Abstract: Headed reinforcement bars are increasingly used for anchorage in concrete structures. Applications include connections in composite steel-concrete structures, such as beam-column joints, in several strengthening situations as well as in more traditional uses in cast-in-place and precast structural systems. This paper investigates the reduction in the ultimate tensile capacity of embedded cast-in headed anchors due to concrete cracking. A series of nine laboratory tests are carried out to evaluate the influence of cracking on the concrete breakout strength in tension. The experimental results show that cracking affects both the resistance and load-slip response of the headed bar anchors. The strengths measured in these tests are compared to theoretical resistances calculated following the recommendations presented by fib Bulletin no. 58 (2011), ETAG 001 (2010) and ACI 318 (2014). The influences of parameters such as the effective embedment depth (hef), bar diameter (ds), and the concrete compressive strength (fc) are analysed and discussed. The theoretical recommendations are shown to be over-conservative for both embedment depths and were, in general, inaccurate in comparison to the experimental trends. The ACI 318 (2014) was the design code which presented the best performance regarding to the predictions of the ultimate load, with an average of 1.42 for the ratio between the experimental and estimated strengths, standard deviation of 0.36, and coefficient of variation equal to 0.25.
Abstract: Overtopping is known as one the most important reasons for the failure of earth dams. In some cases, it has resulted in heavy damages and losses. Therefore, enhancing the safety of earth dams against overtopping has received much attention in the past four decades. In this paper, at first, the overtopping phenomena and its destructive consequences will be introduced. Then, overtopping failure mechanism of embankments will be described. Finally, different types of protection systems for stabilization of earth dams against overtopping will be presented. These include timber cribs, riprap and gabions, reinforced earth, roller compacted concrete, and the precast concrete blocks.
Abstract: While the use of cast-in-place concrete for an airfield and highway pavement overlay is very common, the application of precast concrete elements is very limited today. The main reasons consist of high production costs and complex structural behavior. Despite that, several precast concrete systems have been developed and tested with the aim to provide a system with rapid construction. The contribution deals with the reinforcement design of a hexagonal element developed for a proposed airfield pavement system. The sub-base course of the system is composed of compacted recycled concrete aggregates and fiber reinforced concrete with recycled aggregates place on top of it. The selected element belongs to a group of precast concrete elements which are being considered for the construction of a surface course. Both high costs of full-scale experiments and the need to investigate various elements force to simulate their behavior in a numerical analysis software by using finite element method instead of performing expensive experiments. The simulation of the selected element was conducted on a nonlinear model in order to obtain such results which could fully compensate results from experiments. The main objective was to design reinforcement of the precast concrete element subject to quasi-static loading from airplanes with respect to geometrical imperfections, manufacturing imperfections, tensile stress in reinforcement, compressive stress in concrete and crack width. The obtained findings demonstrate that the position and the presence of imperfection in a pavement highly affect the stress distribution in the precast concrete element. The precast concrete element should be heavily reinforced to fulfill all the demands. Using under-reinforced concrete elements would lead to the formation of wide cracks and cracks permanently open.
Abstract: Fibre reinforced concrete (FRC) has been widely used in industrial pavements and non-structural elements such as pipes, culverts, tunnels, and precast elements. The strengthening effect of fibres in the concrete matrix is achieved primarily due to the bridging effect of fibres at the crack interfaces. The workability of the concrete was reduced on addition of high percentages of steel fibres. The optimum percentage of addition of steel fibres varies with its aspect ratio. For this study, 1% addition of steel has resulted to be the optimum percentage for both Hooked and Crimped Steel Fibres and was added to the beam specimens. The fibres restrain efficiently the cracks and take up residual stresses beyond the cracking. In this sense, diagonal cracks are effectively stitched up by fibres crossing it. The failure of beams within the shear failure range changed from shear to flexure in the presence of sufficient steel fibre quantity. The shear strength is increased with the addition of steel fibres and had exceeded the enhancement obtained with the transverse reinforcement. However, such increase is not directly in proportion with the quantity of fibres used. Considering all the clarification made in the present experimental investigation, it is concluded that 1% of crimped steel fibres with an aspect ratio of 50 is the best type of steel fibres for replacement of transverse stirrups in high strength concrete beams when compared to the steel fibres with hooked ends.
