Abstract: The world economic crises and budget constraints
have caused authorities, especially those in developing countries, to
rationalize water quality monitoring activities. Rationalization
consists of reducing the number of monitoring sites, the number of
samples, and/or the number of water quality variables measured. The
reduction in water quality variables is usually based on correlation. If
two variables exhibit high correlation, it is an indication that some of
the information produced may be redundant. Consequently, one
variable can be discontinued, and the other continues to be measured.
Later, the ordinary least squares (OLS) regression technique is
employed to reconstitute information about discontinued variable by
using the continuously measured one as an explanatory variable. In
this paper, two record extension techniques are employed to
reconstitute information about discontinued water quality variables,
the OLS and the Line of Organic Correlation (LOC). An empirical
experiment is conducted using water quality records from the Nile
Delta water quality monitoring network in Egypt. The record
extension techniques are compared for their ability to predict
different statistical parameters of the discontinued variables. Results
show that the OLS is better at estimating individual water quality
records. However, results indicate an underestimation of the variance
in the extended records. The LOC technique is superior in preserving
characteristics of the entire distribution and avoids underestimation
of the variance. It is concluded from this study that the OLS can be
used for the substitution of missing values, while LOC is preferable
for inferring statements about the probability distribution.
Abstract: “Garbage enzyme", a fermentation product of kitchen waste, water and brown sugar, is claimed in the media as a multipurpose solution for household and agricultural uses. This study assesses the effects of dilutions (5% to 75%) of garbage enzyme in reducing pollutants in domestic wastewater. The pH of the garbage enzyme was found to be 3.5, BOD concentration about 150 mg/L. Test results showed that the garbage enzyme raised the wastewater-s BOD in proportion to its dilution due to its high organic content. For mixtures with more than 10% garbage enzyme, its pH remained acidic after the 5-day digestion period. However, it seems that ammonia nitrogen and phosphorus could be removed by the addition of the garbage enzyme. The most economic solution for removal of ammonia nitrogen and phosphorus was found to be 9%. Further tests are required to understand the removal mechanisms of the ammonia nitrogen and phosphorus.
Abstract: This paper examines the relationships between and
among the various drivers of climate change that have both climatic
and ecological consequences for vegetation and land cover change in
arctic areas, particularly in arctic Alaska. It discusses the various
processes that have created spatial and climatic structures that have
facilitated observable vegetation and land cover changes in the
Arctic. Also, it indicates that the drivers of both climatic and
ecological changes in the Arctic are multi-faceted and operate in a
system with both positive and negative feedbacks that largely results
in further increases or decreases of the initial drivers of climatic and
vegetation change mainly at the local and regional scales. It
demonstrates that the impact of arctic warming on land cover change
and the Arctic ecosystems is not unidirectional and one dimensional
in nature but it represents a multi-directional and multi-dimensional
forces operating in a feedback system.
Abstract: Nanophotocatalysts such as titanium (TiO2), zinc (ZnO), and iron (Fe2O3) oxides can be used in organic pollutants oxidation, and in many other applications. But among the challenges for technological application (scale-up) of the nanotechnology scientific developments two aspects are still little explored: research on environmental risk of the nanomaterials preparation methods, and the study of nanomaterials properties and/or performance variability. The environmental analysis was performed for six different methods of ZnO nanoparticles synthesis, and showed that it is possible to identify the more environmentally compatible process even at laboratory scale research. The obtained ZnO nanoparticles were tested as photocatalysts, and increased the degradation rate of the Rhodamine B dye up to 30 times.
Abstract: This study was investigated on sampling and
analyzing water quality in water reservoir & water tower installed in
two kind of residential buildings and school facilities. Data of water
quality was collected for correlation analysis with frequency of
sanitization of water reservoir through questioning managers of
building about the inspection charts recorded on equipment for water
reservoir. Statistical software packages (SPSS) were applied to the
data of two groups (cleaning frequency and water quality) for
regression analysis to determine the optimal cleaning frequency of
sanitization. The correlation coefficient (R) in this paper represented
the degree of correlation, with values of R ranging from +1 to -1.After
investigating three categories of drinking water users; this study found
that the frequency of sanitization of water reservoir significantly
influenced the water quality of drinking water. A higher frequency of
sanitization (more than four times per 1 year) implied a higher quality
of drinking water. Results indicated that sanitizing water reservoir &
water tower should at least twice annually for achieving the aim of
safety of drinking water.
