Abstract: Experimental investigations were made on the instability of supercritical kerosene flowing in active cooling channels. Two approaches were used to control the pressure in the channel. One is the back-pressure valve while the other is the venturi. In both conditions, a kind of low-frequency oscillation of pressure and temperature is observed. And the oscillation periods are calculated. By comparison with the flow time, it is concluded that the instability occurred in active cooling channels is probably one kind of density wave instability. And its period has no relationship with the cooling channel geometry, nor the pressure, but only depends on the flow time of kerosene in active cooling channels. When the mass flow rate, density and pressure drop couple with each other, the density wave instability will appear.
Abstract: Porcelain specimens were fired at 6C/min to 1250C (dwell time 0.5-3h) and cooled at 6C/min to room temperature. Additionally, three different slower firing/cooling cycles were tried. Sintering profile and effects on MOR, crystalline phase content and morphology were investigated using dilatometry, 4-point bending strength, XRD and FEG-SEM respectively. Industrial-sized specimens prepared using the promising cycle were tested basing on the ANSI standards. Increasing dwell time from 1h to 3h at peak temperature of 1250C resulted in neither a significant effect on the quartz and mullite content nor MOR. Reducing the firing/cooling rate to below 6C/min, for peak temperature of 1250C (dwell time of 1h) does not result in improvement of strength of porcelain. The industrial sized specimen exhibited flashover voltages of 20.3kV (dry) and 9.3kV (wet) respectively, transverse strength of 12.5kN and bulk density of 2.27g/cm3, which are satisfactory. There was however dye penetration during porosity test. KeywordsDwell time, Microstructure, Porcelain, Strength.
Abstract: In this paper, the steady-state temperature of a sample 500 KW two rotor one stator Non-slotted axial flux permanent magnet motor is calculated using the finite element simulator software package. Due to the high temperature in various parts of the machine, especially at stator winding, a cooling system is designed for the motor and the temperature is recalculated. The results show that the temperature obtained for the parts is within the permissible range.
Abstract: Auckland has a temperate climate with comfortable
warm, dry summers and mild, wet winters. An Auckland school
normally does not need air conditioning for cooling during the
summer and only need heating during the winter. The space hating
energy is the major portion of winter school energy consumption and
the winter energy consumption is major portion of annual school
energy consumption. School building thermal design should focus
on the winter thermal performance for reducing the space heating
energy. A number of Auckland schools- design data and energy
consumption data are used for this study. This pilot study
investigates the relationships between their energy consumption data
and school building design data to improve future school design for
energy efficiency.
Abstract: Alumina matrix composites with addition of hexagonal boron nitride (hBN), acting as solid lubricant, were produced. Main purpose of solid lubricants is to dispose the necessity of using cooling lubricants in machining process. Hot pressing was used as a consolidating process for Al2O3-x%wt.hBN (x=1/ 2,5/ 5 /7,5 /10) composites. Properties of sinters such as relative density, hardness, Young-s modulus and fracture toughness were examined. Obtained samples characterize by high relative density. Hardness and fracture toughness values allow the use of alumina – hBN composites for machining steels even in hardened condition. However it was observed that high weight content of hBN can negatively influence the mechanical properties of composites.
Abstract: Manufacturing components of fiber-reinforced
thermoplastics requires three steps: heating the matrix, forming and
consolidation of the composite and terminal cooling the matrix. For
the heating process a pre-determined temperature distribution through
the layers and the thickness of the pre-consolidated sheets is
recommended to enable forming mechanism. Thus, a design for the
heating process for forming composites with thermoplastic matrices
is necessary. To obtain a constant temperature through thickness and
width of the sheet, the heating process was analyzed by the help of
the finite element method. The simulation models were validated by
experiments with resistance thermometers as well as with an infrared
camera. Based on the finite element simulation, heating methods for
infrared radiators have been developed. Using the numeric
simulation many iteration loops are required to determine the process
parameters. Hence, the initiation of a model for calculating relevant
process parameters started applying regression functions.
