Abstract: Kurtbogazi Dam has gained special meaning for Ankara, Turkey for the last decade due to the rapid depletion of nearby resources of drinking water. In this study, the results of the analyses of Kurtbogazi Dam outlet water and the rivers flowing into the Kurtbogazi Dam were discussed for the period of last five years between 2008 and 2012. Some physical and chemical properties (pH, temperature, biochemical oxygen demand (BOD5), nitrate, phosphate and chlorine) of these water resources were evaluated. They were classified according to the Council Directive (75/440/EEC). Moreover, the properties of these surface waters were assessed to determine the quality of water for drinking and irrigation purposes using Piper, US Salinity Laboratory and Wilcox diagrams. The results showed that all the water resources are acceptable level as surface water except for Pazar Stream in terms of ortho-phosphate and BOD5 concentration for 2008.
Abstract: Industries produce millions of cubic meters of effluent
every year and the wastewater produced may be released into the
surrounding water bodies, treated on-site or at municipal treatment
plants. The determination of organic matter in the wastewater
generated is very important to avoid any negative effect on the
aquatic ecosystem. The scope of the present work is to assess the
physicochemical composition of the wastewater produced from one
of the brewery industry in South Africa. This is to estimate the
environmental impact of its discharge into the receiving water bodies
or the municipal treatment plant. The parameters monitored for the
quantitative analysis of brewery wastewater include biological
oxygen demand (BOD5), chemical oxygen demand (COD), total
suspended solids, volatile suspended solids, ammonia, total oxidized
nitrogen, nitrate, nitrite, phosphorus and alkalinity content. In
average, the COD concentration of the brewery effluent was 5340.97
mg/l with average pH values of 4.0 to 6.7. The BOD5 and the solids
content of the wastewater from the brewery industry were high. This
means that the effluent is very rich in organic content and its
discharge into the water bodies or the municipal treatment plant could
cause environmental pollution or damage the treatment plant. In
addition, there were variations in the wastewater composition
throughout the monitoring period. This might be as a result of
different activities that take place during the production process, as
well as the effects of peak period of beer production on the water
usage.
Abstract: Comparing other methods of waste water treatment,
constructed wetlands are one of the most fascinating practices
because being a natural process they are eco-friendly have low
construction and maintenance cost and have considerable capability
of wastewater treatment. The current research was focused mainly on
comparison of Ranunculus muricatus and Typha latifolia as wetland
plants for domestic wastewater treatment by designing and
constructing efficient pilot scale horizontal subsurface flow
mesocosms. Parameters like chemical oxygen demand, biological
oxygen demand, phosphates, sulphates, nitrites, nitrates, and
pathogenic indicator microbes were studied continuously with
successive treatments. Treatment efficiency of the system increases
with passage of time and with increase in temperature. Efficiency of
T. latifolia planted setups in open environment was fairly good for
parameters like COD and BOD5 which was showing reduction up to
82.5% for COD and 82.6% for BOD5 while DO was increased up to
125%. Efficiency of R. muricatus vegetated setup was also good but
lowers than that of T. latifolia planted showing 80.95% removal of
COD and BOD5. Ranunculus muricatus was found effective in
reducing bacterial count in wastewater. Both macrophytes were
found promising in wastewater treatment.
Abstract: The heavy metals pollution in water, sediments and fish of Lake Manzala affected form the disposal of wastewater, industrial and agricultural drainage water into the lake on the environmental situation. A pilot plant with an industrial discharge flow of 135L/h designed according to the activated sludge plant to simulate between the biological and chemical treatment with the addition of alum to the aeration tank with dosages of 100, 150, 200 and 250 mg/L. The industrial discharge had concentrations of Lead and BOD5 with an average range 1.22, 145mg/L respectively. That means the average Pb was high up to 25 times than the allowed permissible concentration. The optimization of the chemical-biological process using 200mg/L Alum dosage compared has improvement of Lead and BOD5 removal efficiency to 61.76% and 56% respectively.
Abstract: In this study, the effectiveness of an integrated aquatic
plants in phytogreen zone was studied and statistical analysis for the
promotional integrated phytogreen system approached was discussed.