Abstract: This study aimed at developing visualization tools for integrating CloudSat images and Water Vapor Satellite images. KML was used for integrating data from CloudSat Satellite and GMS-6 Water Vapor Satellite. CloudSat 2D images were transformed into 3D polygons in order to achieve 3D images. Before overlaying the images on Google Earth, GMS-6 water vapor satellite images had to be rescaled into linear images. Web service was developed using webMathematica. Shoreline from GMS-6 images was compared with shoreline from LandSat images on Google Earth for evaluation. The results showed that shoreline from GMS-6 images was highly matched with the shoreline in LandSat images from Google Earth. For CloudSat images, the visualizations were compared with GMS-6 images on Google Earth. The results showed that CloudSat and GMS-6 images were highly correlated.
Abstract: The benefits of rooftop greenery systems (such as
energy savings, reduction of greenhouse gas emission for mitigating
climate change and maintaining sustainable development, indoor
temperature control etc.) in buildings are well recognized, however
there remains very little research conducted for quantifying the
benefits in subtropical climates such as in Australia. This study
mainly focuses on measuring/determining temperature profile and air
conditioning energy savings by implementing rooftop greenery
systems in subtropical Central Queensland in Australia. An
experimental set-up was installed at Rockhampton campus of Central
Queensland University, where two standard shipping containers (6m
x 2.4m x 2.4m) were converted into small offices, one with green
roof and one without. These were used for temperature, humidity and
energy consumption data collection. The study found that an energy
savings of up to 11.70% and temperature difference of up to 4°C can
be achieved in March in subtropical Central Queensland climate in
Australia. It is expected that more energy can be saved in peak
summer days (December/February) as temperature difference
between green roof and non-green roof is higher in December-
February.
Abstract: Modern managements of water distribution system
(WDS) need water quality models that are able to accurately predict
the dynamics of water quality variations within the distribution system
environment. Before water quality models can be applied to solve
system problems, they should be calibrated. Although former
researchers use GA solver to calibrate relative parameters, it is
difficult to apply on the large-scale or medium-scale real system for
long computational time. In this paper a new method is designed
which combines both macro and detailed model to optimize the water
quality parameters. This new combinational algorithm uses radial
basis function (RBF) metamodeling as a surrogate to be optimized for
the purpose of decreasing the times of time-consuming water quality
simulation and can realize rapidly the calibration of pipe wall reaction
coefficients of chlorine model of large-scaled WDS. After two cases
study this method is testified to be more efficient and promising, and
deserve to generalize in the future.
Abstract: In this paper, the implementation of a rule-based
intuitive reasoner is presented. The implementation included two
parts: the rule induction module and the intuitive reasoner. A large
weather database was acquired as the data source. Twelve weather
variables from those data were chosen as the “target variables"
whose values were predicted by the intuitive reasoner. A “complex"
situation was simulated by making only subsets of the data available
to the rule induction module. As a result, the rules induced were
based on incomplete information with variable levels of certainty.
The certainty level was modeled by a metric called "Strength of
Belief", which was assigned to each rule or datum as ancillary
information about the confidence in its accuracy. Two techniques
were employed to induce rules from the data subsets: decision tree
and multi-polynomial regression, respectively for the discrete and the
continuous type of target variables. The intuitive reasoner was tested
for its ability to use the induced rules to predict the classes of the
discrete target variables and the values of the continuous target
variables. The intuitive reasoner implemented two types of
reasoning: fast and broad where, by analogy to human thought, the
former corresponds to fast decision making and the latter to deeper
contemplation. . For reference, a weather data analysis approach
which had been applied on similar tasks was adopted to analyze the
complete database and create predictive models for the same 12
target variables. The values predicted by the intuitive reasoner and
the reference approach were compared with actual data. The intuitive
reasoner reached near-100% accuracy for two continuous target
variables. For the discrete target variables, the intuitive reasoner
predicted at least 70% as accurately as the reference reasoner. Since
the intuitive reasoner operated on rules derived from only about 10%
of the total data, it demonstrated the potential advantages in dealing
with sparse data sets as compared with conventional methods.
