Abstract: In this paper we present an energy efficient match-line
(ML) sensing scheme for high-speed ternary content-addressable
memory (TCAM). The proposed scheme isolates the sensing unit of
the sense amplifier from the large and variable ML capacitance. It
employs feedback in the sense amplifier to successfully detect a
match while keeping the ML voltage swing low. This reduced voltage
swing results in large energy saving. Simulation performed using
130nm 1.2V CMOS logic shows at least 30% total energy saving in
our scheme compared to popular current race (CR) scheme for
similar search speed. In terms of speed, dynamic energy, peak power
consumption and transistor count our scheme also shows better
performance than mismatch-dependant (MD) power allocation
technique which also employs feedback in the sense amplifier.
Additionally, the implementation of our scheme is simpler than CR
or MD scheme because of absence of analog control voltage and
programmable delay circuit as have been used in those schemes.
Abstract: A techno-economic evaluation for efficient use of
energy in a large scale industrial plant of methanol is carried out.
This assessment is based on integration of a gas turbine with an
existing plant of methanol in which the outlet gas products of
exothermic reactor is expanded to power generation. Also, it is
decided that methanol production rate is constant through addition of
power generation system to the existing methanol plant. Having
incorporated a gas turbine with the existing plant, the economic
results showed total investment of MUSD 16.9, energy saving of 3.6
MUSD/yr with payback period of approximately 4.7 years.
Abstract: Ventilation is a fundamental requirement for
occupant health and indoor air quality in buildings. Natural
ventilation can be used as a design strategy in free-running
buildings to:
• Renew indoor air with fresh outside air and lower room
temperatures at times when the outdoor air is cooler.
• Promote air flow to cool down the building structure
(structural cooling).
• Promote occupant physiological cooling processes
(comfort cooling).
This paper focuses on ways in which ventilation can
provide the mechanism for heat dissipation and cooling of the
building structure..It also discusses use of ventilation as a
means of increasing air movement to improve comfort when
indoor air temperatures are too high. The main influencing
factors and design considerations and quantitative guidelines
to help meet the design objectives are also discussed.
Abstract: Artificial Bee Colony (ABC) algorithm is a relatively new swarm intelligence technique for clustering. It produces higher
quality clusters compared to other population-based algorithms but with poor energy efficiency, cluster quality consistency and typically slower in convergence speed. Inspired by energy saving foraging behavior of natural honey bees this paper presents a Quality and Quantity Aware Artificial Bee Colony (Q2ABC) algorithm to improve quality of cluster identification, energy efficiency and convergence speed of the original ABC. To evaluate the performance of Q2ABC algorithm, experiments were conducted on a suite of ten benchmark UCI datasets. The results demonstrate Q2ABC outperformed ABC and K-means algorithm in the quality of clusters delivered.
Abstract: Sensor networks are often deployed in unattended
environments, thus leaving these networks vulnerable to false data
injection attacks in which an adversary injects forged reports into the
network through compromised nodes, with the goal of deceiving the
base station or depleting the resources of forwarding nodes. Several
research solutions have been recently proposed to detect and drop such
forged reports during the forwarding process. Each design can provide
the equivalent resilience in terms of node compromising. However,
their energy consumption characteristics differ from each other. Thus,
employing only a single filtering scheme for a network is not a
recommendable strategy in terms of energy saving. It's very important
the threshold determination for message authentication to identify. We
propose the recursive contract net protocols which less energy level of
terminal node in wireless sensor network.
