Abstract: This paper presented a novel combined cycle of air separation and natural gas liquefaction. The idea is that natural gas can be liquefied, meanwhile gaseous or liquid nitrogen and oxygen are produced in one combined cryogenic system. Cycle simulation and exergy analysis were performed to evaluate the process and thereby reveal the influence of the crucial parameter, i.e., flow rate ratio through two stages expanders β on heat transfer temperature difference, its distribution and consequent exergy loss. Composite curves for the combined hot streams (feeding natural gas and recycled nitrogen) and the cold stream showed the degree of optimization available in this process if appropriate β was designed. The results indicated that increasing β reduces temperature difference and exergy loss in heat exchange process. However, the maximum limit value of β should be confined in terms of minimum temperature difference proposed in heat exchanger design standard and heat exchanger size. The optimal βopt under different operation conditions corresponding to the required minimum temperature differences was investigated.
Abstract: This study presents the improvement of thermal
performance of heat pipe using copper nanofluid with aqueous
solution of n-Butanol. The nanofluids kept in the suspension of
conventional fluids have the potential of superior heat transfer
capability than the conventional fluids due to their improved thermal
conductivity. In this work, the copper nanofluid which has a 40 nm
size with a concentration of 100 mg/lit is kept in the suspension of
the de-ionized (DI) water and an aqueous solution of n-Butanol and
these fluids are used as a working medium in the heat pipe. The study
discusses about the effect of heat pipe inclination, type of working
fluid and heat input on the thermal efficiency and thermal resistance.
The experimental results are evaluated in terms of its performance
metrics and are compared with that of DI water.
Abstract: To evaluate genetic variation of wheat (Triticum aestivum) affected by heat and drought stress on eight Australian wheat genotypes that are parents of Doubled Haploid (HD) mapping populations at the vegetative stage, the water stress experiment was conducted at 65% field capacity in growth room. Heat stress experiment was conducted in the research field under irrigation over summer. Result show that water stress decreased dry shoot weight and RWC but increased osmolarity and means of Fv/Fm values in all varieties except for Krichauff. Krichauff and Kukri had the maximum RWC under drought stress. Trident variety was shown maximum WUE, osmolarity (610 mM/Kg), dry mater, quantum yield and Fv/Fm 0.815 under water stress condition. However, the recovery of quantum yield was apparent between 4 to 7 days after stress in all varieties. Nevertheless, increase in water stress after that lead to strong decrease in quantum yield. There was a genetic variation for leaf pigments content among varieties under heat stress. Heat stress decreased significantly the total chlorophyll content that measured by SPAD. Krichauff had maximum value of Anthocyanin content (2.978 A/g FW), chlorophyll a+b (2.001 mg/g FW) and chlorophyll a (1.502 mg/g FW). Maximum value of chlorophyll b (0.515 mg/g FW) and Carotenoids (0.234 mg/g FW) content belonged to Kukri. The quantum yield of all varieties decreased significantly, when the weather temperature increased from 28 ÔùªC to 36 ÔùªC during the 6 days. However, the recovery of quantum yield was apparent after 8th day in all varieties. The maximum decrease and recovery in quantum yield was observed in Krichauff. Drought and heat tolerant and moderately tolerant wheat genotypes were included Trident, Krichauff, Kukri and RAC875. Molineux, Berkut and Excalibur were clustered into most sensitive and moderately sensitive genotypes. Finally, the results show that there was a significantly genetic variation among the eight varieties that were studied under heat and water stress.
Abstract: In this paper, the feasibility study of using a hybrid
system of ground heat exchangers (GHE) and direct evaporative
cooling system in arid weather condition has been performed. The
model is applied for Yazd and Kerman, two cities with arid weather
condition in Iran. The system composed of three sections: Ground-
Coupled-Circuit (GCC), Direct Evaporative Cooler (DEC) and
Cooling Coil Unite (CCU). The GCC provides the necessary precooling
for DEC. The GCC includes four vertical GHE which are
designed in series configuration. Simulation results show that
hybridization of GCC and DEC could provide comfort condition
whereas DEC alone did not. Based on the results the cooling
effectiveness of a hybrid system is more than unity. Thus, this novel
hybrid system could decrease the air temperature below the ambient
wet-bulb temperature. This environmentally clean and energy
efficient system can be considered as an alternative to the mechanical
vapor compression systems.