Abstract: The distribution, enrichment, accumulation, and potential ecological risk of copper (Cu) in the surface sediments of northern Kaohsiung Harbor, Taiwan were investigated. Sediment samples from 12 locations of northern Kaohsiung Harbor were collected and characterized for Cu, aluminum, water content, organic matter, total nitrogen, total phosphorous, total grease and grain size. Results showed that the Cu concentrations varied from 6.9–244 mg/kg with an average of 109±66 mg/kg. The spatial distribution of Cu reveals that the Cu concentration is relatively high in the river mouth region, and gradually diminishes toward the harbor entrance region. This indicates that upstream industrial and municipal wastewater discharges along the river bank are major sources of Cu pollution. Results from the enrichment factor and geo-accumulation index analyses imply that the sediments collected from the river mouth can be characterized between moderate and moderately severe degree enrichment and between none to medium and moderate accumulation of Cu, respectively. However, results of potential ecological risk index indicate that the sediment has low ecological potential risk.
Abstract: This research aims to study the lead pollution in the air of Babylon governorate that resulted generally from vehicles exhausts in addition to industrial and human activities.Vehicles number in Babylon governorate increased significantly after year 2003 that resulted with increase in lead emissions into the air.Measurement of lead emissions was done in seven stations distributed randomly in Babylon governorate. These stations where located in Industrial (Al-Sena'ay) Quarter, 60 street (near to Babylon sewer directorate), 40 Street (near to the first intersection), Al-Hashmia city, Al-Mahaweel city, , Al- Musayab city in addition to another station in Sayd Idris village belong to Abugharaq district (Agricultural station for comparison). The measured concentrations in these stations were compared with the standard limits of Environmental Protection Agency EPA (2 μg /m3). The results of this study showed that the average of lead concentrations ,in Babylon governorate during year 2010, was (3.13 μg/m3) which was greater than standard limits (2 μg/m3). The maximum concentration of lead was (6.41 μg / m3) recorded in the Industrial (Al-Sena'ay) Quarter during April month, while the minimum concentrations was (0.36 μg / m3) recorded in the agricultural station (Abugharaq) during December month.
Abstract: Demand of energy is increasing faster than the
generation. It leads shortage of power in all sectors of society. At
peak hours this shortage is higher. Unless we utilize energy efficient
technology, it is very difficult to minimize the shortage of energy. So
energy efficiency program and energy conservation has an important
role. Energy efficient technologies are cost intensive hence it is
always not possible to implement in country like India. In the recent
study, an educational building with operating hours from 10:00 a.m.
to 05:00 p.m. has been selected to quantify the possibility of lighting
energy conservation. As the operating hour is in daytime, integration
of daylight with artificial lighting system will definitely reduce the
lighting energy consumption. Moreover the initial investment has
been given priority and hence the existing lighting installation was
unaltered. An automatic controller has been designed which will be
operated as a function of daylight through windows and the lighting
system of the room will function accordingly. The result of the study
of integrating daylight gave quite satisfactory for visual comfort as
well as energy conservation.
Abstract: The Beshar River is one aquatic ecosystem, which is
located next to the city of Yasuj in southern Iran. The Beshar river
has been contaminated by industrial factories such as effluent of
sugar factory, agricultural and other activities in this region such as,
Imam Sajjad hospital, drainage from agricultural farms, Yasuj urban
surface runoff and effluent of wastewater treatment plants ,specially
Yasuj waste water treatment plant. In order to evaluate the effects of
these pollutants on the quality of the Beshar river, five monitoring
stations were selected along its course. The first station is located
upstream of Yasuj near the Dehnow village; stations 2 to 4 are
located east, south and west of city; and the 5th station is located
downstream of Yasuj. Several water quality parameters were
sampled. These include pH, dissolved oxygen, biological oxygen
demand (BOD), temperature, conductivity, turbidity, total dissolved
solids and discharge or flow measurements. Water samples from the
five stations were collected and analyzed to determine the following
physicochemical parameters: EC, pH, T.D.S, T.H, No2, DO, BOD5,
COD during 2008 to 2010. The study shows that the BOD5 value of
station 1 is at a minimum (1.7 ppm) and increases downstream from
stations 2 to 4 to a maximum (11.6 ppm), and then decreases at
station 5. The DO values of station 1 is a maximum (8.45 ppm),
decreases downstream to stations 2 - 4 which are at a minimum (3.1
ppm), before increasing at station 5. The amount of BOD and TDS
are highest at the 4th station and the amount of DO is lowest at this
station, marking the 4th station as more highly polluted than the
other stations .This study shows average amount of the water quality
parameters in first year of sampling (2008) have had a better quality
relation to third year in 2010 because of recent drought in this region
and pollutant increasing .As the Beshar river path after 5th station
goes through the mountain area with more slope and flow velocity
,so the physicochemical parameters improve at the 5th station due to
pollutant degradation and dilution. Finally the point and nonpoint
pollutant sources of Beshar river were determined and compared to
the monitoring results.
