Abstract: Passive resonant vibration absorbers are among the most widely used dynamic control systems in civil engineering. They typically consist in a single-degree-of-freedom mechanical appendage of the main structure, tuned to one structural target mode through frequency and damping optimization. One classical scheme is the pendulum absorber, whose mass is constrained to move along a curved trajectory and is damped by viscous dashpots. Even though the principle is well known, the search for improved arrangements is still under way. In recent years this investigation inspired a type of bidirectional pendulum absorber (BPA), consisting of a mass constrained to move along an optimal three-dimensional (3D) concave surface. For such a BPA, the surface principal curvatures are designed to ensure a bidirectional tuning of the absorber to both principal modes of the main structure, while damping is produced either by horizontal viscous dashpots or by vertical friction dashpots, connecting the BPA to the main structure. In this paper, a variant of BPA is proposed, where damping originates from the variable tangential friction force which develops between the pendulum mass and the 3D surface as a result of a spatially-varying friction coefficient pattern. Namely, a friction coefficient is proposed that varies along the pendulum surface in proportion to the modulus of the 3D surface gradient. With such an assumption, the dissipative model of the absorber can be proven to be nonlinear homogeneous in the small displacement domain. The resulting homogeneous BPA (HBPA) has a fundamental advantage over conventional friction-type absorbers, because its equivalent damping ratio results independent on the amplitude of oscillations, and therefore its optimal performance does not depend on the excitation level. On the other hand, the HBPA is more compact than viscously damped BPAs because it does not need the installation of dampers. This paper presents the analytical model of the HBPA and an optimal methodology for its design. Numerical simulations of single- and multi-story building structures under wind and earthquake loads are presented to compare the HBPA with classical viscously damped BPAs. It is shown that the HBPA is a promising alternative to existing BPA types and that homogeneous tangential friction is an effective means to realize systems provided with amplitude-independent damping.
Abstract: This study investigates and develops the structural optimization method. The effect of size constraints on practical solution of reinforced concrete (RC) building structure with shear wall is proposed. Cross-sections of beam and column, and thickness of shear wall are considered as design variables. The objective function to be minimized is total cost of the structure by using a simple and efficient automated MATLAB platform structural optimization methodology. With modification of mathematical formulations, the result is compared with optimal solution without size constraints. The most suitable combination of section sizes is selected as for the final design application based on linear static analysis. The findings of this study show that defining higher value of upper bound of sectional sizes significantly affects optimal solution, and defining of size constraints play a vital role in finding of global and practical solution during optimization procedures. The result and effectiveness of proposed method confirm the ability and efficiency of optimal solutions for 3D RC shear wall-frame structure.
Abstract: The advancement in various concrete ingredients like plasticizers, additives and fibers, etc. has enabled concrete technologists to develop many viable varieties of special concretes in recent decades. Such various varieties of concrete have significant enhancement in green as well as hardened properties of concrete. A prudent selection of appropriate type of concrete can resolve many design and application issues in construction projects. This paper focuses on usage of self-compacting concrete, high early strength concrete, structural lightweight concrete, fiber reinforced concrete, high performance concrete and ultra-high strength concrete in the structures. The modified properties of strength at various ages, flowability, porosity, equilibrium density, flexural strength, elasticity, permeability etc. need to be carefully studied and incorporated into the design of the structures. The paper demonstrates various mixture combinations and the concrete properties that can be leveraged. The selection of such products based on the end use of structures has been proposed in order to efficiently utilize the modified characteristics of these concrete varieties. The study involves mapping the characteristics with benefits and savings for the structure from design perspective. Self-compacting concrete in the structure is characterized by high shuttering loads, better finish, and feasibility of closer reinforcement spacing. The structural design procedures can be modified to specify higher formwork strength, height of vertical members, cover reduction and increased ductility. The transverse reinforcement can be spaced at closer intervals compared to regular structural concrete. It allows structural lightweight concrete structures to be designed for reduced dead load, increased insulation properties. Member dimensions and steel requirement can be reduced proportionate to about 25 to 35 percent reduction in the dead load due to self-weight of concrete. Steel fiber reinforced concrete can be used to design grade slabs without primary reinforcement because of 70 to 100 percent higher tensile strength. The design procedures incorporate reduction in thickness and joint spacing. High performance concrete employs increase in the life of the structures by improvement in paste characteristics and durability by incorporating supplementary cementitious materials. Often, these are also designed for slower heat generation in the initial phase of hydration. The structural designer can incorporate the slow development of strength in the design and specify 56 or 90 days strength requirement. For designing high rise building structures, creep and elasticity properties of such concrete also need to be considered. Lastly, certain structures require a performance under loading conditions much earlier than final maturity of concrete. High early strength concrete has been designed to cater to a variety of usages at various ages as early as 8 to 12 hours. Therefore, an understanding of concrete performance specifications for special concrete is a definite door towards a superior structural design approach.
