ensure harmonic free supply current. The validity
of the presented approach in harmonic mitigation is verified via
simulation results of the proposed test system under different loading
conditions.
Abstract: This paper is described one of the intelligent control method in Autonomous systems, which is called fuzzy control to correct the three wheel omnidirectional robot movement while it make mistake to catch the target. Fuzzy logic is especially advantageous for problems that can not be easily represented by mathematical modeling because data is either unavailable, incomplete or the process is too complex. Such systems can be easily up grated by adding new rules to improve performance or add new features. In many cases , fuzzy control can be used to improve existing traditional controller systems by adding an extra layer of intelligence to the current control method. The fuzzy controller designed here is more accurate and flexible than the traditional controllers. The project is done at MRL middle size soccer robot team.
Abstract: This paper aims to give a full study of the dynamic
behavior of a mono-phase active power filter. First, the principle of
the parallel active power filter will be introduced. Then, a
dimensioning procedure for all its components will be explained in
detail, such as the input filter, the current and voltage controllers.
This active power filter is simulated using OrCAD program showing
the validity of the theoretical study.
Abstract: The realization of current-mode quadrature oscillators
using current controlled current conveyor transconductance
amplifiers (CCCCTAs) and grounded capacitors is presented. The
proposed oscillators can provide 2 sinusoidal output currents with 90º
phase difference. It is enabled non-interactive dual-current control for
both the condition of oscillation and the frequency of oscillation.
High output impedances of the configurations enable the circuit to be
cascaded without additional current buffers. The use of only
grounded capacitors is ideal for integration. The circuit performances
are depicted through PSpice simulations, they show good agreement
to theoretical anticipation.
Abstract: Most high-performance ac drives utilize a current
controller. The controller switches a voltage source inverter (VSI)
such that the motor current follows a set of reference current
waveforms. Fixed-band hysteresis (FBH) current control has been
widely used for the PWM inverter. We want to apply the same
controller for the PWM AC chopper. The aims of the controller is to
optimize the harmonic content at both input and output sides, while
maintaining acceptable losses in the ac chopper and to control in
wide range the fundamental output voltage. Fixed band controller has
been simulated and analyzed for a single-phase AC chopper and are
easily extended to three-phase systems. Simulation confirmed the
advantages and the excellent performance of the modulation method
applied for the AC chopper.
Abstract: The excellent suitability of the externally excited synchronous
machine (EESM) in automotive traction drive applications
is justified by its high efficiency over the whole operation range and
the high availability of materials. Usually, maximum efficiency is
obtained by modelling each single loss and minimizing the sum of all
losses. As a result, the quality of the optimization highly depends on
the precision of the model. Moreover, it requires accurate knowledge
of the saturation dependent machine inductances. Therefore, the
present contribution proposes a method to minimize the overall losses
of a salient pole EESM and its inverter in steady state operation based
on measurement data only. Since this method does not require any
manufacturer data, it is well suited for an automated measurement
data evaluation and inverter parametrization. The field oriented control
(FOC) of an EESM provides three current components resp. three
degrees of freedom (DOF). An analytic minimization of the copper
losses in the stator and the rotor (assuming constant inductances) is
performed and serves as a first approximation of how to choose the
optimal current reference values. After a numeric offline minimization
of the overall losses based on measurement data the results are
compared to a control strategy that satisfies cos (ϕ) = 1.
Abstract: This paper, a simple continuous conduction mode (CCM) pulse-width-modulated (PWM) controller for high power factor boost converters is introduced. The duty ratios were obtained by the comparison of a sensed signal from inductor current or switch current and a negative slope ramp carrier waveform in each switching period. Due to the proposed control requires only the inductor current or switch current sensor and the output voltage sensor, its circuit implementation was very simple. To verify the proposed control, the circuit experimentation of a 350 W boost converter with the proposed control was applied. From the results, the input current waveform was shaped to be closely sinusoidal, implying high power factor and low harmonics.
Abstract: This article presents a voltage-mode universal
biquadratic filter performing simultaneous 3 standard functions: lowpass,
high-pass and band-pass functions, employing differential
different current conveyor (DDCC) and current controlled current
conveyor (CCCII) as active element. The features of the circuit are
that: the quality factor and pole frequency can be tuned independently
via the input bias currents: the circuit description is very simple,
consisting of 1 DDCC, 2 CCCIIs, 2 electronic resistors and 2
grounded capacitors. Without requiring component matching
conditions, the proposed circuit is very appropriate to further develop
into an integrated circuit. The PSPICE simulation results are
depicted. The given results agree well with the theoretical
anticipation.
Abstract: In this paper, a modified CCCII is presented. We have used a current mirror with low supply voltage. This circuit is operated at low supply voltage of ±1V. Tspice simulations for TSMC 0.18μm CMOS Technology has shown that the current and voltage bandwidth are respectively 3.34GHz and 4.37GHz, and parasitic resistance at port X has a value of 169.320 for a control current of 120μA. In order to realize this circuit, we have implemented in this first step a universal current mode filter where the frequency can reach the 134.58MHz. In the second step, we have implemented two simulated inductors: one floating and the other grounded. These two inductors are operated in high frequency and variable depending on bias current I0. Finally, we have used the two last inductors respectively to implement two sinusoidal oscillators domains of frequencies respectively: [470MHz, 692MHz], and [358MHz, 572MHz] for bias currents I0 [80μA, 350μA].