Abstract: Ventilation is a fundamental requirement for
occupant health and indoor air quality in buildings. Natural
ventilation can be used as a design strategy in free-running
buildings to:
• Renew indoor air with fresh outside air and lower room
temperatures at times when the outdoor air is cooler.
• Promote air flow to cool down the building structure
(structural cooling).
• Promote occupant physiological cooling processes
(comfort cooling).
This paper focuses on ways in which ventilation can
provide the mechanism for heat dissipation and cooling of the
building structure..It also discusses use of ventilation as a
means of increasing air movement to improve comfort when
indoor air temperatures are too high. The main influencing
factors and design considerations and quantitative guidelines
to help meet the design objectives are also discussed.
Abstract: The aim of this study is to develop a cost-effective WBGT heat stress monitor which provides precise heat stress measurement. The proposed device employs SHT15 and DS18B20 as a temperature and humidity sensors, respectively, incorporating with ATmega328 microcontroller. The developed heat stress monitor was calibrated and adjusted to that of the standard temperature and humidity sensors in the laboratory. The results of this study illustrated that the mean percentage error and the standard deviation from the measurement of the globe temperature was 2.33 and 2.71 respectively, while 0.94 and 1.02 were those of the dry bulb temperature, 0.79 and 0.48 were of the wet bulb temperature, and 4.46 and 1.60 were of the relative humidity sensor. This device is relatively low-cost and the measurement error is acceptable.
Abstract: To simulate expected climate change, we implemented a two-factor (temperature and soil moisture) field design in a forest in Ontario, Canada. To manipulate moisture input, we erected rain-exclusion structures. Under each structure, plots were watered with one of three treatments and thermally controlled with three heat treatments to simulate changes in air temperature and rainfall based on the climate model (GCM) predictions for the study area. Environmental conditions (including untreated controls) were monitored tracking air temperature, soil temperature, soil moisture, and photosynthetically active radiation. We measured rainfall and relative humidity at the site outside the rain-exclusion structures. Analyses of environmental conditions demonstrates that the temperature manipulation was most effective at maintaining target temperature during the early part of the growing season, but it was more difficult to keep the warmest treatment at 5º C above ambient by late summer. Target moisture regimes were generally achieved however incoming solar radiation was slightly attenuated by the structures.
Abstract: Three dimensional simulations in tube in tube heat
exchangers are investigated numerically in this study. In these
simulations forced convective heat transfer and laminar flow of
single-phase water are considered. In order to measure heat transfer
parameters in these heat exchangers, FLUENT CFD Solver is used in
this numerical method. For the purpose of creating geometry and
exert boundary and initial conditions in the present model, finite
volume method in Computational Fluid Dynamics is used in this
study. In the present study, at each Z-location, variation of local
temperatures, heat flux and Nusselt number at the whole tube is
investigated in detail. Thereafter, averaged computational Nusselt
number in this model is calculated. In addition, conceivable pressure
drops have been obtained at each Z-location in this model. Then,
pressure drop values in the present model are explored. Finally, all
the numerical results for this kind of heat exchanger will be discussed
precisely.
Abstract: Cutting fluids, usually in the form of a liquid, are
applied to the chip formation zone in order to improve the cutting
conditions. Cutting fluid can be expensive and represents a biological
and environmental hazard that requires proper recycling and
disposal, thus adding to the cost of the machining operation. For
these reasons dry cutting or dry machining has become an
increasingly important approach; in dry machining no coolant or
lubricant is used. This paper discussed the effect of the dry cutting on
cutting force and tool life when machining aerospace materials
(Haynes 242) with using two different coated carbide cutting tools
(TiAlN and TiN/MT-TiCN/TiN). Response surface method (RSM)
was used to minimize the number of experiments. ParTiAlN Swarm
Optimisation (PSO) models were developed to optimize the
machining parameters (cutting speed, federate and axial depth) and
obtain the optimum cutting force and tool life. It observed that
carbide cutting tool coated with TiAlN performed better in dry
cutting compared with TiN/MT-TiCN/TiN. On other hand, TiAlN
performed more superior with using of 100 % water soluble coolant.
