Abstract: Experimental investigations were made on the instability of supercritical kerosene flowing in active cooling channels. Two approaches were used to control the pressure in the channel. One is the back-pressure valve while the other is the venturi. In both conditions, a kind of low-frequency oscillation of pressure and temperature is observed. And the oscillation periods are calculated. By comparison with the flow time, it is concluded that the instability occurred in active cooling channels is probably one kind of density wave instability. And its period has no relationship with the cooling channel geometry, nor the pressure, but only depends on the flow time of kerosene in active cooling channels. When the mass flow rate, density and pressure drop couple with each other, the density wave instability will appear.
Abstract: In this paper a numerical technique is used to predict
the metal temperature of a gas turbine vane. The Rising combustor
exit temperatures in gas turbine engines necessitate active cooling for
the downstream turbine section to avoid thermal failure. This study is
performed the solution of external flow, internal convection, and
conduction within the metal vane. Also the trade-off between the
cooling performances in four different hole shapes and configurations
is performed. At first one of the commonly used cooling hole
geometry is investigated; cylindrical holes and then two other
configurations are simulated. The average temperature magnitude in
mid-plan section of each configuration is obtained and finally the
lower temperature value is selected such as best arrangement.