Abstract: To obtain the high quality and essential workability of mortar, different types of superplasticizers are used. The superplasticizers are the chemical admixture used in the mix to improve the fluidity of mortar. Many factors influenced the superplasticizer to disperse the cement particle in the mortar. Nature and amount of replaced cement by slag, mixing procedure, delayed addition time, and heat stimulation technique of superplasticizer cause the varied effect on the fluidity of the cementitious material. In this experiment, the superplasticizers were heated for 1 hour under 60 °C in a thermostatic chamber. Furthermore, the effect of delayed addition time of heat stimulated superplasticizers (SP) was also analyzed. This method was applied to two types of polycarboxylic acid based ether SP (precast type superplasticizer (SP2) and ready-mix type superplasticizer (SP1)) in combination with a partial replacement of normal Portland cement with blast furnace slag (BFS) with 30% w/c ratio. On the other hands, the fluidity, air content, fresh density, and compressive strength for 7 and 28 days were studied. The results indicate that the addition time and heat stimulation technique improved the flow and air content, decreased the density, and slightly decreased the compressive strength of mortar. Moreover, the slag improved the flow of mortar by increasing the amount of slag, and the effect of external temperature of SP on the flow of mortar was decreased. In comparison, the flow of mortar was improved on 5-minute delay for both kinds of SP, but SP1 has improved the flow in all conditions. Most importantly, the transition points in both types of SP appear to be the same, at about 5±1 min. In addition, the optimum addition time of SP to mortar should be in this period.
Abstract: This paper presents a case study of geotechnical design of bridge foundations and approaches in hilly granite formation in northern New South Wales of Australia. Firstly, the geological formation and existing cut slope conditions which have high risks of rock fall will be described. The bridge has three spans to be constructed using balanced cantilever method with a middle span of 150 m. After concept design option engineering, it was decided to change from pile foundation to pad footing with ground anchor system to optimize the bridge foundation design. The geotechnical design parameters were derived after two staged site investigations. The foundation design was carried out to satisfy both serviceability limit state and ultimate limit state during construction and in operation. It was found that the pad footing design was governed by serviceability limit state design loading cases. The design of bridge foundation also considered presence of weak rock layer intrusion and a layer of “no core” to ensure foundation stability. The precast mass concrete block system was considered for the retaining walls for the bridge approaches to resolve the constructability issue over hilly terrain. The design considered the retaining wall block sliding stability, while the overturning and internal stabilities are satisfied.
Abstract: Polymer concrete (PC) is a distinct concrete with superior characteristics in comparison to ordinary cement concrete. It has become well-known for its applications in thin overlays, floors and precast components. In this investigation, the mechanical properties of PC with different epoxy resin contents, ordinary cement concrete (OCC) and lightweight concrete (LC) have been studied under uniaxial compression test. The study involves five types of concrete, with each type being tested four times. Their complete elastic-plastic behavior was compared with each other through the measurement of volumetric strain during the tests. According to the results, PC showed higher strength, ductility and energy absorption with respect to OCC and LC.
Abstract: The construction industry is currently trying to develop sustainable reinforced concrete structures. In trying to aid in the effort, the research presented in this paper aims to prove the efficiency of modified special hybrid moment frames composed of discretely jointed precast and post-tensioned concrete members. This aim is due to the fact that current design standards do not cover the spatial design of moment frame structures assembled by post-tensioning with special hybrid joints. This lack of standardization is coupled with the fact that previous experimental programs, available in scientific literature, deal mainly with plane structures and offer little information regarding spatial behavior. A spatial model of a modified hybrid moment frame is experimentally analyzed. The experimental results of a natural scale model test of a corner column-beams sub-structure, cut from an actual multilevel building tested to seismic type loading are presented in order to highlight the behavior of this type of structure. The test is performed under alternative cycles of imposed lateral displacements, up to a storey drift ratio of 0.035. Seismic response of the spatial model is discussed considering the acceptance criteria for reinforced concrete frame structures designed based on experimental tests, as well as some of its major sustainability features. The results obtained show an overall excellent behavior of the system. The joint detailing allows for quick and cheap repairs after an accidental event and a self-balancing behavior of the system that ensures it can be used almost immediately after an accidental event it.
Abstract: Experimental and analytical studies were accomplished to examine the structural behavior of precast foamed concrete sandwich panel (PFCSP) under vertical in-plane shear load. PFCSP full-scale specimens with total number of six were developed with varying heights to study an important parameter slenderness ratio (H/t). The production technique of PFCSP and the procedure of test setup were described. The results obtained from the experimental tests were analysed in the context of in-plane shear strength capacity, load-deflection profile, load-strain relationship, slenderness ratio, shear cracking patterns and mode of failure. Analytical study of finite element analysis was implemented and the theoretical calculations of the ultimate in-plane shear strengths using the adopted ACI318 equation for reinforced concrete wall were determined aimed at predicting the in-plane shear strength of PFCSP. The decrease in slenderness ratio from 24 to 14 showed an increase of 26.51% and 21.91% on the ultimate in-plane shear strength capacity as obtained experimentally and in FEA models, respectively. The experimental test results, FEA models data and theoretical calculation values were compared and provided a significant agreement with high degree of accuracy. Therefore, on the basis of the results obtained, PFCSP wall has the potential use as an alternative to the conventional load-bearing wall system.