Abstract: The increasing demand for sufficient and clean
energy forces industrial and service companies to align their strategies towards efficient consumption. This trend refers also to the
residential building sector. There, large amounts of energy consumption are caused by house and facility heating. Many of the
operated hot water heating systems lack hydraulic balanced working
conditions for heat distribution and –transmission and lead to
inefficient heating. Through hydraulic balancing of heating systems,
significant energy savings for primary and secondary energy can be
achieved. This paper addresses the use of KNX-technology (Smart
Buildings) in residential buildings to ensure a dynamic adaption of
hydraulic system's performance, in order to increase the heating
system's efficiency. In this paper, the procedure of heating system
segmentation into hydraulically independent units (meshes) is
presented. Within these meshes, the heating valve are addressed and
controlled by a central facility server. Feasibility criteria towards
such drivers will be named. The dynamic hydraulic balance is
achieved by positioning these valves according to heating loads, that
are generated from the temperature settings in the corresponding
rooms. The energetic advantages of single room heating control
procedures, based on the application FacilityManager, is presented.
Abstract: Due to the high percentage of induction motors in industrial market, there exist a large opportunity for energy savings. Replacement of working induction motors with more efficient ones can be an important resource for energy savings. A calculation of energy savings and payback periods, as a result of such a replacement, based on nameplate motor efficiency or manufacture-s data can lead to large errors [1]. Efficiency of induction motors (IMs) can be extracted using some procedures that use the no-load test results. In the cases that we must estimate the efficiency on-line, some of these procedures can-t be efficient. In some cases the efficiency estimates using the rating values of the motor, but these procedures can have errors due to the different working condition of the motor. In this paper the efficiency of an IM estimated by using the genetic algorithm. The results are compared with the measured values of the torque and power. The results show smaller errors for this procedure compared with the conventional classical procedures, hence the cost of the equipments is reduced and on-line estimation of the efficiency can be made.
Abstract: The top-heavy demographic of low birth-rate and longer lifespan is a growing social problem, and one of its expected effects will be a shortage of young workers and a growing reliance on a workforce of middle-aged and older people. However, the environment of today's industrial workplace is not particularly suited to middle-aged and older workers, one notable problem being temperature control. Higher temperatures can cause health problems such as heat stroke, and the number of cases increases sharply in people over 65. Moreover, in conditions above 33°C, older people can develop circulatory system disorders, and also have a higher chance of suffering a fatal heart attack. We therefore propose a new method for controlling temperature in the indoor workplace. In this study two different verification experiments were conducted, with the proposed temperature control method being tested in cargo containers and conventional houses. The method's effectiveness was apparent in measurements of temperature and electricity consumption
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. Fueling the attention have been the possibilities of international agreements to reduce greenhouse gas emissions, electricity sector restructuring, high power reliability requirements for certain activities, and concern about easing transmission and distribution capacity bottlenecks and congestion. So it is necessary that impact of these kinds of generators on distribution feeder reconfiguration would be investigated. This paper presents an approach for distribution reconfiguration considering Distributed Generators (DGs). The objective function is summation of electrical power losses A Tabu search optimization is used to solve the optimal operation problem. The approach is tested on a real distribution feeder.
Abstract: One way for optimum loading of overdimensioning
conveyers is speed (capacity) decrement, with attention for
production capabilities and demands. At conveyers which drives with
three phase slip-ring induction motor, technically reasonable solution
for conveyer (driving motors) speed regulation is using constant
torque subsynchronous cascade with static semiconductor converter
and transformer for energy reversion to the power network. In the
paper is described mathematical model for parameter calculation of
two-motors 6 kV subsynchronous cascade. It is also demonstrated
that applying of this cascade gave several good properties, foremost
in electrical energy saving, also in improving of other energy
indexes, and finally that results in cost reduction of complete
electrical motor drive.
Abstract: Lighting upgrades involve relatively lower costs which
allow the benefits to be spread more widely than is possible with any
other energy efficiency measure. In order to popularize the adoption of
CFL in Taiwan, the authority proposes to implement a new energy efficient lamp comparative label system. The current study was
accordingly undertaken to investigate the factors affecting the performance and the deviation of actual and labeled performance of
commercially available integrated CFLs. In this paper, standard test
methods to determine the electrical and photometric performances of
CFL were developed based on CIE 84-1989 and CIE 60901-1987,
then 55 selected CFLs from market were tested. The results show that
with higher color temperature of CFLs lower efficacy are achieved. It
was noticed that the most packaging of CFL often lack the information of Color Rendering Index. Also, there was no correlation between
price and performance of the CFLs was indicated in this work. The results of this paper might help consumers to make more informed
CFL-purchasing decisions.