Abstract: This paper aims to develop a NOx emission model of
an acid gas incinerator using Nelder-Mead least squares support
vector regression (LS-SVR). Malaysia DOE is actively imposing the
Clean Air Regulation to mandate the installation of analytical
instrumentation known as Continuous Emission Monitoring System
(CEMS) to report emission level online to DOE . As a hardware
based analyzer, CEMS is expensive, maintenance intensive and often
unreliable. Therefore, software predictive technique is often
preferred and considered as a feasible alternative to replace the
CEMS for regulatory compliance. The LS-SVR model is built based
on the emissions from an acid gas incinerator that operates in a LNG
Complex. Simulated Annealing (SA) is first used to determine the
initial hyperparameters which are then further optimized based on the
performance of the model using Nelder-Mead simplex algorithm.
The LS-SVR model is shown to outperform a benchmark model
based on backpropagation neural networks (BPNN) in both training
and testing data.
Abstract: Study was conducted to determine the concentration of
copper, cadmium, lead and zinc in Cabomba furcata that found
abundance in Lake Chini. This aquatic plant was collected randomly
within the lake for heavy metal determination. Water quality
measurement was undertaken in situ for temperature, pH,
conductivity and dissolved oksigen using portable multi sensor probe
YSI model 556. The C. furcata was digested using wet digestion
method and heavy metal concentrations were analysed using Atomic
Absorption Spectrometer (AAS) Perkin Elmer 4100B (flame
method). Result of water quality classify Lake Chini between class II
to class III using Malaysian Water Quality Standard. According to
this standard, Lake Chini has moderate quality, which normal for
natural lake. Heavy metal concentrations in C.furcata were low and
found to be lower than the critical toxic value in aquatic plants. Oneway
ANOVA test indicated the heavy metal concentrations in
C.furcata were significantly differ between sampling location. Water
quality and heavy metal concentrations indicates that Lake Chini was
not receives anthropogenic load from nearby activities.
Abstract: The technique of inducing micro ecosystem
restoration is one of aquatic ecology engineering methods used to
retrieve the polluted water. Batch scale study, pilot plant study, and
field study were carried out to observe the eutrophication using the
Inducing Ecology Restorative Symbiosis Agent (IERSA) consisting
mainly degraded products by using lactobacillus, saccharomycete,
and phycomycete. The results obtained from the experiments of the
batch scale and pilot plant study allowed us to development the
parameters for the field study. A pond, 5 m to the outlet of a lake,
with an area of 500 m2 and depth of 0.6-1.2 m containing about 500
tons of water was selected as a model. After the treatment with 10
mg IERSA/L water twice a week for 70 days, the micro restoration
mechanisms consisted of three stages (i.e., restoration, impact
maintenance, and ecology recovery experiment after impact). The
COD, TN, TKN, and chlorophyll a were reduced significantly in the
first week. Although the unexpected heavy rain and contaminate
from sewage system might slow the ecology restoration. However,
the self-cleaning function continued and the chlorophyll a reduced
for 50% in one month. In the 4th week, amoeba, paramecium, rotifer,
and red wriggle worm reappeared, and the number of fish flies
appeared up to1000 fish fries/m3. Those results proved that inducing
restorative mechanism can be applied to improve the eutrophication
and to control the growth of algae in the lakes by gaining the selfcleaning
through inducing and competition of microbes. The
situation for growth of fishes also can reach an excellent result due to
the improvement of water quality.