Abstract: In this paper, an optimization procedure is applied for 3D Reinforced concrete building structure with shear wall. In the optimization problem, cross sections of beams, columns and shear wall dimensions are considered as design variables and the optimal cross sections can be derived to minimize the total cost of the structure. As for final design application, the most suitable sections are selected to satisfy ACI 318-14 code provision based on static linear analysis. The validity of the method is examined through numerical example of 15 storied 3D RC building with shear wall. This optimization method is expected to assist in providing a useful reference in design early stage, and to be an effective and powerful tool for structural design of RC shear wall structures.
Abstract: There is no reinforcement example for the renovation of the vertical and horizontal extension to existing building structures which is a shear wall type in apartment units in Korea. Among these existing structures, the structures which are shear wall type are rare overseas, while Korea has many shear wall apartment units. Recently, in Korea, a few researchers are trying to confirm the possibility of the vertical extension in existing building with shear walls. This study evaluates the possibility of the renovation by applying performance-based seismic design to existing buildings with shear walls in the analysis phase of the structure. In addition, force-based seismic design, used by general structural engineers in Korea, is carried out to compare the amount of reinforcement of walls, which is a main component of wall structure. As a result, we suggest that performance-based design obtains more economical advantages than force-based seismic design.
Abstract: Building structures are subjected to both horizontal and vertical ground motions during earthquakes, but only the horizontal ground motion has been extensively studied and considered in design. Most of the prevailing seismic codes assume the vertical component to be 1/2 to 2/3 of the horizontal one. In order to understand the building responses from vertical ground motions, many earthquakes records are studied in this paper. System identification methods (ARX Model) are used to analyze the strong motions and to find out the characteristics of the vertical amplification factors and the natural frequencies of buildings. Analysis results show that the vertical amplification factors for high-rise buildings and low-rise building are 1.78 and 2.52 respectively, and the average vertical amplification factor of all buildings is about 2. The relationship between the vertical natural frequency and building height was regressed to a suggested formula in this study. The result points out an important message; the taller the building is, the greater chance of resonance of vertical vibration on the building will be.
Abstract: A wide range of health effects among occupants are associated with the exposure to bioaerosols from fungal sources. Although the accurate role of these aerosols in causing the symptoms and diseases is poorly understood, the important effect of bioaerosol exposure on human health is well recognized. Thus, there is a need to determine all of the contributing factors related to the concentration of fungi in indoor air. In this study, we reviewed and summarized the different factors affecting the concentrations of viable fungi in school buildings. The literature research was conducted using Pubmed and Google Scholar. In addition, we searched the lists of references of selected articles. According to the literature, the main factors influencing the concentration of viable fungi in the school buildings are moisture damage in building structures, the season (temperature and humidity conditions), the type and rate of ventilation, the number and activities of occupants and diurnal variations. This study offers valuable information that can be used in the interpretation of the fungal analysis and to decrease microbial exposure by reducing known sources and/or contributing factors. However, more studies of different local factors contributing to the human microbial exposure in school buildings—as well as other type of buildings and different indoor environments—are needed.
Abstract: The optimal design procedure of buckling restrained braces (BRBs) in reinforced concrete (RC) building structures can provide the distribution of horizontal stiffness of BRBs at each story, which minimizes story drift response of the structure under the constraint of specified total stiffness of BRBs. In this paper, a simple rule is proposed to convert continuous horizontal stiffness of BRBs into sectional sizes of BRB which are available from standardized section list assuming realistic structural design stage.
Abstract: In the construction of a building, it is necessary to minimize construction period and secure enough work space for stacking of materials during the construction especially in city area. In this manner, various top-down construction methods have been developed and widely used in Korea. This paper investigates the stress variation of underground structure of a building constructed by using SPS (Strut as Permanent System) known as a top-down method in Korea through an analytical approach. Various types of earth pressure distribution related to ground condition were considered in the structural analysis of an example structure at each step of the excavation. From the analysis, the most high member force acting on beams was found when the ground type was medium sandy soil and a stress concentration was found in corner area.
