Abstract: Recently, graphene has gained much attention because of its unique optical, mechanical, electrical, and thermal properties. Graphene has been used as a key material in the technological applications in various areas such as sensors, drug delivery, super capacitors, transparent conductor, and solar cell. It has a superior quenching efficiency for various fluorophores. Based on these unique properties, the optical sensors with graphene materials as the energy acceptors have demonstrated great success in recent years. During quenching, the emission of a fluorophore is perturbed by a quencher which can be a substrate or biomolecule, and due to this phenomenon, fluorophore-quencher has been used for selective detection of target molecules. Among fluorescence dyes, 1,8-naphthalimide is well known for its typical intramolecular charge transfer (ICT) and photo-induced charge transfer (PET) fluorophore, strong absorption and emission in the visible region, high photo stability, and large Stokes shift. Derivatives of 1,8-naphthalimides have found applications in some areas, especially fluorescence sensors. Herein, the fluorescence quenching of graphene oxide has been carried out on a naphthalimide dye as a fluorescent probe model. The quenching ability of graphene oxide on naphthalimide dye was studied by UV-VIS and fluorescence spectroscopy. This study showed that graphene is an efficient quencher for fluorescent dyes. Therefore, it can be used as a suitable candidate sensing platform. To the best of our knowledge, studies on the quenching and absorption of naphthalimide dyes by graphene oxide are rare.
Abstract: This paper is about the development of non-invasive heart rate and oxygen saturation in human blood using Altera NIOS II soft-core processor system. In today's world, monitoring oxygen saturation and heart rate is very important in hospitals to keep track of low oxygen levels in blood. We have designed an Embedded System On Peripheral Chip (SOPC) reconfigurable system by interfacing two LED’s of different wavelengths (660 nm/940 nm) with a single photo-detector to measure the absorptions of hemoglobin species at different wavelengths. The implementation of the interface with Finger Probe and Liquid Crystal Display (LCD) was carried out using NIOS II soft-core system running on Altera NANO DE0 board having target as Cyclone IVE. This designed system is used to monitor oxygen saturation in blood and heart rate for different test subjects. The designed NIOS II processor based non-invasive heart rate and oxygen saturation was verified with another Operon Pulse oximeter for 50 measurements on 10 different subjects. It was found that the readings taken were very close to the Operon Pulse oximeter.
Abstract: The addition of PEG of different molecular weights has important effects on the physical, electrical and electrochemical properties of iron(III)-tosylate doped PEDOT. This particular polymer can be easily spin coated over plastic discs, optimizing thickness and uniformity of the PEDOT-PEG films. The conductivity and morphological analysis of the hybrid PEDOT-PEG polymer by 4-point probe (4PP), 12-point probe (12PP), and conductive AFM (C-AFM) show strong effects of the PEG doping. Moreover, the conductive films kinetics at the nanoscale, in response to different bias voltages, change radically depending on the PEG molecular weight. The hybrid conductive films show also interesting electrochemical properties, making the PEDOT PEG doping appealing for biosensing applications both for EIS-based and amperometric affinity/catalytic biosensors.