Due to the high temperature produced by aerospace materials, the
cutting tool still required lubricant to sustain the heat transfer from
the workpiece.
Abstract: We successfully developed and tested a new
separation layer solving problems with unmanageable deposits inside the boilers of Zluticka Heating Plant. The deposits are mainly created
by glass-forming melts. We plotted straw ash compositions in K2OCaO-
SiO2 phase diagram and illustrated that they are in the area of low-melting eutectic points. To prevent the melting of ash and the
formation of deposits, we modified ash compositions by injecting additives into biomass fuel, and thus effectively suppressed deposits in a burner.
Abstract: The optimal design of PI controller for Automatic Generation Control in two area is presented in this paper. The concept of Dual mode control is applied in the PI controller, such that the proportional mode is made active when the rate of change of the error is sufficiently larger than a specified limit otherwise switched to the integral mode. A digital simulation is used in conjunction with the Hooke-Jeeve’s optimization technique to determine the optimum parameters (individual gain of proportional and integral controller) of the PI controller. Integrated Square of the Error (ISE), Integrated Time multiplied by Absolute Error(ITAE) , and Integrated Absolute Error(IAE) performance indices are considered to measure the appropriateness of the designed controller. The proposed controller are tested for a two area single nonreheat thermal system considering the practical aspect of the problem such as Deadband and Generation Rate Constraint(GRC). Simulation results show that dual mode with optimized values of the gains improved the control performance than the commonly used Variable Structure .
Abstract: In this paper we use classical linear stability theory
to investigate the effects of uniform internal heat generation on the
onset of Marangoni convection in a horizontal layer of fluid heated
from below. We use a analytical technique to obtain the close form
analytical expression for the onset of Marangoni convection when
the lower boundary is conducting with free-slip condition. We show
that the effect of increasing the internal heat generation is always to
destabilize the layer.
Abstract: In contrast to existing methods which do not take into account multiconnectivity in a broad sense of this term, we develop mathematical models and highly effective combination (BIEM and FDM) numerical methods of calculation of stationary and cvazistationary temperature field of a profile part of a blade with convective cooling (from the point of view of realization on PC). The theoretical substantiation of these methods is proved by appropriate theorems. For it, converging quadrature processes have been developed and the estimations of errors in the terms of A.Ziqmound continuity modules have been received. For visualization of profiles are used: the method of the least squares with automatic conjecture, device spline, smooth replenishment and neural nets. Boundary conditions of heat exchange are determined from the solution of the corresponding integral equations and empirical relationships. The reliability of designed methods is proved by calculation and experimental investigations heat and hydraulic characteristics of the gas turbine 1st stage nozzle blade
Abstract: Steady state experiments have been conducted for
natural and mixed convection heat transfer, from five different sized
protruding discrete heat sources, placed at the bottom position on a
PCB and mounted on a vertical channel. The characteristic length (
Lh ) of heat sources vary from 0.005 to 0.011 m. The study has been
done for different range of Reynolds number and modified Grashof
number. From the experiment, the surface temperature distribution
and the Nusselt number of discrete heat sources have been obtained
and the effects of Reynold number and Richardson number on them
have been discussed. The objective is to find the rate of heat
dissipation from heat sources, by placing them at the bottom position
on a PCB and to compare both modes of cooling of heat sources.