Abstract: This paper presents the experimental as well as the
simulated performance studies on the transcritical CO2 heat pumps
for simultaneous water cooling and heating; effects of water mass
flow rates and water inlet temperatures of both evaporator and gas
cooler on the cooling and heating capacities, system COP and water
outlets temperatures are investigated. Study shows that both the
water mass flow rate and inlet temperature have significant effect on
system performances. Test results show that the effect of evaporator
water mass flow rate on the system performances and water outlet
temperatures is more pronounced (COP increases 0.6 for 1 kg/min)
compared to the gas cooler water mass flow rate (COP increases 0.4
for 1 kg/min) and the effect of gas cooler water inlet temperature is
more significant (COP decreases 0.48 for given ranges) compared to
the evaporator water inlet temperature (COP increases 0.43 for given
ranges). Comparisons of experimental values with simulated results
show the maximum deviation of 5% for cooling capacity, 10% for
heating capacity, 16% for system COP. This study offers useful
guidelines for selecting appropriate water mass flow rate to obtain
required system performance.
Abstract: Vibration characteristics of subcooled flow boiling on
thin and long structures such as a heating rod were recently
investigated by the author. The results show that the intensity of the
subcooled boiling-induced vibration (SBIV) was influenced strongly
by the conditions of the subcooling temperature, linear power density
and flow velocity. Implosive bubble formation and collapse are the
main nature of subcooled boiling, and their behaviors are the only
sources to originate from SBIV. Therefore, in order to explain the
phenomenon of SBIV, it is essential to obtain reliable information
about bubble behavior in subcooled boiling conditions. This was
investigated at different conditions of coolant subcooling
temperatures of 25 to 75°C, coolant flow velocities of 0.16 to
0.53m/s, and linear power densities of 100 to 600 W/cm. High speed
photography at 13,500 frames per second was performed at these
conditions. The results show that even at the highest subcooling
condition, the absolute majority of bubbles collapse very close to the
surface after detaching from the heating surface. Based on these
observations, a simple model of surface tension and momentum
change is introduced to offer a rough quantitative estimate of the
force exerted on the heating surface during the bubble ebullition. The
formation of a typical bubble in subcooled boiling is predicted to
exert an excitation force in the order of 10-4 N.
Abstract: Axial Flux Permanent Magnet (AFPM) Machines require effective cooling due to their high power density. The detrimental effects of overheating such as degradation of the insulation materials, magnets demagnetization, and increase of Joule losses are well known. This paper describes the CFD simulations performed on a test rig model of an air cooled Axial Flux Permanent Magnet (AFPM) generator built at Durham University to identify the temperatures and heat transfer coefficient on the stator. The Reynolds Averaged Navier-Stokes and the Energy equations are solved and the flow pattern and heat transfer developing inside the machine are described. The Nusselt number on the stator surfaces has been found. The dependency of the heat transfer on the flow field is described temperature field obtained. Tests on an experimental are undergoing in order to validate the CFD results.
Abstract: This paper presents and discusses the numerical simulations of transient laminar natural convection cooling of high Prandtl number fluids in cubical cavities, in which the six walls of the cavity are subjected to a step change in temperature. The effect of the fluid Prandtl number on the heat transfer coefficient is studied for three different fluids (Golden Syrup, Glycerin and Glycerin-water solution 50%). The simulations are performed at two different Rayleigh numbers (5·106 and 5·107) and six different Prandtl numbers (3 · 105 ≥Pr≥ 50). Heat conduction through the cavity glass walls is also considered. The propsed correlations of the averaged heat transfer coefficient (N u) showed that it is dependant on the initial Ra and almost independent on P r. The instantaneous flow patterns, temperature contours and time evolution of volume averaged temperature and heat transfer coefficient are presented and analyzed.