Abstract: The American English contrast /ɑ-ʌ/ (cop-cup) is difficult to be produced by Italian learners since they realize L2-/ɑ-ʌ/ as L1-/ɔ-a/ respectively, due to differences in phonetic-phonological systems and also in grapheme-to-phoneme conversion rules. In this paper, we try to answer the following research questions: Can a short training improve the production of English /ɑ-ʌ/ by Italian learners? Is a perceptual training better than an articulatory (ultrasound - US) training? Thus, we compare a perceptual training with an US articulatory one to observe: 1) the effects of short trainings on L2-/ɑ-ʌ/ productions; 2) if the US articulatory training improves the pronunciation better than the perceptual training. In this pilot study, 9 Salento-Italian monolingual adults participated: 3 subjects performed a 1-hour perceptual training (ES-P); 3 subjects performed a 1-hour US training (ES-US); and 3 control subjects did not receive any training (CS). Verbal instructions about the phonetic properties of L2-/ɑ-ʌ/ and L1-/ɔ-a/ and their differences (representation on F1-F2 plane) were provided during both trainings. After these instructions, the ES-P group performed an identification training based on the High Variability Phonetic Training procedure, while the ES-US group performed the articulatory training, by means of US video of tongue gestures in L2-/ɑ-ʌ/ production and dynamic view of their own tongue movements and position using a probe under their chin. The acoustic data were analyzed and the first three formants were calculated. Independent t-tests were run to compare: 1) /ɑ-ʌ/ in pre- vs. post-test respectively; /ɑ-ʌ/ in pre- and post-test vs. L1-/a-ɔ/ respectively. Results show that in the pre-test all speakers realize L2-/ɑ-ʌ/ as L1-/ɔ-a/ respectively. Contrary to CS and ES-P groups, the ES-US group in the post-test differentiates the L2 vowels from those produced in the pre-test as well as from the L1 vowels, although only one ES-US subject produces both L2 vowels accurately. The articulatory training seems more effective than the perceptual one since it favors the production of vowels in the correct direction of L2 vowels and differently from the similar L1 vowels.
Abstract: Photoacoustic Tomography (PAT) is a promising medical imaging modality that combines optical imaging contrast with the spatial resolution of ultrasound imaging. It can also distinguish the changes in biological features. But, real-time PAT system should be confirmed due to photoacoustic effect for tissue. Thus, we have developed a real-time PAT system using a custom-developed data acquisition board and ultrasound linear probe. To evaluate performance of our system, phantom test was performed. As a result of those experiments, the system showed satisfactory performance and its usefulness has been confirmed. We monitored the degradation of inflammation which induced on the rat’s kidney using real-time PAT.
Abstract: This study aimed at developing an inverse heat transfer approach for predicting the time-varying freezing front and the temperature distribution of tumors during cryosurgery. Using a temperature probe pressed against the layer of tumor, the inverse approach is able to predict simultaneously the metabolic heat generation and the blood perfusion rate of the tumor. Once these parameters are predicted, the temperature-field and time-varying freezing fronts are determined with the direct model. The direct model rests on one-dimensional Pennes bioheat equation. The phase change problem is handled with the enthalpy method. The Levenberg-Marquardt Method (LMM) combined to the Broyden Method (BM) is used to solve the inverse model. The effect (a) of the thermal properties of the diseased tissues; (b) of the initial guesses for the unknown thermal properties; (c) of the data capture frequency; and (d) of the noise on the recorded temperatures is examined. It is shown that the proposed inverse approach remains accurate for all the cases investigated.
Abstract: Redundancy requirements for UAV (Unmanned Aerial
Vehicle) are hardly faced due to the generally restricted amount
of available space and allowable weight for the aircraft systems,
limiting their exploitation. Essential equipment as the Air Data,
Attitude and Heading Reference Systems (ADAHRS) require several
external probes to measure significant data as the Angle of Attack
or the Sideslip Angle. Previous research focused on the analysis
of a patented technology named Smart-ADAHRS (Smart Air Data,
Attitude and Heading Reference System) as an alternative method to
obtain reliable and accurate estimates of the aerodynamic angles.
This solution is based on an innovative sensor fusion algorithm
implementing soft computing techniques and it allows to obtain a
simplified inertial and air data system reducing external devices.
In fact, only one external source of dynamic and static pressures
is needed. This paper focuses on the benefits which would be
gained by the implementation of this system in UAV applications.
A simplification of the entire ADAHRS architecture will bring to
reduce the overall cost together with improved safety performance.
Smart-ADAHRS has currently reached Technology Readiness Level
(TRL) 6. Real flight tests took place on ultralight aircraft equipped
with a suitable Flight Test Instrumentation (FTI). The output of
the algorithm using the flight test measurements demonstrates the
capability for this fusion algorithm to embed in a single device
multiple physical and virtual sensors. Any source of dynamic and
static pressure can be integrated with this system gaining a significant
improvement in terms of versatility.