Abstract: The present paper aims at evaluating the response of three-dimensional buildings with in-plan stiffness irregularities that have been subjected to two-way excitation ground motion records simultaneously. This study is broadly-based fragility assessment with greater emphasis on structural response at in-plan flexible and stiff sides. To this end, three type of three-dimensional 5-story steel building structures with stiffness eccentricities, were subjected to extensive nonlinear incremental dynamic analyses (IDA) utilizing Ibarra-Krawinkler deterioration models. Fragility assessment was implemented for different configurations of braces to investigate the losses in buildings with center of resisting (CR) eccentricities.
Abstract: The structural system of wooden house by two-by-four method is widely adopted in any countries, and a various type of vibration control system for building structures has been developed on country with frequent earthquake. In this study, a vibration control device called “Scaling Frame” (SF) is suggested, and which is applied to wooden two-by-four method structures. This paper performs the experimental study to investigate the restoring force characteristics of two-by-four with SF device installed. The seismic resistant performance is estimated experimentally, and also the applicability and effectiveness are discussing.
Abstract: Building Information Modeling (BIM) is a holistic documentation process for operational visualization, design coordination, estimation and project scheduling. BIM software defines objects parametrically and it is a tool for virtual reality. Primary advantage of implementing BIM is the visual coordination of the building structure and systems such as Mechanical, Electrical and Plumbing (MEP) and it also identifies the possible conflicts between the building systems. This paper is an attempt to develop a risk based BIM model which would highlight the primary advantages of application of BIM pertaining to urban infrastructure transportation project. It has been observed that about 40% of the Architecture, Engineering and Construction (AEC) companies use BIM but primarily for their outsourced projects. Also, 65% of the respondents agree that BIM would be used quiet strongly for future construction projects in India. The 3D models developed with Revit 2015 software would reduce co-ordination problems amongst the architects, structural engineers, contractors and building service providers (MEP). Integration of risk management along with BIM would provide enhanced co-ordination, collaboration and high probability of successful completion of the complex infrastructure transportation project within stipulated time and cost frame.
Abstract: Energy consumption data, in particular those involving
public buildings, are impacted by many factors: the building structure,
climate/environmental parameters, construction, system operating
condition, and user behavior patterns. Traditional methods for data
analysis are insufficient. This paper delves into the data mining
technology to determine its application in the analysis of building
energy consumption data including energy consumption prediction,
fault diagnosis, and optimal operation. Recent literature are reviewed
and summarized, the problems faced by data mining technology in the
area of energy consumption data analysis are enumerated, and research
points for future studies are given.
Abstract: In this study, static and dynamic responses of a typical
reinforced concrete solid slab, designed to British Standard (BS 8110:
1997) and under self and live loadings for dance halls are reported.
Linear perturbation analysis using finite element method was
employed for modal, impulse loading and frequency response
analyses of the slab under the aforementioned loading condition.
Results from the static and dynamic analyses, comprising of the slab
fundamental frequencies and mode shapes, dynamic amplification
factor, maximum deflection, stress distributions among other
valuable outcomes are presented and discussed. These were gauged
with the limiting provisions in the design code with a view of
justifying valid optimization objective function for the structure that
can ensure both adequate strength and economical section for large
clear span slabs. This is necessary owing to the continued increase in
cost of erecting building structures and the squeeze on public finance
globally.
Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: This article presents the main results of a numerical
investigation on the uncertainty of dynamic response of structures
with statistically correlated random damping Gamma distributed. A
computational method based on a Linear Statistical Model (LSM) is
implemented to predict second order statistics for the response of a
typical industrial building structure. The significance of random
damping with correlated parameters and its implications on the
sensitivity of structural peak response in the neighborhood of a
resonant frequency are discussed in light of considerable ranges of
damping uncertainties and correlation coefficients. The results are
compared to those generated using Monte Carlo simulation
techniques. The numerical results obtained show the importance of
damping uncertainty and statistical correlation of damping
coefficients when obtaining accurate probabilistic estimates of
dynamic response of structures. Furthermore, the effectiveness of the
LSM model to efficiently predict uncertainty propagation for
structural dynamic problems with correlated damping parameters is
demonstrated.
Abstract: Environmental and functional conditions, sometimes,
necessitate the architectural plan of the building to be asymmetric,
and this result in an asymmetric structure. In such cases finding an
optimal pattern for locating the components of lateral load bearing
system, including shear walls, in the building’s plan is desired. In
case of shear wall in addition to the location the shape of the wall
cross-section is also an effective factor. Various types of shear walls
and their proper layout might come effective in better stiffness
distribution and more appropriate seismic response of the building.