Abstract: Dew harvesting needs only weak investment and
exploits a free, clean and inexhaustible energy. This study aims to
measure the relative contributions of dew and rain water in the
Mediterranean Dalmatian coast and islands of Croatia and determine
whether dew water is potable. Two sites were chosen, an open site on
the coast favourable to dew formation (Zadar) and a less favourable
site in a circus of mountains in Komiža (Vis Island). Between July
1st, 2003 and October 31st, 2006, dew hasbeen daily collected on a 1
m2 tilted (30°) test dew condenser together with ordinary
meteorological data (air temperature and relative humidity, cloud
coverage, windspeed and direction). The mean yearly cumulative
dew yields were found to be 20 mm (Zadar) and 9.3 mm (Komiža ).
During the dry season (May to October), monthly cumulative dew
water yield can represent up to 38% of water collected by rain fall. In
July 2003 and 2006, dew water represented about 120% of the
monthly cumulative rain water. Dew and rain water were analyzed in
Zadar. The corresponding parameters were measured: pH, electrical
conductivity, major anions (HCO3
-, Cl-, SO4
2-
, NO3
-
, ,) and major
cations (NH4
+, Na+, K+, Ca2+, Mg2+. Both dew and rain water are in
conformity with the WHO directives for potability except Mg2+.
Using existing roofs and refurbishing the abandoned impluviums to
permit dew collection could then provide a useful supplementary
amount of water, especially during the dry season.
Abstract: This article deals with the numerical simulation of the
floor heating convector in 3D. Presented convector can operate in
two modes – cooling mode and heating mode. This initial numerical
simulation is focused on cooling mode of the convector. Models with
different temperature of the fins are compared and three various
shapes of the fins are examined as well. The objective of the work is
to predict air flow and heat transfer inside convector for further
optimalization of these devices. For the numerical simulation was
used commercial software Ansys Fluent.
Abstract: Energy consumption rate during the cooling process
of industrial glass tempering process is considerably high. In this
experimental study the effect of dimensionless jet to jet distance
(S/D) and jet to plate distance (H/D) on the cooling time have been
investigated. In the experiments 4 mm thick glass samples have been
used. Cooling unit consists of 16 mutually placed seamless aluminum
nozzles of 8 mm in diameter and 80 mm in length. Nozzles were in
staggered arrangement. Experiments were conducted with circular
jets for H/D values between 1 and 10, and for S/D values between 2
and 10. During the experiments Reynolds number has been kept
constant at 30000. Experimental results showed that the longest
cooling time with 87 seconds has been observed in the experiments
for S/D=10 and H/D=10 values, while the shortest cooling time with
42.5 seconds has been measured in the experiments for S/D=2 and
H/D=4 values.
Abstract: In this article, using finite element analysis (FEA)
and an X-ray diffractometer (XRD), cold-sprayed titanium particles
on a steel substrate is investigated in term of cooling time and the
development of residual strains. Three cooling-down models of
sprayed particles after deposition stage are simulated and discussed:
the first model (m1) considers conduction effect to the substrate only,
the second model (m2) considers both conduction as well as
convection effect to the environment, and the third model (m3) which
is the same as the second model but with the substrate heated to a
near particle temperature before spraying. Thereafter, residual strains
developed in the third model is compared with the experimental
measurement of residual strains, which involved a Bruker D8
Advance Diffractometer using CuKa radiation (40kV, 40mA)
monochromatised with a graphite sample monochromator. For
deposition conditions of this study, a good correlation was found to
exist between the FEA results and XRD measurements of residual
strains.
Abstract: In a bid to improve turbine entry temperature for maximizing the thermal efficiency of the HP stage gas turbine blade, an attempt is made in this paper to compare the performance of helicoidal ducted blade cooling with turbulator of different geometric proportion. It is found from analysis that there is significant improvement in cooling characteristics for turbine blade with turbulator geometry having larger e/D ratio. Also it is found from analysis, performance is vastly improved for greater thickness of turbulator geometry.
