Abstract: The paper presents the brief information on particular results of experimental study focused to the problems of behavior of structural plated components made of fiber-cement-based materials and used in building constructions, exposed to atmospheric physical effects given by the weather changes in the summer period. Weather changes represented namely by temperature and rain cause also the changes of the temperature and moisture of the investigated structural components. This can affect their static behavior that means stresses and deformations, which have been monitored as the main outputs of tests performed. Experimental verification is based on the simulation of the influence of temperature and rain using the defined procedure of warming and water sprinkling with respect to the corresponding weather conditions during summer period in the South Moravian region at the Czech Republic, for which the application of these structural components is mainly planned. Two types of components have been tested: (i) glass-fiber-concrete panels used for building façades and (ii) fiber-cement slabs used mainly for claddings, but also as a part of floor structures or lost shuttering, and so on.
Abstract: This study describes analysis of tower grounding
resistance effected the back flashover voltage across insulator string
in a transmission system. This paper studies the 500 kV transmission
lines from Mae Moh, Lampang to Nong Chok, Bangkok, Thailand,
which is double circuit in the same steel tower with two overhead
ground wires. The factor of this study includes magnitude of
lightning stroke, and front time of lightning stroke. Steel tower uses
multistory tower model. The assumption of studies based on the
return stroke current ranged 1-200 kA, front time of lightning stroke
between 1 μs to 3 μs. The simulations study the effect of varying
tower grounding resistance that affect the lightning current.
Simulation results are analyzed lightning over voltage that causes
back flashover at insulator strings. This study helps to know causes
of problems of back flashover the transmission line system, and also
be as a guideline solving the problem for 500 kV transmission line
systems, as well.
Abstract: In this paper we present the information life cycle and analyze the importance of managing the corporate application portfolio across this life cycle. The approach presented here corresponds not just to the extension of the traditional information system development life cycle. This approach is based in the generic life cycle. In this paper it is proposed a model of an information system life cycle, supported in the assumption that a system has a limited life. But, this limited life may be extended. This model is also applied in several cases; being reported here two examples of the framework application in a construction enterprise and in a manufacturing enterprise.
Abstract: This paper focuses on the problem of a common linear copositive Lyapunov function(CLCLF) existence for discrete-time switched positive linear systems(SPLSs) with bounded time-varying delays. In particular, applying system matrices, a special class of matrices are constructed in an appropriate manner. Our results reveal that the existence of a common copositive Lyapunov function can be related to the Schur stability of such matrices. A simple example is provided to illustrate the implication of our results.
Abstract: When architecting an application, key nonfunctional requirements such as performance, scalability, availability and security, which influence the architecture of the system, are some times not adequately addressed. Performance of the application may not be looked at until there is a concern. There are several problems with this reactive approach. If the system does not meet its performance objectives, the application is unlikely to be accepted by the stakeholders. This paper suggests an approach for performance modeling for web based J2EE and .Net applications to address performance issues early in the development life cycle. It also includes a Performance Modeling Case Study, with Proof-of-Concept (PoC) and implementation details for .NET and J2EE platforms.
Abstract: In the present study, a procedure was developed to
determine the optimum reaction rate constants in generalized
Arrhenius form and optimized through the Nelder-Mead method. For
this purpose, a comprehensive mathematical model of a fixed bed
reactor for dehydrogenation of heavy paraffins over Pt–Sn/Al2O3
catalyst was developed. Utilizing appropriate kinetic rate expressions
for the main dehydrogenation reaction as well as side reactions and
catalyst deactivation, a detailed model for the radial flow reactor was
obtained. The reactor model composed of a set of partial differential
equations (PDE), ordinary differential equations (ODE) as well as
algebraic equations all of which were solved numerically to
determine variations in components- concentrations in term of mole
percents as a function of time and reactor radius. It was demonstrated
that most significant variations observed at the entrance of the bed
and the initial olefin production obtained was rather high. The
aforementioned method utilized a direct-search optimization
algorithm along with the numerical solution of the governing
differential equations. The usefulness and validity of the method was
demonstrated by comparing the predicted values of the kinetic
constants using the proposed method with a series of experimental
values reported in the literature for different systems.