Abstract: Experimental and analytical studies were carried out to investigate the structural behavior of precast foamed concrete sandwich panels (PFCSP) of total number (6) as one-way action slab tested under lateral load. The details of the test setup and procedures were illustrated. The results obtained from the experimental tests were discussed which include the observation of cracking patterns and influence of aspect ratio (L/b). Analytical study of finite element analysis was implemented and degree of composite action of the test panels was also examined in both experimental and analytical studies. Result shows that crack patterns appeared in only one-direction, similar to reports on solid slabs, particularly when both concrete wythes act in a composite manner. Foamed concrete was briefly reviewed and experimental results were compared with the finite element analyses data which gives a reasonable degree of accuracy. Therefore, based on the results obtained, PFCSP slab can be used as an alternative to conventional flooring system.
Abstract: Failure of typical seismic frames has been found by
plastic hinge occurring on beams section near column faces. On the
other hand, the seismic capacity of the frames can be enhanced if the
plastic hinges of the beams are shifted away from the column faces.
This paper presents detailing of reinforcements in the interior beam–
column connections aiming to relocate the plastic hinge of reinforced
concrete and precast concrete frames. Four specimens were tested
under quasi-static cyclic load including two monolithic specimens
and two precast specimens. For one monolithic specimen, typical
seismic reinforcement was provided and considered as a reference
specimen named M1. The other reinforced concrete frame M2
contained additional intermediate steel in the connection area
compared with the specimen M1. For the precast specimens,
embedded T-section steels in joint were provided, with and without
diagonal bars in the connection area for specimen P1 and P2,
respectively. The test results indicated the ductile failure with beam
flexural failure in monolithic specimen M1 and the intermediate steel
increased strength and improved joint performance of specimen M2.
For the precast specimens, cracks generated at the end of the steel
inserts. However, slipping of reinforcing steel lapped in top of the
beams was seen before yielding of the main bars leading to the brittle
failure. The diagonal bars in precast specimens P2 improved the
connection stiffness and the energy dissipation capacity.
Abstract: Since, it is essential to provide homeless people by the
earthquake with safe, habitable accommodation repairing medium
and slight levels of damage at the connection parts should be
undertaken. In order to prove that a repaired connection was
sufficiently strong, a precast beam to column post tensioned
connection was tested in three phases. In phase one, the middle level
damage was observed at 6% drift at these connections. As a result of
the extra loads applied, little damage was observed. In the last phase,
the four connections tested in the first phase were repaired using
epoxy resin and then retested. The results from the tests on the
repaired precast and the undamaged specimens showed that the
repaired specimens were sufficiently strong, thus proving that repair
to damaged precast beam to column post tensioned connections can
be undertaken.
Abstract: At certain depths during large diameter displacement
pile driving, rebound well over 0.25 inches was experienced,
followed by a small permanent-set during each hammer blow. High
pile rebound (HPR) soils may stop the pile driving and results in a
limited pile capacity. In some cases, rebound leads to pile damage,
delaying the construction project, and the requiring foundations
redesign. HPR was evaluated at seven Florida sites, during driving of
square precast, prestressed concrete piles driven into saturated, fine
silty to clayey sands and sandy clays. Pile Driving Analyzer (PDA)
deflection versus time data recorded during installation, was used to
develop correlations between cone penetrometer (CPT) pore-water
pressures, pile displacements and rebound. At five sites where piles
experienced excessive HPR with minimal set, the pore pressure
yielded very high positive values of greater than 20 tsf. However, at
the site where the pile rebounded, followed by an acceptable
permanent-set, the measured pore pressure ranged between 5 and 20
tsf. The pore pressure exhibited values of less than 5 tsf at the site
where no rebound was noticed. In summary, direct correlations
between CPTu pore pressure and rebound were produced, allowing
identification of soils that produce HPR.