It was found that's the effectiveness of using aquatic plant such as
Typha angustifolia sp., Lepironia articulata sp., Limnocharis flava
sp., Monochoria vaginalis sp., Pistia stratiotes sp., and Eichhornia
crassipes sp., in the conventional oxidation pond process in order to
comply the standard A according to Malaysia Environmental Quality
Act 1974 (Act 127); Environmental Quality (Sewage) Regulation
2009 for effluent discharge into inland water near the residential area
was successfully shown. It was concluded that the integrated
phtogreen system developed in this study has great potential for
refurbishment wastewater in conventional oxidation pond.
Abstract: Urbanization has been found to impact stormwater
runoff quantity and quality. A study catchment with mixed land use,
residential and industrial were investigated and the water quality
discharged from the catchment were sampled and tested for four
basic water quality parameters; BOD5, NH3-N, NO3-N and P. One
dry weather flow and several stormwater runoff were sampled.
Results were compared to the USEPA stormwater quality benchmark
values and the Interim National Water Quality Standards for
Malaysia (INWQS). The concentration of the parameters was found
to vary significantly between storms and the pollutant of concern was
found to be NO3-N.
Abstract: The Beshar River is one of the most important aquatic ecosystems in the upstream of the Karun watershed in south of Iran which is affected by point and non point pollutant sources . This study was done in order to evaluate the effects of pollutants activities on the water quality of the Beshar river and its aquatic ecosystems. This river is approximately 190 km in length and situated at the geographical positions of 51° 20´ to 51° 48´ E and 30° 18´ to 30° 52´ N it is one of the most important aquatic ecosystems of Kohkiloye and Boyerahmad province in south-west Iran. In this research project, five study stations were selected to examine water pollution in the Beshar River systems. Human activity is now one of the most important factors affecting on hydrology and water quality of the Beshar river. Humans use large amounts of resources to sustain various standards of living, although measures of sustainability are highly variable depending on how sustainability is defined. The Beshar river ecosystems are particularly sensitive and vulnerable to human activities. Therefore, to determine the impact of human activities on the Beshar River, the most important water quality parameters such as pH, dissolve oxygen (DO), Biological Oxygen Demand (BOD5), Total Dissolve Solids (TDS), Nitrates (NO3-N) and Phosphates (PO4) were estimated at the five stations. As the results show, the most important pollution index parameters such as BOD5, NO3 and PO4 increase and DO and pH decrease according to human activities (P
Abstract: The pollutant removal efficiency of the Intermittently
Decanted Extended Aeration (IDEA) wastewater treatment system at
Curtin University Sarawak Campus, and conventional activated
sludge wastewater treatment system at a local resort, Resort A, is
monitored. The influent and effluent characteristics are tested during
wet and dry weather conditions, and peak and off peak periods. For
the wastewater treatment systems at Curtin Sarawak and Resort A,
during dry weather and peak season, it was found that the BOD5
concentration in the influent is 121.7mg/L and 80.0mg/L
respectively, and in the effluent, 18.7mg/L and and 18.0mg/L
respectively. Analysis of the performance of the IDEA treatment
system showed that the operational costs can be minimized by 3%, by
decreasing the number of operating cycles. As for the treatment
system in Resort A, by utilizing a smaller capacity air blower, a
saving of 12% could be made in the operational costs.