Abstract: Guaranteeing the availability of the required parts at
the scheduled time represents a key logistical challenge. This is
especially important when several parts are required together. This
article describes a tool that supports the positioning in the area of
conflict between low stock costs and a high service level for a
consumer.
Abstract: Cryptographic algorithms play a crucial role in the
information society by providing protection from unauthorized
access to sensitive data. It is clear that information technology will
become increasingly pervasive, Hence we can expect the emergence
of ubiquitous or pervasive computing, ambient intelligence. These
new environments and applications will present new security
challenges, and there is no doubt that cryptographic algorithms and
protocols will form a part of the solution. The efficiency of a public
key cryptosystem is mainly measured in computational overheads,
key size and bandwidth. In particular the RSA algorithm is used in
many applications for providing the security. Although the security
of RSA is beyond doubt, the evolution in computing power has
caused a growth in the necessary key length. The fact that most chips
on smart cards can-t process key extending 1024 bit shows that there
is need for alternative. NTRU is such an alternative and it is a
collection of mathematical algorithm based on manipulating lists of
very small integers and polynomials. This allows NTRU to high
speeds with the use of minimal computing power. NTRU (Nth degree
Truncated Polynomial Ring Unit) is the first secure public key
cryptosystem not based on factorization or discrete logarithm
problem. This means that given sufficient computational resources
and time, an adversary, should not be able to break the key. The
multi-party communication and requirement of optimal resource
utilization necessitated the need for the present day demand of
applications that need security enforcement technique .and can be
enhanced with high-end computing. This has promoted us to develop
high-performance NTRU schemes using approaches such as the use
of high-end computing hardware. Peer-to-peer (P2P) or enterprise
grids are proven as one of the approaches for developing high-end
computing systems. By utilizing them one can improve the
performance of NTRU through parallel execution. In this paper we
propose and develop an application for NTRU using enterprise grid
middleware called Alchemi. An analysis and comparison of its
performance for various text files is presented.
Abstract: This paper evaluate the multilevel modulation for
different techniques such as amplitude shift keying (M-ASK), MASK,
differential phase shift keying (M-ASK-Bipolar), Quaternary
Amplitude Shift Keying (QASK) and Quaternary Polarization-ASK
(QPol-ASK) at a total bit rate of 107 Gbps. The aim is to find a costeffective
very high speed transport solution. Numerical investigation
was performed using Monte Carlo simulations. The obtained results
indicate that some modulation formats can be operated at 100Gbps
in optical communication systems with low implementation effort
and high spectral efficiency.
Abstract: In this study the regional stability of a rotor system which is supported on rolling bearings with radial clearance is studied. The rotor is assumed to be rigid. Due to radial clearance of bearings and dynamic configuration of system, each rolling elements of bearings has the possibility to be in contact with both of the races (under compression) or lose its contact. As a result, this change in dynamic of the system makes it to be known as switching system which is a type of Hybrid systems. In this investigation by adopting Multiple Lyapunov Function theorem and using Hamiltonian function as a candidate Lyapunov function, the stability of the system is studied. The purpose of this study is to inspect the regional stability of rotor-roller bearing and rotor-ball bearing systems.
Abstract: The wireless adhoc network is comprised of wireless
node which can move freely and are connected among themselves
without central infrastructure. Due to the limited transmission range
of wireless interfaces, in most cases communication has to be relayed
over intermediate nodes. Thus, in such multihop network each node
(also called router) is independent, self-reliant and capable to route
the messages over the dynamic network topology. Various protocols
are reported in this field and it is very difficult to decide the best one.
A key issue in deciding which type of routing protocol is best for
adhoc networks is the communication overhead incurred by the
protocol. In this paper STAR a table driven and DSR on demand
protocols based on IEEE 802.11 are analyzed for their performance
on different performance measuring metrics versus varying traffic
CBR load using QualNet 5.0.2 network simulator.