Abstract: We investigate the influence of annealing on the properties of a contact between graphene and metal (Au and Ni), using circular transmission line model (CTLM) contact geometry. Kelvin probe force microscopy (KPFM) and Raman spectroscopy are applied for characterization of the surface and interface properties. Annealing causes a decrease of the metal-graphene contact resistance for both Ni and Au.
Abstract: Beam-column connections play an important role in the reinforced concrete moment resisting frame (RCMRF), which is one of the most commonly used structural systems around the world. The premature failure of such connections would severely limit the seismic performance and increase the vulnerability of RCMRF. In the past decades, researchers primarily focused on investigating the structural behaviour and failure mechanisms of conventional beam-column joints, the beam width of which is either smaller than or equal to the column width, while studies in wide beam-column joints were scarce. This paper presents the preliminary experimental results of two full-scale exterior wide beam-column connections, which are mainly designed and detailed according to ACI 318-14 and ACI 352R-02, under reversed cyclic loading. The ratios of the design shear force to the nominal shear strength of these specimens are 1.0 and 1.7, respectively, so as to probe into differences of the joint shear strength between experimental results and predictions by design codes of practice. Flexural failure dominated in the specimen with ratio of 1.0 in which full-width plastic hinges were observed, while both beam hinges and post-peak joint shear failure occurred for the other specimen. No sign of premature joint shear failure was found which is inconsistent with ACI codes’ prediction. Finally, a modification of current codes of practice is provided to accurately predict the joint shear strength in wide beam-column joint.
Abstract: A 3C-2D PIV technique was applied to investigate the swirling flow generated by an axial plus tangential type swirl generator. This work is focused on the near-exit region of an isothermal swirling jet to characterize the effect of swirl on the flow field and to identify the large coherent structures both in unconfined and confined conditions for geometrical swirl number, Sg = 4.6. Effects of the Reynolds number on the flow structure were also studied. The experimental results show significant effects of the confinement on the mean velocity fields and its fluctuations. The size of the recirculation zone was significantly enlarged upon confinement compared to the free swirling jet. Increasing in the Reynolds number further enhanced the recirculation zone. The frequency characteristics have been measured with a capacitive microphone which indicates the presence of periodic oscillation related to the existence of precessing vortex core, PVC. Proper orthogonal decomposition of the jet velocity field was carried out, enabling the identification of coherent structures. The time coefficients of the first two most energetic POD modes were used to reconstruct the phase-averaged velocity field of the oscillatory motion in the swirling flow. The instantaneous minima of negative swirl strength values calculated from the instantaneous velocity field revealed the presence of two helical structures located in the inner and outer shear layers and this structure fade out at an axial location of approximately z/D = 1.5 for unconfined case and z/D = 1.2 for confined case. By phase averaging the instantaneous swirling strength maps, the 3D helical vortex structure was reconstructed.
Abstract: Well-defined 2D Eu+3 co-doped ZrO2: Gd+3 nanoparticles were successfully synthesized by microwave assisted solution combustion technique for luminescent applications. The present investigation reports the rapid and effective method for the synthesis of the Eu+3 co-doped ZrO2:Gd+3 nanoparticles and study of the luminescence behavior of Eu+3 ion in ZrO2:Gd+3 nanostructures. The optical properties of the prepared nanostructures were investigated by using UV-visible spectroscopy and photoluminescence spectra. The phase formation and the morphology of the nanoplatelets were studied by XRD, FESEM and HRTEM. The average grain size was found to be 45-50 nm. The presence of Gd3+ ion increases the crystallinity of the material and hence acts as a good nucleating agent. The ZrO2:Gd3+ co-doped with Eu+3 nanoplatelets gives an emission at 607 nm, a strong red emission under the excitation wavelength of 255 nm.