Abstract: Querying a data source and routing data towards sink
becomes a serious challenge in static wireless sensor networks if sink
and/or data source are mobile. Many a times the event to be observed
either moves or spreads across wide area making maintenance of
continuous path between source and sink a challenge. Also, sink can
move while query is being issued or data is on its way towards sink.
In this paper, we extend our already proposed Grid Based Data
Dissemination (GBDD) scheme which is a virtual grid based
topology management scheme restricting impact of movement of
sink(s) and event(s) to some specific cells of a grid. This obviates the
need for frequent path modifications and hence maintains continuous
flow of data while minimizing the network energy consumptions.
Simulation experiments show significant improvements in network
energy savings and average packet delay for a packet to reach at sink.
Abstract: In a world of climate change and limited fossil fuel resources, renewable energy sources are playing an increasingly important role. Due to industrializations and population growth our economy and technologies today largely depend upon natural resources, which are not replaceable. Approximately 90% of our energy consumption comes from fossil fuels (viz. coal, oil and natural gas). The irony is that these resources are depleting. Also, the huge consumption of fossil fuels has caused visible damage to the environment in various forms viz. global warming, acid rains etc.
Abstract: The benefits of rooftop greenery systems (such as
energy savings, reduction of greenhouse gas emission for mitigating
climate change and maintaining sustainable development, indoor
temperature control etc.) in buildings are well recognized, however
there remains very little research conducted for quantifying the
benefits in subtropical climates such as in Australia. This study
mainly focuses on measuring/determining temperature profile and air
conditioning energy savings by implementing rooftop greenery
systems in subtropical Central Queensland in Australia. An
experimental set-up was installed at Rockhampton campus of Central
Queensland University, where two standard shipping containers (6m
x 2.4m x 2.4m) were converted into small offices, one with green
roof and one without. These were used for temperature, humidity and
energy consumption data collection. The study found that an energy
savings of up to 11.70% and temperature difference of up to 4°C can
be achieved in March in subtropical Central Queensland climate in
Australia. It is expected that more energy can be saved in peak
summer days (December/February) as temperature difference
between green roof and non-green roof is higher in December-
February.
Abstract: In this paper, in order to investigate the effects of
photovoltaic system introduction to detached houses in Japan, two
kinds of works were done. Firstly, the hourly generation amount of a
4.2kW photovoltaic system were simulated in 46 cities to investigate
the potential of the system in different regions in Japan using a
simulation model of photovoltaic system. Secondly, based on the
simulated electricity generation amount, the energy saving, the
environmental and the economic effect of the photovoltaic system
were examined from hourly to annual timescales, based upon
calculations of typical electricity, heating, cooling and hot water
supply load profiles for Japanese dwellings. The above analysis was
carried out using a standard year-s hourly weather data for the
different city provided by the Expanded AMeDAS Weather Data
issued by AIJ (Architectural Institute of Japan).
Abstract: Energy consumption is an important design issue for
Mobile Subscriber Station (MSS) in the standard IEEE 802.16e.
Because mobility of MSS implies that energy saving becomes an
issue so that lifetime of MSS can be extended before re-charging.
Also, the mechanism in efficiently managing the limited energy is
becoming very significant since a MSS is generally energized by
battery. For these, sleep mode operation is recently specified in the
MAC (Medium Access Control) protocol. In order to reduce the
energy consumption, we focus on the sleep-mode and wake-mode of
the MAC layer, which are included in the IEEE 802.16 standards [1-
2].