Abstract: An experimental study is realized in order to verify the
Mini Heat Pipe (MHP) concept for cooling high power dissipation
electronic components and determines the potential advantages of
constructing mini channels as an integrated part of a flat heat pipe. A
Flat Mini Heat Pipe (FMHP) prototype including a capillary structure
composed of parallel rectangular microchannels is manufactured and
a filling apparatus is developed in order to charge the FMHP. The
heat transfer improvement obtained by comparing the heat pipe
thermal resistance to the heat conduction thermal resistance of a
copper plate having the same dimensions as the tested FMHP is
demonstrated for different heat input flux rates. Moreover, the heat
transfer in the evaporator and condenser sections are analyzed, and
heat transfer laws are proposed. In the theoretical part of this work, a
detailed mathematical model of a FMHP with axial microchannels is
developed in which the fluid flow is considered along with the heat
and mass transfer processes during evaporation and condensation.
The model is based on the equations for the mass, momentum and
energy conservation, which are written for the evaporator, adiabatic,
and condenser zones. The model, which permits to simulate several
shapes of microchannels, can predict the maximum heat transfer
capacity of FMHP, the optimal fluid mass, and the flow and thermal
parameters along the FMHP. The comparison between experimental
and model results shows the good ability of the numerical model to
predict the axial temperature distribution along the FMHP.
Abstract: In this paper, a new cooling system using a nacelle duct
is proposed for the mechanical room in the household refrigerator. The
conventional mechanical room consists of a condenser, a compressor
and an axial fan. The axial fan is mainly responsible for cooling the
condenser and the compressor. The new cooling system is developed
by replacing the axial fan with the nacelle duct including the small
centrifugal fan. The parametric study is carried out to find the optimum
designs of the nacelle duct in terms of performance and efficiency.
Through this study, it is revealed that the new system can reduce the
space, electrical power and noise compared with the conventional
system
Abstract: Current air conditioning system is using refrigerant as
the cooling medium. The main purpose of this study is to develop an
air conditioning system using chill water as the cooling medium. In
this system, chill water used to replace refrigerant as the cooling
medium. This study is focus on the split type unit air conditioning
system only. It will be involving some renovation on the indoor unit
and freezer. The cooling capability of this system was validate by few
series of testing, which conducted at standard 36m3 office room.
Result of the testing found that 0.1 m3 of chill water is able to
maintain the room temperature within standard up to 4 ~ 8 hours. It
expected able to maintain room temperature up to 10 hour with some
improvement.
Abstract: This study reports the preparation of soft magnetic
ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213
mm and, with a thickness of approximately 22 μm ± 2 μm. The microstructure and magnetic properties of the ribbons were
characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and electrical resistivity measurements (ERM). The amorphous material
properties dependence of the cooling rate and nozzle pressure have uneven surface in ribbon thicknesses are investigated. Magnetic
measurement results indicate that some region of the ribbon exhibits good magnetic properties, higher saturation induction and lower coercivity. However, due to the uneven surface of 213 mm wide
ribbon, the magnetic responses are not uniformly distributed. To
understand the transformer magnetic performances, this study analyzes the measurements of a three-phase 2 MVA amorphous-cored transformer. Experimental results confirm that the transformer with a
ribbon width of 142 mm has better magnetic properties in terms of lower core loss, exciting power, and audible noise.
Abstract: The first and basic cause of the failure of concrete is repeated freezing (thawing) of moisture contained in the pores, microcracks, and cavities of the concrete. On transition to ice, water existing in the free state in cracks increases in volume, expanding the recess in which freezing occurs. A reduction in strength below the initial value is to be expected and further cycle of freezing and thawing have a further marked effect. By using some experimental parameters like nuclear magnetic resonance variation (NMR), enthalpy-temperature (or heat capacity) variation, we can resolve between the various water states and their effect on concrete properties during cooling through the freezing transition temperature range. The main objective of this paper is to describe the principal type of water responsible for the reduction in strength and structural damage (frost damage) of concrete following repeated freeze –thaw cycles. Some experimental work was carried out at the institute of cryogenics to determine what happens to water in concrete during the freezing transition.