Abstract: Continuous carbon fiber reinforced plastics (CFRP) exhibit a high application potential for lightweight structures due to their outstanding specific mechanical properties. Embedded metal elements, so-called inserts, can be used to join structural CFRP parts. Drilling of the components to be joined can be avoided using inserts. In consequence, no bearing stress is anticipated. This is a distinctive benefit of embedded inserts, since continuous CFRP have low shear and bearing strength. This paper aims at the investigation of the load bearing capacity after preinduced damages from impact tests and thermal-cycling. In addition, characterization of mechanical properties during dynamic high speed pull-out testing under different loading velocities was conducted. It has been shown that the load bearing capacity increases up to 100% for very high velocities (15 m/s) in comparison with quasi-static loading conditions (1.5 mm/min). Residual strength measurements identified the influence of thermal loading and preinduced mechanical damage. For both, the residual strength was evaluated afterwards by quasi-static pull-out tests. Taking into account the DIN EN 6038 a high decrease of force occurs at impact energy of 16 J with significant damage of the laminate. Lower impact energies of 6 J, 9 J, and 12 J do not decrease the measured residual strength, although the laminate is visibly damaged - distinguished by cracks on the rear side. To evaluate the influence of thermal loading, the specimens were placed in a climate chamber and were exposed to various numbers of temperature cycles. One cycle took 1.5 hours from -40 °C to +80 °C. It could be shown that already 10 temperature cycles decrease the load bearing capacity up to 20%. Further reduction of the residual strength with increasing number of thermal cycles was not observed. Thus, it implies that the maximum damage of the composite is already induced after 10 temperature cycles.
Abstract: Continually increasing working temperature and growing need for greater efficiency and reliability of automotive exhaust require systematic investigation into the thermal fatigue properties especially of high temperature stainless steels. In this study, thermal fatigue properties of 300 series austenitic stainless steels have been evaluated in the temperature ranges of 200-800oC and 200-900oC. Systematic methods for control of temperatures within the predetermined range and measurement of load applied to specimens as a function of temperature during thermal cycles have been established. Thermal fatigue tests were conducted under fully constrained condition, where both ends of specimens were completely fixed. Load relaxation behavior at the temperatures of thermal cycle was closely related with the thermal fatigue property.
Abstract: This study describes a micro device integrated with
multi-chamber for polymerase chain reaction (PCR) with different
annealing temperatures. The device consists of the reaction
polydimethylsiloxane (PDMS) chip, a cover glass chip, and is
equipped with cartridge heaters, fans, and thermocouples for
temperature control. In this prototype, commercial software is utilized
to determine the geometric and operational parameters those are
responsible for creating the denaturation, annealing, and extension
temperatures within the chip. Two cartridge heaters are placed at two
sides of the chip and maintained at two different temperatures to
achieve a thermal gradient on the chip during the annealing step. The
temperatures on the chip surface are measured via an infrared imager.
Some thermocouples inserted into the reaction chambers are used to
obtain the transient temperature profiles of the reaction chambers
during several thermal cycles. The experimental temperatures
compared to the simulated results show a similar trend. This work
should be interesting to persons involved in the high-temperature
based reactions and genomics or cell analysis.
Abstract: Since polymerase chain reaction (PCR) has been
invented, it has emerged as a powerful tool in genetic analysis. The
PCR products are closely linked with thermal cycles. Therefore, to
reduce the reaction time and make temperature distribution uniform in
the reaction chamber, a novel oscillatory thermal cycler is designed.
The sample is placed in a fixed chamber, and three constant isothermal
zones are established and lined in the system. The sample is oscillated
and contacted with three different isothermal zones to complete
thermal cycles. This study presents the design of the geometric
characteristics of the chamber. The commercial software
CFD-ACE+TM is utilized to investigate the influences of various
materials, heating times, chamber volumes, and moving speed of the
chamber on the temperature distributions inside the chamber. The
chamber moves at a specific velocity and the boundary conditions
with time variations are related to the moving speed. Whereas the
chamber moves, the boundary is specified at the conditions of the
convection or the uniform temperature. The user subroutines compiled
by the FORTRAN language are used to make the numerical results
realistically. Results show that the reaction chamber with a rectangular
prism is heated on six faces; the effects of various moving speeds of
the chamber on the temperature distributions are examined. Regarding
to the temperature profiles and the standard deviation of the
temperature at the Y-cut cross section, the non-uniform temperature
inside chamber is found as the moving speed is larger than 0.01 m/s.
By reducing the heating faces to four, the standard deviation of the
temperature of the reaction chamber is under 1.4×10-3K with the range
of velocities between 0.0001 m/s and 1 m/s. The nature convective
boundary conditions are set at all boundaries while the chamber moves
between two heaters, the effects of various moving velocities of the
chamber on the temperature distributions are negligible at the assigned
time duration.
Abstract: This study describes a capillary-based device
integrated with the heating and cooling modules for polymerase chain
reaction (PCR). The device consists of the reaction
polytetrafluoroethylene (PTFE) capillary, the aluminum blocks, and is
equipped with two cartridge heaters, a thermoelectric (TE) cooler, a
fan, and some thermocouples for temperature control. The cartridge
heaters are placed into the heating blocks and maintained at two
different temperatures to achieve the denaturation and the extension
step. Some thermocouples inserted into the capillary are used to obtain
the transient temperature profiles of the reaction sample during
thermal cycles. A 483-bp DNA template is amplified successfully in
the designed system and the traditional thermal cycler. This work
should be interesting to persons involved in the high-temperature
based reactions and genomics or cell analysis.