Abstract: The excellent suitability of the externally excited synchronous
machine (EESM) in automotive traction drive applications
is justified by its high efficiency over the whole operation range and
the high availability of materials. Usually, maximum efficiency is
obtained by modelling each single loss and minimizing the sum of all
losses. As a result, the quality of the optimization highly depends on
the precision of the model. Moreover, it requires accurate knowledge
of the saturation dependent machine inductances. Therefore, the
present contribution proposes a method to minimize the overall losses
of a salient pole EESM and its inverter in steady state operation based
on measurement data only. Since this method does not require any
manufacturer data, it is well suited for an automated measurement
data evaluation and inverter parametrization. The field oriented control
(FOC) of an EESM provides three current components resp. three
degrees of freedom (DOF). An analytic minimization of the copper
losses in the stator and the rotor (assuming constant inductances) is
performed and serves as a first approximation of how to choose the
optimal current reference values. After a numeric offline minimization
of the overall losses based on measurement data the results are
compared to a control strategy that satisfies cos (ϕ) = 1.
Abstract: In this study, the effect of greywater irrigation on airwater interfacial area is investigated. Several soil column experiments were conducted for different greywater irrigation to develop the pressure-saturation curves. Surface tension was measured for different greywater concentration and fitted for Gibbs adsorption equation. Pressure-saturation curves show that the reduction of capillary rise stops when it reaches its critical micelle concentration (CMC). A simple theory is derived from pressure-saturation curves for calculating air-water interfacial area in porous medium during greywater irrigation by introducing a term 'hydraulic radius' for the pores. This term diminishes any effect of pore shapes on the air-water interfacial area. The air-water interfacial area was calculated using the pressure-saturation curves and found that it decreases with increasing moisture content. But no significant effect was observed on air-water interfacial area for different greywater irrigation. A maximum of 10% variation in interfacial area was observed at the residual saturation zone.
Abstract: The article presents a new method for detection of
artificial objects and materials from images of the environmental
(non-urban) terrain. Our approach uses the hue and saturation (or Cb
and Cr) components of the image as the input to the segmentation
module that uses the mean shift method. The clusters obtained as the
output of this stage have been processed by the decision-making
module in order to find the regions of the image with the significant
possibility of representing human. Although this method will detect
various non-natural objects, it is primarily intended and optimized for
detection of humans; i.e. for search and rescue purposes in non-urban
terrain where, in normal circumstances, non-natural objects shouldn-t
be present. Real world images are used for the evaluation of the
method.
Abstract: This study reports the preparation of soft magnetic ribbons of Fe-based amorphous alloys using the single-roller melt-spinning technique. Ribbon width varied from 142 mm to 213 mm and, with a thickness of approximately 22 μm 2 μm. The microstructure and magnetic properties of the ribbons were characterized by differential scanning calorimeter (DSC), X-ray diffraction (XRD), vibrating sample magnetometer (VSM), and electrical resistivity measurements (ERM). The amorphous material properties dependence of the cooling rate and nozzle pressure have uneven surface in ribbon thicknesses are investigated. Magnetic measurement results indicate that some region of the ribbon exhibits good magnetic properties, higher saturation induction and lower coercivity. However, due to the uneven surface of 213 mm wide ribbon, the magnetic responses are not uniformly distributed. To understand the transformer magnetic performances, this study analyzes the measurements of a three-phase 2 MVA amorphous-cored transformer. Experimental results confirm that the transformer with a ribbon width of 142 mm has better magnetic properties in terms of lower core loss, exciting power, and audible noise.
Abstract: Self-sensing estimates the air gap within an electro
magnetic path by analyzing the bearing coil current and/or voltage
waveform. The self-sensing concept presented in this paper has been
developed within the research project “Active Magnetic Bearings
with Supreme Reliability" and is used for position sensor fault
detection.
Within this new concept gap calculation is carried out by an alldigital
analysis of the digitized coil current and voltage waveform.
For analysis those time periods within the PWM period are used,
which give the best results. Additionally, the concept allows the
digital compensation of nonlinearities, for example magnetic
saturation, without degrading signal quality. This increases the
accuracy and robustness of the air gap estimation and additionally
reduces phase delays.
Beneath an overview about the developed concept first
measurement results are presented which show the potential of this
all-digital self-sensing concept.
Abstract: This paper presents the climatic range calculations for
comfort evaporative cooling for Tehran. In this study the minimum
climatic conditions required to achieve an appropriate comfort zone
will be presented.
Physiologically uncomfortable conditions in arid climates are
mainly caused by the extreme heat and dryness. Direct evaporative
cooling adds moisture to the air stream until the air stream is close to
saturation. The dry bulb temperature is reduced, while the wet bulb
temperature stays the same. Evaporative cooling is economical,
effective, environmentally friendly, and healthy.