Abstract: Individually Network reconfiguration or Capacitor control
perform well in minimizing power loss and improving voltage
profile of the distribution system. But for heavy reactive power loads
network reconfiguration and for heavy active power loads capacitor
placement can not effectively reduce power loss and enhance
voltage profiles in the system. In this paper, an hybrid approach
that combine network reconfiguration and capacitor placement using
Harmony Search Algorithm (HSA) is proposed to minimize power
loss reduction and improve voltage profile. The proposed approach
is tested on standard IEEE 33 and 16 bus systems. Computational
results show that the proposed hybrid approach can minimize losses
more efficiently than Network reconfiguration or Capacitor control.
The results of proposed method are also compared with results
obtained by Simulated Annealing (SA). The proposed method has
outperformed in terms of the quality of solution compared to SA.
Abstract: This paper proposes a novel system for monitoring the
health of underground pipelines. Some of these pipelines transport
dangerous contents and any damage incurred might have catastrophic
consequences. However, most of these damage are unintentional and
usually a result of surrounding construction activities. In order to
prevent these potential damages, monitoring systems are
indispensable. This paper focuses on acoustically recognizing road
cutters since they prelude most construction activities in modern
cities. Acoustic recognition can be easily achieved by installing a
distributed computing sensor network along the pipelines and using
smart sensors to “listen" for potential threat; if there is a real threat,
raise some form of alarm. For efficient pipeline monitoring, a novel
monitoring approach is proposed. Principal Component Analysis
(PCA) was studied and applied. Eigenvalues were regarded as the
special signature that could characterize a sound sample, and were
thus used for the feature vector for sound recognition. The denoising
ability of PCA could make it robust to noise interference. One class
SVM was used for classifier. On-site experiment results show that the
proposed PCA and SVM based acoustic recognition system will be
very effective with a low tendency for raising false alarms.
Abstract: This paper describes the development of a control
system model using a graphical software tool. This control system is
part of an operator training simulator developed for the National
Training Center for Operators of Ixtapantongo (CNCAOI, acronym
according to its name in Spanish language) of the Mexico-s Federal
Commission of Electricity, CFE). The Department of Simulation of
the Electrical Research Institute (IIE) developed this simulator using
as reference the Unit I of the Combined Cycle Power Plant El Sauz,
located at the centre of Mexico. The first step in the project was the
developing of the Gas Turbine System and its control system
simulator. The Turbo Gas simulator was finished and delivered to
CNCAOI in March 2007 for commercial operation. This simulator is
a high-fidelity real time dynamic simulator built and tested for
accurate operation over the entire load range. The simulator was used
primarily for operator training although it has been used for
procedure development and evaluation of plant transients.
Abstract: This paper proposes a methodology for mitigating the occurrence of cascading failure in stressed power systems. The methodology is essentially based on predicting voltage instability in the power system using a voltage stability index and then devising a corrective action in order to increase the voltage stability margin. The paper starts with a brief description of the cascading failure mechanism which is probable root cause of severe blackouts. Then, the voltage instability indices are introduced in order to evaluate stability limit. The aim of the analysis is to assure that the coordination of protection, by adopting load shedding scheme, capable of enhancing performance of the system after the major location of instability is determined. Finally, the proposed method to generate instability prediction is introduced.
Abstract: Noise has adverse effect on human health and
comfort. Noise not only cause hearing impairment, but it also acts as
a causal factor for stress and raising systolic pressure. Additionally it
can be a causal factor in work accidents, both by marking hazards
and warning signals and by impeding concentration. Industry
workers also suffer psychological and physical stress as well as
hearing loss due to industrial noise. This paper proposes an approach
to enable engineers to point out quantitatively the noisiest source for
modification, while multiple machines are operating simultaneously.