Several studies have been conducted in the context of analysis and
design of shear walls; however, few studies have been performed on
making decisions for the location and form of shear walls in multistory
buildings, especially those with irregular plan. In this study, an
attempt has been made to obtain the most reliable seismic behavior of
multi-story reinforced concrete vertically chamfered buildings by
using more appropriate shear walls form and arrangement in 7-, 10-,
12-, and 15-stoy buildings. The considered forms and arrangements
include common rectangular walls and L-, T-, U- and Z-shaped plan,
located as the core or in the outer frames of the building structure.
Comparison of seismic behaviors of the buildings, including
maximum roof displacement and particularly formation of plastic
hinges and their distribution in the buildings’ structures, have been
done based on the results of a series of nonlinear time history
analyses, by using a set of selected earthquake records. Results show
that shear walls with U-shaped cross-section, placed as the building
central core, and also walls with Z-shaped cross-section, placed at the
corners give the building more reliable seismic behavior.
Abstract: When high strength reinforced concrete is exposed to
high temperature due to a fire, deteriorations occur such as loss in
strength and elastic modulus, cracking and spalling of the concrete.
Therefore, it is important to understand risk of structural safety in
building structures by studying structural behaviors and rehabilitation
of fire damaged high strength concrete structures. This paper aims at
investigating rehabilitation effect on fire damaged high strength
concrete beams using experimental and analytical methods. In the
experiments, flexural specimens with high strength concrete are
exposed to high temperatures according to ISO 834 standard time
temperature curve. From four-point loading test, results show that
maximum loads of the rehabilitated beams are similar to or higher than
those of the non-fire damaged RC beam. In addition, structural
analyses are performed using ABAQUS 6.10-3 with same conditions
as experiments to provide accurate predictions on structural and
mechanical behaviors of rehabilitated RC beams. The parameters are
the fire cover thickness and strengths of repairing mortar. Analytical
results show good rehabilitation effects, when the results predicted
from the rehabilitated models are compared to structural behaviors of
the non-damaged RC beams. In this study, fire damaged high strength concrete beams are
rehabilitated using polymeric cement mortar. The predictions from the
finite element (FE) models show good agreements with the
experimental results and the modeling approaches can be used to
investigate applicability of various rehabilitation methods for further
study.
Abstract: In recent years, fire accidents have been steadily
increased and the amount of property damage caused by the accidents
has gradually raised. Damaging building structure, fire incidents bring
about not only such property damage but also strength degradation and
member deformation. As a result, the building structure undermines its
structural ability. Examining the degradation and the deformation is
very important because reusing the building is more economical than
reconstruction. Therefore, engineers need to investigate the strength
degradation and member deformation well, and make sure that they
apply right rehabilitation methods. This study aims at evaluating
deformation characteristics of fire damaged and rehabilitated normal
strength concrete beams through both experiments and finite element
analyses. For the experiments, control beams, fire damaged beams and
rehabilitated beams are tested to examine deformation characteristics.
Ten test beam specimens with compressive strength of 21MPa are
fabricated and main test variables are selected as cover thickness of
40mm and 50mm and fire exposure time of 1 hour or 2 hours. After
heating, fire damaged beams are air-recurred for 2 months and
rehabilitated beams are repaired with polymeric cement mortar after
being removed the fire damaged concrete cover. All beam specimens
are tested under four points loading. FE analyses are executed to
investigate the effects of main parameters applied to experimental
study. Test results show that both maximum load and stiffness of the
rehabilitated beams are higher than those of the fire damaged beams.
In addition, predicted structural behaviors from the analyses also show
good rehabilitation effect and the predicted load-deflection curves are
similar to the experimental results. For the further, the proposed
analytical method can be used to predict deformation characteristics of
fire damaged and rehabilitated concrete beams without suffering from
time and cost consuming of experimental process.
Abstract: The design philosophy of building structure has been
changing time to time. The reason for this is because of an increase of
human inertest, an improved building materials and technology that
will impact how we live, to speed up construction period and natural
effect which includes earthquake disasters and environmental effect.
One technique which takes in to account the above case is using a
prefabricable structural system. In which each and every structural
element is designed and prefabricated and assembled on a site so that
the construction speed is increased and the environmental impact is
also enhanced. This system has an immense advantage such as: reduce
construction cost, reusable, recyclable, speed up construction period
and less environmental effect. In this study, it is tried to present some
of the developed and evaluated structural elements of building
structures.