Abstract: We report in this paper the design and qualification of a cylindrical unbalanced magnetron source. The dedicated magnetic assemblies were simulated using a finite element model. A hall-effect magnetic probe was then used to characterize those assemblies and compared to the theoretical magnetic profiles. These show a good agreement between the expected and actual values. The qualification of the different magnetic assemblies was then performed by measuring the ion flux density reaching the surface of the sample to be coated using a commercial retarding field energy analyzer. The strongest unbalanced configuration shows an increase from 0.016 A.cm-2 to 0.074 A.cm-2 of the ion flux density reaching the sample surface compared to the standard balanced configuration for a pressure 5.10-3 mbar and a plasma source power of 300 W.
Abstract: A compact method for measuring the relative permittivity of a dielectric material at different temperatures using a single circular Split Ring Resonator (SRR) metamaterial unit working as a test probe is presented in this paper. The dielectric constant of a material is dependent upon its temperature and the LC resonance of the SRR depends on its dielectric environment. Hence, the temperature of the dielectric material in contact with the resonator influences its resonant frequency. A single SRR placed between transmitting and receiving probes connected to a Vector Network Analyser (VNA) is used as a test probe. The dependence of temperature between 30 oC and 60 oC on resonant frequency of SRR is analysed. Relative permittivities ‘ε’ of test samples for different temperatures are extracted from a calibration graph drawn between the relative permittivity of samples of known dielectric constant and their corresponding resonant frequencies. This method is found to be an easy and efficient technique for analysing the temperature dependent permittivity of different materials.
Abstract: The present experimental study insights the decontamination of instantaneous velocity fluctuations captured by Acoustic Doppler Velocimeter (ADV) in gravel-bed streams to ascertain near-bed turbulence for low Reynolds number. The interference between incidental and reflected pulses produce spikes in the ADV data especially in the near-bed flow zone and therefore filtering the data are very essential. Nortek’s Vectrino four-receiver ADV probe was used to capture the instantaneous three-dimensional velocity fluctuations over a non-cohesive bed. A spike removal algorithm based on the acceleration threshold method was applied to note the bed roughness and its influence on velocity fluctuations and velocity power spectra in the carrier fluid. The velocity power spectra of despiked signals with a best combination of velocity threshold (VT) and acceleration threshold (AT) are proposed which ascertained velocity power spectra a satisfactory fit with the Kolmogorov “–5/3 scaling-law” in the inertial sub-range. Also, velocity distributions below the roughness crest level fairly follows a third-degree polynomial series.
Abstract: The GERmanium Detector Array (GERDA) experiment,
located at the Laboratori Nazionali del Gran Sasso (LNGS) of
INFN, searches for 0νββ of 76Ge. Germanium diodes enriched to
∼ 86 % in the double beta emitter 76Ge(enrGe) are exposed being
both source and detectors of 0νββ decay. Neutrinoless double beta
decay is considered a powerful probe to address still open issues
in the neutrino sector of the (beyond) Standard Model of particle
Physics. Since 2013, just after the completion of the first part of its
experimental program (Phase I), the GERDA setup has been upgraded
to perform its next step in the 0νββ searches (Phase II). Phase II aims
to reach a sensitivity to the 0νββ decay half-life larger than 1026 yr
in about 3 years of physics data taking. This exposing a detector
mass of about 35 kg of enrGe and with a background index of about
10^−3 cts/(keV·kg·yr). One of the main new implementations is the
liquid argon scintillation light read-out, to veto those events that only
partially deposit their energy both in Ge and in the surrounding LAr.
In this paper, the GERDA Phase II expected goals, the upgrade work
and few selected features from the 2015 commissioning and 2016
calibration runs will be presented. The main Phase I achievements
will be also reviewed.
Abstract: A novel sensing system has been designed for
naphthalene detection based on the quenched fluorescence signal of
CdS quantum dots. The fluorescence intensity of the system reduced
significantly after adding CdS quantum dots to the water pollution
model because of the fluorescent static quenching f mechanism.
Herein, we have demonstrated the facile methodology can offer a
convenient and low analysis cost with the recovery rate as
97.43%-103.2%, which has potential application prospect.
