Abstract: An experimental study on finned-tube radiators has been conducted. Three radiators found in desktop computers sized for 120 mm fans were tested in steady and pulsatile flows of ambient air over a Reynolds number range of 50 < Re < 900. Water at 60 °C was circulated through the radiators to maintain a constant fin temperature during the tests. For steady flow, it was found that the heat transfer rate increased linearly with the mass flow rate of air. The pulsatile flow experiments showed that frequency of pulsation had a negligible effect on the heat transfer rate for the range of frequencies tested (0.5 Hz – 2.5 Hz). For all three radiators, the heat transfer rate was decreased in the case of pulsatile flow. Linear heat transfer correlations for steady and pulsatile flow were calculated in terms of Reynolds number and Nusselt number.
Abstract: In all industries which are related to heat, suitable
thermal ranges are defined for each device to operate well.
Consideration of these limits requires a thermal control unit beside
the main system. The Satellite Thermal Control Unit exploits from
different methods and facilities individually or mixed. For enhancing
heat transfer between primary surface and the environment,
utilization of radiating extended surfaces are common. Especially for
large temperature differences; variable thermal conductivity has a
strong effect on performance of such a surface .In most literatures,
thermo-physical properties, such as thermal conductivity, are
assumed as constant. However, in some recent researches the
variation of these parameters is considered. This may be helpful for
the evaluation of fin-s temperature distribution in relatively large
temperature differences. A new method is introduced to evaluate
temperature-dependent thermal conductivity values. The finite
volume method is employed to simulate numerically the temperature
distribution in a space radiating fin. The present modeling is carried
out for Aluminum as fin material and compared with previous
method. The present results are also compared with those of two
other analytical methods and good agreement is shown.
Abstract: Manufacturing components of fiber-reinforced
thermoplastics requires three steps: heating the matrix, forming and
consolidation of the composite and terminal cooling the matrix. For
the heating process a pre-determined temperature distribution through
the layers and the thickness of the pre-consolidated sheets is
recommended to enable forming mechanism. Thus, a design for the
heating process for forming composites with thermoplastic matrices
is necessary. To obtain a constant temperature through thickness and
width of the sheet, the heating process was analyzed by the help of
the finite element method. The simulation models were validated by
experiments with resistance thermometers as well as with an infrared
camera. Based on the finite element simulation, heating methods for
infrared radiators have been developed. Using the numeric
simulation many iteration loops are required to determine the process
parameters. Hence, the initiation of a model for calculating relevant
process parameters started applying regression functions.
Abstract: To simulate heating systems in buildings, a research oriented computer code has been developed in Sharif University of Technology in Iran where the climate, existing heating equipment in buildings, consumer behavior and their interactions are considered for simulating energy consumption in conventional systems such as heaters, radiators and fan-coils. In order to validate the computer code, the available data of five buildings was used and the computed consumed energy was compared with the estimated energy extracted from monthly bills. The initial heating system was replaced by the alternative system and the effect of this change was observed on the energy consumption. As a result, the effect of changing heating equipment on energy consumption was investigated in different climates. Changing heater to radiator renders energy conservation up to 50% in all climates and changing radiator to fan-coil decreases energy consumption in climates with cold and dry winter.
Abstract: TUSAT is a prospective Turkish
Communication Satellite designed for providing mainly data
communication and broadcasting services through Ku-Band
and C-Band channels. Thermal control is a vital issue in
satellite design process. Therefore, all satellite subsystems and
equipments should be maintained in the desired temperature
range from launch to end of maneuvering life. The main
function of the thermal control is to keep the equipments and
the satellite structures in a given temperature range for various
phases and operating modes of spacecraft during its lifetime.
This paper describes the thermal control design which uses
passive and active thermal control concepts. The active
thermal control is based on heaters regulated by software via
thermistors. Alternatively passive thermal control composes of
heat pipes, multilayer insulation (MLI) blankets, radiators,
paints and surface finishes maintaining temperature level of
the overall carrier components within an acceptable value.
Thermal control design is supported by thermal analysis using
thermal mathematical models (TMM).
Abstract: To simulate heating systems in buildings, a research oriented computer code has been developed in Sharif University of Technology in Iran where the climate, existing heating equipment in buildings, consumer behavior and their interactions are considered for simulating energy consumption in conventional systems such as heaters, radiators and fan-coils. In order to validate the computer code, the available data of five buildings was used and the computed consumed energy was compared with the estimated energy extracted from monthly bills. The initial heating system was replaced by the alternative system and the effect of this change was observed on the energy consumption. As a result, the effect of changing heating equipment on energy consumption was investigated in different climates. Changing heater to radiator renders energy conservation up to 50% in all climates and changing radiator to fan-coil decreases energy consumption in climates with cold and dry winter.