Abstract: Passive systems were born with the purpose of the
greatest exploitation of solar energy in cold climates and high
altitudes. They spread themselves until the 80-s all over the world
without any attention to the specific climate and the summer
behavior; this caused the deactivation of the systems due to a series
of problems connected to the summer overheating, the complex
management and the rising of the dust.
Until today the European regulation limits only the winter
consumptions without any attention to the summer behavior but, the
recent European EN 15251 underlines the relevance of the indoor
comfort, and the necessity of the analytic studies validation by
monitoring case studies.
In the porpose paper we demonstrate that the solar wall is an
efficient system both from thermal comfort and energy saving point
of view and it is the most suitable for our temperate climates because
it can be used as a passive cooling sistem too. In particular the paper
present an experimental and numerical analisys carried out on a case
study with nine different solar passive systems in Ancona, Italy.
We carried out a detailed study of the lodging provided by the
solar wall by the monitoring and the evaluation of the indoor
conditions.
Analyzing the monitored data, on the base of recognized models
of comfort (ISO, ASHRAE, Givoni-s BBCC), is emerged that the
solar wall has an optimal behavior in the middle seasons. In winter
phase this passive system gives more advantages in terms of energy
consumptions than the other systems, because it gives greater heat
gain and therefore smaller consumptions. In summer, when outside
air temperature return in the mean seasonal value, the indoor comfort
is optimal thanks to an efficient transversal ventilation activated from
the same wall.
Abstract: As the data-driven economy is growing faster than
ever and the demand for energy is being spurred, we are facing
unprecedented challenges of improving energy efficiency in data
centers. Effectively maximizing energy efficiency or minimising the
cooling energy demand is becoming pervasive for data centers. This
paper investigates overall energy consumption and the energy
efficiency of cooling system for a data center in Finland as a case
study. The power, cooling and energy consumption characteristics
and operation condition of facilities are examined and analysed.
Potential energy and cooling saving opportunities are identified and
further suggestions for improving the performance of cooling system
are put forward. Results are presented as a comprehensive evaluation
of both the energy performance and good practices of energy
efficient cooling operations for the data center. Utilization of an
energy recovery concept for cooling system is proposed. The
conclusion we can draw is that even though the analysed data center
demonstrated relatively high energy efficiency, based on its power
usage effectiveness value, there is still a significant potential for
energy saving from its cooling systems.
Abstract: Sustainable energy usage has been recognized as one
of the important measure to increase the competitiveness of the
nation globally. Many strong emphases were given in the Ninth
Malaysia Plan (RMK9) to improve energy efficient especially to
government buildings. With this in view, a project to investigate the
potential of energy saving in selected building in Universiti Tun
Hussein Onn Malaysia (UTHM) was carried out. In this project, a
case study involving electric energy consumption of the academic
staff office building was conducted. The scope of the study include to
identify energy consumption in a selected building, to study energy
saving opportunities, to analyse cost investment in term of economic
and to identify users attitude with respect to energy usage. The
MS1525:2001, Malaysian Standard -Code of practice on energy
efficiency and use of renewable energy for non-residential buildings
was used as reference. Several energy efficient measures were
considered and their merits and priority were compared. Improving
human behavior can reduce energy consumption by 6% while
technical measure can reduce energy consumption by 44%. Two
economic analysis evaluation methods were applied; they are the
payback period method and net present value method.
Abstract: The objective of this paper is to present a research
study of the convectors that are used for heating or cooling of the
living room or industrial halls. The key points are experimental
measurement and comprehensive numerical simulation of the flow
coming throughout the part of the convector such as heat exchanger,
input from the fan etc.. From the obtained results, the components of
the convector are optimized in sense to increase thermal power
efficiency due to improvement of heat convection or reduction of air
drag friction. Both optimized aspects are leading to the more
effective service conditions and to energy saving. The significant part
of the convector research is a design of the unique measurement
laboratory and adopting measure techniques. The new laboratory
provides possibility to measure thermal power efficiency and other
relevant parameters under specific service conditions of the
convectors.