Comfort cooling by direct evaporative cooling (passive or fan
forced) in the 35. 41 N (such as Tehran) latitude requires design
wet-bulb temperature not over 25.4 C. Evaporative cooling outside
this limit cannot achieve the required 26.7 ET, and is recommended
for relief cooling only.
Abstract: Gas condensate Reservoirs show complicated thermodynamic behavior when their pressure reduces to under dew point pressure. Condensate blockage around the producing well cause significant reduction of production rate as well bottom-hole pressure drops below saturation pressure. The main objective of this work was to examine the well test analysis of naturally fractured lean gas condensate reservoir and investigate the effect of condensate formed around the well-bore on behavior of single phase pseudo pressure and its derivative curves. In this work a naturally fractured lean gas condensate reservoir is simulated with compositional simulator. Different sensitivity analysis done on Corry parameters and result of simulator is feed to analytical well testing software. For consideration of these phenomena eighteen compositional models with Capillary number effect are constructed. Matrix relative permeability obeys Corry relative permeability and relative permeability in fracture is linear. Well testing behavior of these models are studied and interpreted. Results show different sensitivity analysis on relative permeability of matrix does not have strong effect on well testing behavior even most part of the matrix around the well is occupied with condensate.
Abstract: A multivariable discontinuous feedback linearization approach is proposed to position control of an electrically driven fast robot manipulator. A desired performance is achieved by selecting a useful controller and suitable sampling rate and considering saturation for actuators. There is a high flexibility to apply the proposed control approach on different electrically driven manipulators. The control approach can guarantee the stability and satisfactory tracking performance. A PUMA 560 robot driven by geared permanent magnet dc motors is simulated. The simulation results show a desired performance for control system under technical specifications.
Abstract: In a wireless communication system, a
predistorter(PD) is often employed to alleviate nonlinear distortions
due to operating a power amplifier near saturation, thereby improving
the system performance and reducing the interference to adjacent
channels. This paper presents a new adaptive polynomial digital
predistorter(DPD). The proposed DPD uses Coordinate Rotation
Digital Computing(CORDIC) processors and PD process by pipelined
architecture. It is simpler and faster than conventional adaptive
polynomial DPD. The performance of the proposed DPD is proved by
MATLAB simulation.
Abstract: Differentiated impact of team sports (basketball, indoor soccer, handball) on general haemodynamics and aerobic potential of students who specialize in technical subjects is detected only on the fourth year of studies in the institute of higher education. Those who play basketball and indoor soccer have shown increase of stroke and minute volume of blood indices, pumping and contractile function of the heart, oxygenation of blood and oxygen delivery to tissues, aerobic energy supply and balance of sympathetic and parasympathetic activity of the nervous regulation mechanism of the circulatory system. Those who play handball have shown these indices statistically decreased. On the whole playing basketball and indoor soccer optimizes the strategy for adaptation of students to the studying process, but playing handball does the opposite thing. The leading factor for adaptation of students is: those who play basketball have increase of minute blood volume which stipulates velocity of the system blood circulation and well-timed oxygen delivery to tissues; those who play indoor soccer have increase of power and velocity of contractile function of the heart; those who play handball have increase of resistance of thorax to the system blood flow which minimizes contractile function of the heart, blood oxygen saturation and delivery of oxygen to tissues.
Abstract: KREISIG is a computer simulation program, firstly developed by Munawar (1994) in Germany to optimize signalized roundabout. The traffic movement is based on the car following theory. Turbine method has been implemented for signal setting. The program has then been further developed in Indonesia to meet the traffic characteristics in Indonesia by adjusting the sensitivity of the drivers. Trial and error method has been implemented to adjust the saturation flow. The saturation flow output has also been compared to the calculation method according to 1997 Indonesian Highway Capacity Manual. It has then been implemented to optimize signalized roundabout at Kleringan roundabout in Malioboro area, Yogyakarta, Indonesia. It is found that this method can optimize the signal setting of this roundabout. Therefore, it is recommended to use this program to optimize signalized roundabout.
Abstract: A new technique based on Pattern search optimization is proposed for estimating different solar cell parameters in this paper. The estimated parameters are the generated photocurrent, saturation current, series resistance, shunt resistance, and ideality factor. The proposed approach is tested and validated using double diode model to show its potential. Performance of the developed approach is quite interesting which signifies its potential as a promising estimation tool.
Abstract: This paper presents a new approach for busbar protection with stable operation of current transformer during saturation, using fuzzy neuro and symmetrical components theory. This technique uses symmetrical components of current signals to learn the hidden relationship existing in the input patterns. Simulation studies are preformed and the influence of changing system parameters such as inception fault and source impedance is studied. Details of the design procedure and the results of performance studies with the proposed relay are given in the paper. An analysis of the performance of the proposed technique during ct saturation conditions is presented. The performance of the technique was investigated for a variety of operating conditions and for several busbar configurations. Data generated by EMTDC simulations of model power systems were used in the investigations. The results indicate that the proposed technique is stable during ct saturation conditions.