Abstract: This work studies the effect of thickness on structural
and electrical properties of CuAlS2 thin films grown by two stage
vacuum thermal evaporation technique. CuAlS2 thin films of
thicknesses 50nm, 100nm and 200nm were deposited on suitably
cleaned corning 7059 glass substrate at room temperature (RT). In
the first stage Cu-Al precursors were grown at room temperature by
thermal evaporation and in the second stage Cu-Al precursors were
converted to CuAlS2 thin films by sulfurisation under sulfur
atmosphere at the temperature of 673K. The structural properties of
the films were examined by X-ray diffraction (XRD) technique while
electrical properties of the specimens were studied using four point
probe method. The XRD studies revealed that the films are of
crystalline in nature having tetragonal structure. The variations of the
micro-structural parameters, such as crystallite size (D), dislocation
density ( ), and micro-strain ( ), with film thickness were
investigated. The results showed that the crystallite sizes increase as
the thickness of the film increases. The dislocation density and
micro-strain decreases as the thickness increases. The resistivity ( )
of CuAlS2 film is found to decrease with increase in film thickness,
which is related to the increase of carrier concentration with film
thickness. Thus thicker films exhibit the lowest resistivity and high
carrier concentration, implying these are the most conductive films.
Low electrical resistivity and high carrier concentration are widely
used as the essential components in various optoelectronic devices
such as light-emitting diode and photovoltaic cells.
Abstract: Production fluids are transported from the platform to
tankers or process facilities through transfer pipelines. Water being
one of the heavier phases tends to settle at the bottom of pipelines
especially at low flow velocities and this has adverse consequences
for pipeline integrity. On restart after a shutdown, this could result in
corrosion and issues for process equipment, thus the need to have the
heavier liquid dispersed into the flowing lighter fluid. This study
looked at the flow regime of low water cut and low flow velocity oil
and water flow using conductive film thickness probes in a large
diameter 4-inch pipe to obtain oil and water interface height and the
interface structural velocity. A wide range of 0.1–1.0 m/s oil and
water mixture velocities was investigated for 0.5–5% water cut. Two
fluid model predictions were used to compare with the experimental
results.
Abstract: In this paper, we calculate the two-photon ionization
(TPI) cross-section for pump-probe scheme in Ag neutral cluster. The
pump photon energy is assumed to be close to the surface plasmon
(SP) energy of cluster in dielectric media. Due to this choice, the
pump wave excites collective oscillations of electrons-SP and the
probe wave causes ionization of the cluster. Since the interband
transition energy in Ag exceeds the SP resonance energy, the main
contribution into the TPI comes from the latter. The advantage of Ag
clusters as compared to the other noble metals is that the SP
resonance in silver cluster is much sharper because of peculiarities of
its dielectric function. The calculations are performed by separating
the coordinates of electrons corresponding to the collective
oscillations and the individual motion that allows taking into account
the resonance contribution of excited SP oscillations. It is shown that
the ionization cross section increases by two orders of magnitude if
the energy of the pump photon matches the surface plasmon energy
in the cluster.
Abstract: This paper describes the development of a DNA-based
nanobiosensor to detect the dengue virus in mosquito using
electrically active magnetic (EAM) nanoparticles as concentrator and
electrochemical transducer. The biosensor detection encompasses
two sets of oligonucleotide probes that are specific to the dengue
virus: the detector probe labeled with the EAM nanoparticles and the
biotinylated capture probe. The DNA targets are double hybridized to
the detector and the capture probes and concentrated from
nonspecific DNA fragments by applying a magnetic field.
Subsequently, the DNA sandwiched targets (EAM-detector probe–
DNA target–capture probe-biotin) are captured on streptavidin
modified screen printed carbon electrodes through the biotinylated
capture probes. Detection is achieved electrochemically by measuring
the oxidation–reduction signal of the EAM nanoparticles. Results
indicate that the biosensor is able to detect the redox signal of the
EAM nanoparticles at dengue DNA concentrations as low as 10
ng/μl.