Abstract: The Yasuj city stream named the Beshar supply
water for different usages such as aquaculture farms , drinking,
agricultural and industrial usages. Fish processing plants
,Agricultural farms, waste water of industrial zones and hospitals
waste water which they are generate by human activity produce a
considerable volume of effluent and when they are released in to the
stream they can effect on the water quality and down stream aquatic
systems. This study was conducted to evaluate the effects of outflow
effluent from different human activity and point and non point
pollution sources on the water quality and health of the Beshar
river next to Yasuj. Yasuj is the biggest and most important city in
the Kohkiloye and Boyerahmad province . The Beshar River is one
of the most important aquatic ecosystems in the upstream of the
Karun watershed in south of Iran which is affected by point and non
point pollutant sources . This study was done in order to evaluate the
effects of human activities on the water quality and health of the
Beshar river. This river is approximately 190 km in length and
situated at the geographical positions of 51° 20' to 51° 48' E and 30°
18' to 30° 52' N it is one of the most important aquatic ecosystems of
Kohkiloye and Boyerahmad province in south-west Iran. In this
research project, five study stations were selected to examine water
pollution in the Beshar River systems. Human activity is now one of
the most important factors affecting on hydrology and water quality
of the Beshar river. Humans use large amounts of resources to sustain
various standards of living, although measures of sustainability are
highly variable depending on how sustainability is defined. The
Beshar river ecosystems are particularly sensitive and vulnerable to
human activities. The water samples were analyzed, then some
important water quality parameters such as pH, dissolve oxygen
(DO), Biochemical Oxygen Demand (BOD5), Chemical Oxygen
Demand (COD), Total Suspended Solids (TDS),Turbidity,
Temperature, Nitrates (NO3) and Phosphates (PO4) were estimated
at the two stations. The results show a downward trend in the water
quality at the down stream of the city. The amounts of
BOD5,COD,TSS,T,Turbidity, NO3 and PO4 in the down stream
stations were considerably more than the station 1. By contrast the
amounts of DO in the down stream stations were less than to the
station 1. However when effluent discharge consequence of human
activities are released into the Beshar river near the city, the quality
of river are decreases and the environmental problems of the river
during the next years are predicted to rise.
Abstract: The feasibility of employing solar radiation for
enhanced Fenton process in degradation of combined chlorpyrifos,
cypermethrin and chlorothalonil pesticides was examined. The effect
of various operating conditions of the process on biodegradability
improvement and mineralization of the pesticides were also
evaluated. The optimum operating conditions for treatment of
aqueous solution containing 100, 50 and 250 mg L-1 chlorpyrifos
cypermethrin and chlorothalonil, respectively were observed to be
H2O2/COD molar ratio 2, H2O2/Fe2+ molar ratio 25 and pH 3. Under
the optimum operating conditions, complete degradation of the
pesticides occurred in 1 min. Biodegradability (BOD5/COD)
increased from zero to 0.36 in 60 min, and COD and TOC removal
were 74.19 and 58.32%, respectively in 60 min. Due to
mineralization of organic carbon, decrease in ammonia-nitrogen from
22 to 4.3 mg L-1 and increase in nitrate from 0.7 to 18.1 mg L-1 in
60 min were recorded. The study indicated that solar photo-Fenton
process can be used for pretreatment of chlorpyrifos, cypermethrin
and chlorothalonil pesticides in aqueous solution for further
biological treatment.
Abstract: The Beshar River is one aquatic ecosystem, which is
located next to the city of Yasuj in southern Iran. The Beshar river
has been contaminated by industrial factories such as effluent of
sugar factory, agricultural and other activities in this region such as,
Imam Sajjad hospital, drainage from agricultural farms, Yasuj urban
surface runoff and effluent of wastewater treatment plants ,specially
Yasuj waste water treatment plant. In order to evaluate the effects of
these pollutants on the quality of the Beshar river, five monitoring
stations were selected along its course. The first station is located
upstream of Yasuj near the Dehnow village; stations 2 to 4 are
located east, south and west of city; and the 5th station is located
downstream of Yasuj. Several water quality parameters were
sampled. These include pH, dissolved oxygen, biological oxygen
demand (BOD), temperature, conductivity, turbidity, total dissolved
solids and discharge or flow measurements. Water samples from the
five stations were collected and analyzed to determine the following
physicochemical parameters: EC, pH, T.D.S, T.H, No2, DO, BOD5,
COD during 2008 to 2010. The study shows that the BOD5 value of
station 1 is at a minimum (1.7 ppm) and increases downstream from
stations 2 to 4 to a maximum (11.6 ppm), and then decreases at
station 5. The DO values of station 1 is a maximum (8.45 ppm),
decreases downstream to stations 2 - 4 which are at a minimum (3.1
ppm), before increasing at station 5. The amount of BOD and TDS
are highest at the 4th station and the amount of DO is lowest at this
station, marking the 4th station as more highly polluted than the
other stations .This study shows average amount of the water quality
parameters in first year of sampling (2008) have had a better quality
relation to third year in 2010 because of recent drought in this region
and pollutant increasing .As the Beshar river path after 5th station
goes through the mountain area with more slope and flow velocity
,so the physicochemical parameters improve at the 5th station due to
pollutant degradation and dilution. Finally the point and nonpoint
pollutant sources of Beshar river were determined and compared to
the monitoring results.