Abstract: Turbulent heat transfer to fluid flow through channel with triangular ribs of different angles are presented in this paper. Ansys 14 ICEM and Ansys 14 Fluent are used for meshing process and solving Navier stokes equations respectively. In this investigation three angles of triangular ribs with the range of Reynolds number varied from 20000 to 60000 at constant surface temperature are considered. The results show that the Nusselt number increases with the increase of Reynolds number for all cases at constant surface temperature. According to the profile of local Nusselt number on ribs walled of channel, the peak is at the midpoint between the two ribs. The maximum value of average Nusselt number is obtained for triangular ribs of angel 60°and at Reynolds number of 60000 compared to the Nusselt number for the ribs of angel 90° and 45° and at same Reynolds number. The recirculation regions generated by the ribs corresponding to the velocity streamline show the largest recirculation region at triangular ribs of angle 60° which also provides the highest enhancement of heat transfer.
Abstract: There are extensive applications of lithium
bromide-water absorption chillers in industry, but the heat exchangers
corrosion and refrigerating capacity loss are very difficult to be solved.
In this paper, an experiment was conducted by using plastic heat
transfer tubes instead of copper tubes. As an example, for a lithium
bromide-water absorption chiller of refrigerating capacity of 35kW,
the correlative performance of the lithium bromide-water absorption
chiller using plastic heat transfer tubes was compared with the
traditional lithium bromide-water absorption chiller. And then the
following three aspects, i.e., heat transfer area, pipe resistance, and
safety strength, are analyzed. The results show that plastic heat
transfer tubes can be used on lithium bromide-water absorption
chillers, and its prospect is very optimistic.
Abstract: Unsteady natural convection and heat transfer in a square cavity partially filled with porous media using a thermal
non-equilibrium model is studied in this paper. The left vertical wall is
maintained at a constant hot temperature Th and the right vertical wall
is maintained at a constant cold temperature Tc, while the horizontal
walls are adiabatic. The governing equations are obtained by applying
the Darcy model and Boussinesq approximation. COMSOL’s finite
element method is used to solve the non-dimensional governing
equations together with specified boundary conditions. The governing
parameters of this study are the Rayleigh number (Ra = 10^5, and Ra = 10^6 ), Darcy namber (Da = 10^−2, and Da = 10^−3),
the modified thermal conductivity ratio (10^−1 ≤ γ ≤ 10^4), the inter-phase heat transfer coefficien (10^−1 ≤ H ≤ 10^3) and the
time dependent (0.001 ≤ τ ≤ 0.2). The results presented for
values of the governing parameters in terms of streamlines in both
fluid/porous-layer, isotherms of fluid in fluid/porous-layer, isotherms
of solid in porous layer, and average Nusselt number.
Abstract: In order to obtain an accurate result of the heat transfer
of the rib in the internal cooling Rectangular channel, using separation
of variables, analytical solutions of three dimensional steady-state heat
conduction in rectangular ribs are given by solving three dimensional
steady-state function of the rectangular ribs. Therefore, we can get
solution of three dimensional temperature field in the rib. Based on the
solution, we can get how the Bi number affected on heat transfer.
Furthermore, comparisons of the analytical and numerical results
indicate agreement on temperature field in the rib.
Abstract: In this paper, the optimum weight and cost of a laminated composite plate is seeked, while it undergoes the heaviest load prior to a complete failure. Various failure criteria are defined for such structures in the literature. In this work, the Tsai-Hill theory is used as the failure criterion. The theory of analysis was based on the Classical Lamination Theory (CLT). A newly type of Genetic Algorithm (GA) as an optimization technique with a direct use of real variables was employed. Yet, since the optimization via GAs is a long process, and the major time is consumed through the analysis, Radial Basis Function Neural Networks (RBFNN) was employed in predicting the output from the analysis. Thus, the process of optimization will be carried out through a hybrid neuro-GA environment, and the procedure will be carried out until a predicted optimum solution is achieved.
Abstract: The paper deals with determination of electromagnetic
and temperature field distribution of induction heating system used
for pipe brazing. The problem is considered as coupled – time
harmonic electromagnetic and transient thermal field. It has been
solved using finite element method. The detailed maps of
electromagnetic and thermal field distribution have been obtained.
The good understanding of the processes in the considered system
ensures possibilities for control, management and increasing the
efficiency of the welding process.