Abstract: Five vegetables (spinach, lettuce, cabbage, tomato, and onion) were freshly harvested from the Alau Dam and Gongulong agricultural areas for the determination of some organochlorine pesticide residues (o, p-DDE, p,p’-DDD, o,p’-DDD, p,p’-DDT, α-BHC, γ-BHC, metoxichlor, lindane, endosulfan dieldrin, and aldrin.) Soil samples were also collected at different depths for the determination of the above pesticides. Samples collection and preparation were conducted using standard procedures. The concentrations of all the pesticides in the soil and vegetable samples were determined using GC/MS SHIMADZU (GC-17A) equipped with electron capture detector (ECD). The highest concentration was that of p,p’-DDD (132.4±13.45µg/g) which was observed in the leaf of cabbage, while the lowest concentration was that of p,p’-DDT (2.34µg/g) was observed in the root of spinach. Similar trends were observed at the Gongulong agricultural area, with p,p’-DDD having the highest concentration of 153.23µg/g in the leaf of cabbage, while the lowest concentration was that of p,p’-DDT (12.45µg/g) which was observed in the root of spinach. α-BHC, γ-BHC, Methoxychlor, and lindane were detected in all the vegetable samples studied. The concentrations of all the pesticides in the soil samples were observed to be higher at a depth of 21-30cm, while the lowest concentrations were observed at a depth of 0-10cm. The concentrations of all the pesticides in the vegetables and soil samples from the two agricultural sites were observed to be at alarming levels, much higher than the maximum residue limits (MRLs) and acceptable daily intake values (ADIs) .The levels of the pesticides observed in the vegetables and soil samples investigated, are of such a magnitude that calls for special attention and laws to regulate the use and circulation of such chemicals. Routine monitoring of pesticide residues in these study areas is necessary for the prevention, control and reduction of environmental pollution, so as to minimize health risks.
Abstract: It is essential to have a uniform and calm flow field
for a settling tank to have high performance. In general, the
recirculation zones always occurred in sedimentation tanks. The
presence of these regions may have different effects. The nonuniformity
of the velocity field, the short-circuiting at the surface and
the motion of the jet at the bed of the tank that occurs because of the
recirculation in the sedimentation layer, are affected by the geometry
of the tank. There are some ways to decrease the size of these dead
zones, which would increase the performance. One of the ways is to
use a suitable baffle configuration. In this study, the presence of
baffle with different position has been investigated by a finite volume
method, with VOF (Volume of Fluid) model. Besides, the k-ε
turbulence model is used in the numerical calculations. The results
indicate that the best position of the baffle is obtained when the
volume of the recirculation region is minimized or is divided to
smaller part and the flow field trend to be uniform in the settling
zone.
Abstract: An autonomous environmental monitoring system
(Smart Landfill) has been constructed for the quantitative
measurement of the components of landfill gas found at borehole
wells at the perimeter of landfill sites. The main components of
landfill gas are the greenhouse gases, methane and carbon dioxide
and have been monitored in the range 0-5 % volume. This monitoring
system has not only been tested in the laboratory but has been
deployed in multiple field trials and the data collected successfully
compared with on-site monitors. This success shows the potential of
this system for application in environments where reliable gas
monitoring is crucial.
Abstract: Different agricultural waste peels were assessed for
their suitability to be used as primary substrates for the
bioremediation of free cyanide (CN-) by a cyanide-degrading fungus
Aspergillus awamori isolated from cyanide containing wastewater.
The bioremediated CN- concentration were in the range of 36 to 110
mg CN-/L, with Orange (C. sinensis) > Carrot (D. carota) > Onion
(A. cepa) > Apple (M. pumila), being chosen as suitable substrates
for large scale CN- degradation processes due to: 1) the high
concentration of bioremediated CN-, 2) total reduced sugars released
into solution to sustain the biocatalyst, and 3) minimal residual NH4-
N concentration after fermentation. The bioremediation rate constants
(k) were 0.017h-1 (0h < t < 24h), with improved bioremediation rates
(0.02189h-1) observed after 24h. The averaged nitrilase activity was
~10 U/L.