Abstract: The Beshar River is one aquatic ecosystem,which is
affected by pollutants. This study was conducted to evaluate the
effects of human activities on the water quality of the Beshar river.
This river is approximately 190 km in length and situated at the
geographical positions of 51° 20' to 51° 48' E and 30° 18' to 30° 52'
N it is one of the most important aquatic ecosystems of Kohkiloye
and Boyerahmad province next to the city of Yasuj in southern Iran.
The Beshar river has been contaminated by industrial, agricultural
and other activities in this region such as factories, hospitals,
agricultural farms, urban surface runoff and effluent of wastewater
treatment plants. In order to evaluate the effects of these pollutants
on the quality of the Beshar river, five monitoring stations were
selected along its course. The first station is located upstream of
Yasuj near the Dehnow village; stations 2 to 4 are located east, south
and west of city; and the 5th station is located downstream of Yasuj.
Several water quality parameters were sampled. These include pH,
dissolved oxygen, biological oxygen demand (BOD), temperature,
conductivity, turbidity, total dissolved solids and discharge or flow
measurements. Water samples from the five stations were collected
and analysed to determine the following physicochemical
parameters: EC, pH, T.D.S, T.H, No2, DO, BOD5, COD during 2008
to 2009. The study shows that the BOD5 value of station 1 is at a
minimum (1.5 ppm) and increases downstream from stations 2 to 4 to
a maximum (7.2 ppm), and then decreases at station 5. The DO
values of station 1 is a maximum (9.55 ppm), decreases downstream
to stations 2 - 4 which are at a minimum (3.4 ppm), before increasing
at station 5. The amount of BOD and TDS are highest at the 4th
station and the amount of DO is lowest at this station, marking the
4th station as more highly polluted than the other stations. The
physicochemical parameters improve at the 5th station due to
pollutant degradation and dilution. Finally the point and nonpoint
pollutant sources of Beshar river were determined and compared to
the monitoring results.
Abstract: An experimental study of anaerobic treatment was performed by hybrid upflow anaerobic sludge blanket (HUASB) reactor to treat produced water (PW) of an onshore crude oil terminal (COD: 1597 mg/L, NH3-N: 14.7 mg/L, phenol: 13.8 mg/L, BOD5: 862 mg/L, sodium: 6240 mg/L and chloride 9530 mg/L). The produced water with high salinity and other toxic substances will inhibit the methanogens performance if there is no adaptation on biomass before anaerobic digestion. COD removal from produced water was investigated at five different dilutions of produced water and tap water (TW) without any nutrient addition and pre-treatment. The dilution ratios were 1PW:4TW, 2PW:3TW, 3PW:2TW, 4PW:1TW and 5PW:0TW. The reactor was evaluated at mesophilic operating condition (35 ± 2 °C) at 5 days of HRT for 250 days continuous feed. The average COD removals for 1PW:4TW, 2PW:3TW, 3PW:2TW, 4PW:1TW and 5PW:0TW were found to be approximately 76.1%, 73.8%, 70.3%, 46.3% and 61.82% respectively, with final average effluent COD of 123.7 mg/L, 240 mg/L, 294 mg/L, 589 mg/L and 738 mg/L, respectively.
Abstract: Urban non-point source (NPS) pollution for a
residential catchment in Miri, Sarawak was investigated for two storm events in 2011. Runoff from two storm events were sampled and tested for water quality parameters including TSS, BOD5, COD,
NH3-N, NO3-N, NO2-N, P and Pb. Concentration of the water quality
parameters was found to vary significantly between storms and the pollutant of concern was found to be NO3-N, TSS, COD and Pb. Results were compared to the Interim National Water Quality
Standards for Malaysia (INWQS),and the stormwater runoff from the
study can be classified as polluted, exceeding class III water quality,
especially in terms of TSS, COD, and NH3-N with maximum EMCs
of 158, 135, and 2.17 mg/L, respectively.