Abstract: Elastomeric bearings (EB) are used in many applications, such as base isolation of bridges, seismic protection and vibration control of other structures and machinery. Their versatility is due to their particular behavior since they have different stiffness in the vertical and horizontal directions, allowing to sustain vertical loads and at the same time horizontal displacements. Therefore, vertical, horizontal and bending stiffnesses are important parameters to take into account in the design of EB. In order to acquire a proper design methodology of EB all three, theoretical, finite element analysis and experimental, approaches should be taken into account to assess stability due to different loading states, predict their behavior and consequently their effects on the dynamic response of structures, and understand complex behavior and properties of rubber-like materials respectively. In particular, the recent large-displacement theory on the stability of EB formulated by Forcellini and Kelly is validated with both numerical simulations using the finite element method, and experimental results set at the University of Antioquia in Medellin, Colombia. In this regard, this study reproduces the behavior of EB under compression loads and investigates the stability behavior with the three mentioned points of view.
Abstract: The hi-tech industries in the Science Park at southern Taiwan were heavily damaged by a strong earthquake early 2016. The financial loss in this event was attributed primarily to the automated stocker system handling fully processed products, and recovery of the automated stocker system from the aftermath proved to contribute major lead time. Therefore, development of effective means for protection of stockers against earthquakes has become the highest priority for risk minimization and business continuity. This study proposes to mitigate the seismic response of the stockers by introducing viscous fluid dampers in between the ceiling and the top of the stockers. The stocker is expected to vibrate less violently with a passive control force on top. Linear damper is considered in this application with an optimal damping coefficient determined from a preliminary parametric study. The damper is small in size in comparison with those adopted for building or bridge applications. Component test of the dampers has been carried out to make sure they meet the design requirement. Shake table tests have been further conducted to verify the proposed scheme under realistic earthquake conditions. Encouraging results have been achieved by effectively reducing the seismic responses of up to 60% and preventing the FOUPs from falling off the shelves that would otherwise be the case if left unprotected. Effectiveness of adopting a viscous fluid damper for seismic control of the stocker on top against the ceiling has been confirmed. This technique has been adopted by Macronix International Co., LTD for seismic retrofit of existing stockers. Demonstrative projects on the application of the proposed technique are planned underway for other companies in the display industry as well.
Abstract: Standard routes for upgrading existing buildings to improve their seismic response can be expensive in terms of both time and cost due to the modifications required to the foundations. As a result, interest has grown in the installation of viscoelastic dampers (VEDs) in mid and high-rise buildings. Details of a low-cost viscoelastic passive control device, the rotary rubber braced damper (RRBD), are presented in this paper. This design has the added benefits of being lightweight and simple to install. Experimental methods and finite element modeling were used to assess the performance of the proposed VED design and its effect on building response during earthquakes. The analyses took into account the behaviors of non-linear materials and large deformations. The results indicate that the proposed RRBD provides high levels of energy absorption, ensuring the stable cyclical response of buildings in all scenarios considered. In addition, time history analysis was employed in this study to evaluate the RRBD’s ability to control the displacements and accelerations experienced by steel frame structures. It was demonstrated that the device responds well even at low displacements, highlighting its suitability for use in seismic events of varying severity.
Abstract: Housings in developing countries have often inadequate
seismic protection, particularly for masonry. People choose this type
of structure since the cost and application are relatively cheap.
Seismic protection of masonry remains an interesting issue among
researchers. In this study, we develop a low-cost seismic isolation
system for masonry using fiber reinforced elastomeric isolators. The
elastomer proposed consists of few layers of rubber pads and fiber
lamina, making it lower in cost comparing to the conventional
isolators. We present a finite element (FE) analysis to predict the
behavior of the low cost rubber isolators undergoing moderate
deformations. The FE model of the elastomer involves a hyperelastic
material property for the rubber pad. We adopt a Yeoh hyperelasticity
model and estimate its coefficients through the available experimental
data. Having the shear behavior of the elastomers, we apply that
isolation system onto small masonry housing. To attach the isolators
on the building, we model the shear behavior of the isolation system
by means of a damped nonlinear spring model. By this attempt, the
FE analysis becomes computationally inexpensive. Several ground
motion data are applied to observe its sensitivity. Roof acceleration
and tensile damage of walls become the parameters to evaluate
the performance of the isolators. In this study, a concrete damage
plasticity model is used to model masonry in the nonlinear range.
This tool is available in the standard package of Abaqus FE software.
Finally, the results show that the low-cost isolators proposed are
capable of reducing roof acceleration and damage level of masonry
housing. Through this study, we are also capable of monitoring the
shear deformation of isolators during seismic motion. It is useful to
determine whether the isolator is applicable. According to the results,
the deformations of isolators on the benchmark one story building are
relatively small.
Abstract: In this paper, a summary of analytical and
experimental studies into the behavior of a new hysteretic damper,
designed for seismic protection of structures is presented. The Multidirectional
Torsional Hysteretic Damper (MRSD) is a patented
invention in which a symmetrical arrangement of identical cylindrical
steel cores is so configured as to yield in torsion while the structure
experiences planar movements due to earthquake shakings. The new
device has certain desirable properties. Notably, it is characterized by
a variable and controllable-via-design post-elastic stiffness. The
mentioned property is a result of MRSD’s kinematic configuration
which produces this geometric hardening, rather than being a
secondary large-displacement effect. Additionally, the new system is
capable of reaching high force and displacement capacities, shows
high levels of damping, and very stable cyclic response. The device
has gone through many stages of design refinement, multiple
prototype verification tests and development of design guide-lines
and computer codes to facilitate its implementation in practice.
Practicality of the new device, as offspring of an academic sphere, is
assured through extensive collaboration with industry in its final
design stages, prototyping and verification test programs.
Abstract: The paper presents a plastic analysis procedure based
on the energy balance concept for performance based seismic retrofit
of multi-story multi-bay masonry infilled reinforced concrete (R/C)
frames with a ‘soft’ ground story using passive energy dissipation
(PED) devices with the objective of achieving a target performance
level of the retrofitted R/C frame for a given seismic hazard level at
the building site. The proposed energy based plastic analysis
procedure was employed for developing performance based design
(PBD) formulations for PED devices for a simulated application in
seismic retrofit of existing frame structures designed in compliance
with the prevalent standard codes of practice. The PBD formulations
developed for PED devices were implemented for simulated seismic
retrofit of a representative code-compliant masonry infilled R/C
frame with a ‘soft’ ground story using friction dampers as the PED
device. Non-linear dynamic analyses of the retrofitted masonry
infilled R/C frames is performed to investigate the efficacy and
accuracy of the proposed energy based plastic analysis procedure in
achieving the target performance level under design level
earthquakes. Results of non-linear dynamic analyses demonstrate that
the maximum inter-story drifts in the masonry infilled R/C frames
with a ‘soft’ ground story that is retrofitted with the friction dampers
designed using the proposed PBD formulations are controlled within
the target drifts under near-field as well far-field earthquakes.