Abstract: Tubular linear induction motor (TLIM) can be used as a capsule pump in a large pneumatic capsule pipeline (PCP) system. Parametric performance evaluation of the designed 1-meter diameter PCP-TLIM system yields encouraging results for practical implementation. The capsule thrust and speed inside the TLIM pump can be calculated from the combination of the PCP fluid mechanics and the TLIM equations. The TLIM equivalent circuits derived from those of the conventional three-phase induction motor are used as a model to predict the static test results of a small-scale PCP-TLIM system. In this paper, additional dynamic tests are performed on the same small-scale PCP-TLIM system with two capsules of different diameters. The behaviors of the capsule inside the pump are observed and analyzed. The dynamic performances from the dynamic tests are compared with the theoretical predictions based on the TLIM equivalent circuit model.
Abstract: This paper describes the experimental efficiency of a
compact organic Rankine cycle (ORC) system with a compact
rotary-vane-type expander. The compact ORC system can be used for
power generation from low-temperature heat sources such as waste
heat from various small-scale heat engines, fuel cells, electric devices,
and solar thermal energy. The purpose of this study is to develop an
ORC system with a low power output of less than 1 kW with a hot
temperature source ranging from 60°C to 100°C and a cold
temperature source ranging from 10°C to 30°C. The power output of
the system is rather less due to limited heat efficiency. Therefore, the
system should have an economically optimal efficiency. In order to
realize such a system, an efficient and low-cost expander is
indispensable. An experimental ORC system was developed using the
rotary-vane-type expander which is one of possible candidates of the
expander. The experimental results revealed the expander
performance for various rotation speeds, expander efficiencies, and
thermal efficiencies. Approximately 30 W of expander power output
with 48% expander efficiency and 4% thermal efficiency with a
temperature difference between the hot and cold sources of 80°C was
achieved.
Abstract: With data centers, end-users can realize the pervasiveness of services that will be one day the cornerstone of our lives. However, data centers are often classified as computing systems that consume the most amounts of power. To circumvent such a problem, we propose a self-adaptive weighted sum methodology that jointly optimizes the performance and power consumption of any given data center. Compared to traditional methodologies for multi-objective optimization problems, the proposed self-adaptive weighted sum technique does not rely on a systematical change of weights during the optimization procedure. The proposed technique is compared with the greedy and LR heuristics for large-scale problems, and the optimal solution for small-scale problems implemented in LINDO. the experimental results revealed that the proposed selfadaptive weighted sum technique outperforms both of the heuristics and projects a competitive performance compared to the optimal solution.
Abstract: This paper demonstrates an effort of a serviceoriented
engineering department in improving the sharing and
transfer of knowledge. Although the department consist of only six
employees, but it provides services in various chemical application in
an oil and gas business. The services provided span across Asia
Pacific region mainly Indonesia, Myanmar, Vietnam, Brunei,
Thailand and Singapore. Currently there are no effective tools or
integrated systems that support the sharing or transfer and
maintenance of knowledge so the department has considered
preserving this valuable knowledge by developing a Knowledge
Management System (KMS). This paper presents the development of
a KMS to support the sharing of knowledge in a service-oriented
engineering department of an oil and gas company. The embedded
features in the KMS like blog and forum will encourage iterative
process of knowledge sharing among the employees in the
department. The information and knowledge being shared, discussed
and communicated will be then achieved for future re-use. The re-use
of the knowledge allows the department to reduce redundant efforts
in providing consistent, up-to-date and cost effective of the best
solution to the its clients.
Abstract: In this study, in order to clarify wind-induced
phenomena, especially vertical mixing of density stratification in a
closed water area with floating-leaved plants, we conducted hydraulic
experiments on wind flow characteristics, wind wave characteristics,
entrainment phenomena and turbulent structure by using a wind tunnel
test tank and simulated floating-leaved plants. From the experimental
results of wind flow and wind wave characteristics, we quantified the
impact of the occupancy rate of the plants on their resistance
characteristics. From the experimental results of entrainment
phenomena, we defined the parameter that could explain the
magnitude of mixing between the density stratifications, and
quantified the impact of the occupancy rate on vertical mixing
between stratifications. From the experimental results of the turbulent
structure of the upper layer, we clarified the differences in small-scale
turbulence components at each occupancy rate and quantified the
impact of the occupancy rate on the turbulence characteristics. For a
summary of this study, we theoretically quantified wind-induced
entrainment phenomena in a closed water area with luxuriant growth
of floating-leaved plants. The results indicated that the impact of
luxuriant growth of floating-leaved plants in a closed water body
could be seen in the difference in small-scale fluid characteristics, and
these characteristics could be expressed using the small-scale
turbulent components.
Abstract: A high performance clarification system has been
discussed for advanced aqueous reprocessing of FBR spent fuel.
Dissolver residue gives the cause of troubles on the plant operation of
reprocessing. In this study, the new clarification system based on the
hybrid of centrifuge and filtration was proposed to get the high
separation ability of the component of whole insoluble sludge. The
clarification tests of simulated solid species were carried out to
evaluate the clarification performance using small-scale test apparatus
of centrifuge and filter unit. The density effect of solid species on the
collection efficiency was mainly evaluated in the centrifugal
clarification test. In the filtration test using ceramic filter with pore
size of 0.2μm, on the other hand, permeability and filtration rate
were evaluated in addition to the filtration efficiency. As results, it was
evaluated that the collection efficiency of solid species on the new
clarification system was estimated as nearly 100%. In conclusion, the
high clarification performance of dissolver liquor can be achieved by
the hybrid of the centrifuge and filtration system.
Abstract: Majority of pepper farmers in Malaysia are using the
open-sun method for drying the pepper berries. This method is time
consuming and exposed the berries to rain and contamination. A
maintenance-friendly and properly enclosed dryer is therefore
desired. A dryer design with a solar collector and a chimney was
studied and adapted to suit the needs of small-scale pepper farmers in
Malaysia. The dryer will provide an environment with an optimum
operating temperature meant for drying pepper berries. The dryer
model was evaluated by using commercially available computational
fluid dynamic (CFD) software in order to understand the heat and
mass transfer inside the dryer. Natural convection was the only mode
of heat transportation considered in this study as in accordance to the
idea of having a simple and maintenance-friendly design. To
accommodate the effect of low buoyancy found in natural convection
driers, a biomass burner was integrated into the solar dryer design.