The model with the point source and spherical radiation in a free field
was adopted to formulate the problem. The procedure works very
well in ideal cases (point source and free field). However, most of the
industrial noise problems are complicated by the fact that the noise is
confined in a room. Reflections from the walls, floor, ceiling, and
equipment in a room create a reverberant sound field that alters the
sound wave characteristics from those for the free field. So the model
was validated for relatively low absorption room at NIT Kurukshetra
Central Workshop. The results of validation pointed out that the
estimated sound power of noise sources under simultaneous
conditions were on lower side, within the error limits 3.56 - 6.35 %.
Thus suggesting the use of this methodology for practical
implementation in industry. To demonstrate the application of the
above analytical procedure for estimating the sound power of noise
sources under simultaneous operating conditions, a manufacturing
facility (Railway Workshop at Yamunanagar, India) having five
sound sources (machines) on its workshop floor is considered in this
study. The findings of the case study had identified the two most
effective candidates (noise sources) for noise control in the Railway
Workshop Yamunanagar, India. The study suggests that the
modification in the design and/or replacement of these two identified
noisiest sources (machine) would be necessary so as to achieve an
effective reduction in noise levels. Further, the estimated data allows
engineers to better understand the noise situations of the workplace
and to revise the map when changes occur in noise level due to a
workplace re-layout.
Abstract: Flight management system (FMS) is a specialized
computer system that automates a wide variety of in-flight tasks,
reducing the workload on the flight crew to the point that modern
aircraft no longer carry flight engineers or navigators. The primary
function of FMS is to perform the in-flight management of the flight
plan using various sensors (such as GPS and INS often backed up by
radio navigation) to determine the aircraft's position. From the
cockpit FMS is normally controlled through a Control Display Unit
(CDU) which incorporates a small screen and keyboard or touch
screen. This paper investigates the performance of GPS/ INS
integration techniques in which the data fusion process is done using
Kalman filtering. This will include the importance of sensors
calibration as well as the alignment of the strap down inertial
navigation system. The limitations of the inertial navigation systems
are investigated in order to understand why INS sometimes is
integrated with other navigation aids and not just operating in standalone
mode. Finally, both the loosely coupled and tightly coupled
configurations are analyzed for several types of situations and
operational conditions.
Abstract: This paper discusses a design of nonlinear observer by
a formal linearization method using an application of Chebyshev Interpolation
in order to facilitate processes for synthesizing a nonlinear
observer and to improve the precision of linearization.
A dynamic nonlinear system is linearized with respect to a linearization
function, and a measurement equation is transformed into
an augmented linear one by the formal linearization method which is
based on Chebyshev interpolation. To the linearized system, a linear
estimation theory is applied and a nonlinear observer is derived. To
show effectiveness of the observer design, numerical experiments
are illustrated and they indicate that the design shows remarkable
performances for nonlinear systems.
Abstract: The data is available in abundance in any business
organization. It includes the records for finance, maintenance,
inventory, progress reports etc. As the time progresses, the data keep
on accumulating and the challenge is to extract the information from
this data bank. Knowledge discovery from these large and complex
databases is the key problem of this era. Data mining and machine
learning techniques are needed which can scale to the size of the
problems and can be customized to the application of business. For
the development of accurate and required information for particular
problem, business analyst needs to develop multidimensional models
which give the reliable information so that they can take right
decision for particular problem. If the multidimensional model does
not possess the advance features, the accuracy cannot be expected.
The present work involves the development of a Multidimensional
data model incorporating advance features. The criterion of
computation is based on the data precision and to include slowly
change time dimension. The final results are displayed in graphical
form.
Abstract: Power consumption is rapidly increased in data centers
because the number of data center is increased and more the scale of
data center become larger. Therefore, it is one of key research items to
reduce power consumption in data center. The peak power of a typical
server is around 250 watts. When a server is idle, it continues to use
around 60% of the power consumed when in use, though vendors are
putting effort into reducing this “idle" power load. Servers tend to
work at only around a 5% to 20% utilization rate, partly because of
response time concerns. An average of 10% of servers in their data
centers was unused. In those reason, we propose dynamic power
management system to reduce power consumption in green data
center. Experiment result shows that about 55% power consumption is
reduced at idle time.