Abstract: Precast residential houses are normally constructed in Malaysia using precast shear-key wall panel and this panel is designed using BS8110 where there is no provision for earthquake. However, the safety of this house under moderate and strong earthquake is still questionable. Consequently, the full-scale of residential house are designed, constructed, tested and analyzed under in-plane lateral quasi-static cyclic loading. Hysteresis loops are plotted based on the experimental work and compared with modeling of hysteresis loops using HYSTERES in RUAUMOKO 2D program. Modified Takeda hysteresis model is chosen to behave a similar pattern with experimental work. This program will display the earthquake excitations, spectral displacements, pseudo spectral acceleration, mode shape and deformation of the structure. It can be concluded that this building is suffering severe cracks and damage under moderate and severe earthquake.
Abstract: Recently, to cope with the rapidly changing
construction trend with aging infrastructures, modular bridge
technology has been studied actively. Modular bridge is easily
constructed by assembling standardized precast structure members in
the field. It will be possible to construct rapidly and reduce
construction cost efficiently. However, the shape of the transverse
connection of T-type girder newly developed between the segmented
modules is not verified. Therefore, the verification of the connection
shape is needed. In this study, shape of the modular T-girder bridge
transverse connection was analyzed by finite element model that was
verified in study which was verified model of transverse connection
using Abaqus. Connection angle was chosen as the parameter. The
result of analyses showed that optimal value of angle is 130 degree.
Abstract: Progressive collapse of buildings typically occurs
when abnormal loading conditions cause local damages, which leads
to a chain reaction of failure and ultimately catastrophic collapse. The
tie force (TF) method is one of the main design approaches for
progressive collapse. As the TF method is a simplified method, further
investigations on the reliability of the method is necessary. This study
aims to develop an improved TF method to design the cross wall
structures for progressive collapse. To this end, the pullout behavior of
strands in grout was firstly analyzed; and then, by considering the tie
force-slip relationship in the friction stage together with the catenary
action mechanism, a comprehensive analytical method was developed.
The reliability of this approach is verified by the experimental results
of concrete block pullout tests and full scale floor-to-floor joints tests
undertaken by Portland Cement Association (PCA). Discrepancies in
the tie force between the analytical results and codified specifications
have suggested the deficiency of TF method, hence an improved
model based on the analytical results has been proposed to address this
concern.
Abstract: Recently in the field of bridges that are newly built or
repaired, fast construction is required more than ever. For these
reasons, precast prefabricated bridge that enables rapid construction is
actively discussed and studied today. In South Korea, it is called
modular bridge. Cross beam is an integral component of modular
bridge. It functions for load distribution, reduction of bending
moment, resistance of horizontal strength on lateral upper structure. In
this study, the structural characteristics of domestic and foreign cross
beam types were compared. Based on this, alternative cross beam
connection types suitable for modular bridge were selected. And
bulb-T girder specimens were fabricated with each type of connection.
The behavior of each specimen was analyzed under static loading, and
cross beam connection type which is expected to be best suited to
modular bridge proposed.
Abstract: A different concept for designing and detailing of
reinforced concrete precast frame structures is analyzed in this paper.
The new detailing of the joints derives from the special hybrid
moment frame joints. The special reinforcements of this alternative
detailing, named modified special hybrid joint, are bondless with
respect to both column and beams. Full scale tests were performed on
a plan model, which represents a part of 5 story structure, cropped in
the middle of the beams and columns spans. Theoretical approach
was developed, based on testing results on twice repaired model,
subjected to lateral seismic type loading. Discussion regarding the
modified special hybrid joint behavior and further on widening
research needed concludes the presentation.
Abstract: Precast concrete has been widely adopted in public
housing construction of Hong Kong since the mid-1980s. While
pre-casting is considered an environmental friendly solution, there is
lack of study to investigate the life cycle performance of precast
concrete units. This study aims to bridge the knowledge gap by
providing a comprehensive life cycle assessment (LCA) study for two
precast elements namely façade and bathroom. The results show that
raw material is the most significant contributor of environmental
impact accounting for about 90% to the total impact. Furthermore,
human health is more affected by the production of precast concrete
than the ecosystems.
Abstract: This study is to evaluate the behavior of integral and
segmental specimens through static and cyclic tests. Integral
specimens were made with the same size to be compared with
segmental specimens that were made by connected precast members.
To evaluate its bending performance and serviceability, 1 integral and
3 segmental specimens were tested under static load. And 1 integral
and 2 segmental specimens were tested under cyclic load, respectively.
Different load ranges were considered in the cyclic tests to evaluate the
safety and serviceability. The test results showed that under static
loading, segmental specimens had about 94% of the integral
specimen's maximum moment, averagely. Under cyclic loading, the
segmental specimens showed that had enough safety in the range of
higher than service load and enough serviceability. In conclusion, the
maximum crack width (0.16mm) satisfied the allowable crack width
(0.30mm) in the range of service load.