Abstract: In this experiment, we investigated the performance of
two types of heat sink, swaged- and extruded-type, used in the inverter
of industrial electricity generator. The swaged-type heat sink has 62
fins, and the extruded-type has 38 fins having the same dimension as
that of the swaged-type. But the extruded-type heat sink maintains the
same heat transfer area by the laterally waved surface which has 1 mm
in radius. As a result, the swaged- and extruded-type heat sinks
released 71% and 64% of the heat incoming to the heat sink,
respectively. The other incoming heat were naturally convected and
radiated to the ambient. In spite of 40% decrease in number of fins, the
heat release performance of the extruded-type heat sink was lowered
only 7% than that of the swaged-type. We believe that, this shows the
increment of effective heat transfer area by the laterally waved surface
of fins and the better heat transfer property of the extruded-type heat
sink.