Abstract: For many years, the ear protectors have been used to preventing the audio and non-audio effects of received noise from occupation environments. Despite performing hearing protection programs, there are many people which still suffer from noise-induced hearing loss. This study was conducted with the aim of determination of human hearing system response to received noise and the effectiveness of ear protectors on preventing of noise-induced hearing loss. Sound pressure microphones were placed in a simulated ear canal. The severity of noise measured inside and outside of ear canal. The noise reduction values due to installing ear protectors were calculated in the octave band frequencies and LabVIEW programmer. The results of noise measurement inside and outside of ear canal showed a different in received sound levels by ear canal. The effectiveness of ear protectors has been considerably reduced for the low frequency limits. A change in resonance frequency also was observed after using ear protectors. The study indicated the ear canal structure may affect the received noise and it may lead a difference between the received sound from the measured sound by a sound level meter, and hearing system. It means the human hearing system may probably respond different from a sound level meter. Hearing protectors’ efficiency declines by increasing the noise levels, and thus, they are not suitable to protect workers against industrial noise particularly low frequency noise. Hearing protectors may be solely a reason to damaging of hearing system in a special frequency via changing of human hearing system acoustical structure. We need developing the subjective method of hearing protectors testing, because their evaluation is not designed based on industrial noise or in the field.
Abstract: In this research, a quantitative assessment of the urban sound environment of the city of Biskra, Algeria, was conducted. To determine the quality of the soundscape based on in-situ measurement, using a Landtek SL5868P sound level meter in 47 points, which have been identified to represent the whole city. The result shows that the urban noise level varies from 55.3 dB to 75.8 dB during the weekdays and from 51.7 dB to 74.3 dB during the weekend. On the other hand, we can also note that 70.20% of the results of the weekday measurements and 55.30% of the results of the weekend measurements have levels of sound intensity that exceed the levels allowed by Algerian law and the recommendations of the World Health Organization. These very high urban noise levels affect the quality of life, the acoustic comfort and may even pose multiple risks to people's health.
Abstract: During the last few decades, the continuously increasing demand for accurate and reliable magnetic measurements has paved the way for the development of different types of magnetic sensing systems as well as different measurement techniques. Sensor sensitivity and linearity, signal-to-noise ratio, measurement range, cross-talk between sensors in multi-sensor applications are only some of the aspects that have been examined in the past. In this paper, a fully analog closed loop system in order to optimize the performance of AMR sensors has been developed. The operation of the proposed system has been tested using a Helmholtz coil calibration setup in order to control both the amplitude and direction of magnetic field in the vicinity of the AMR sensor. Experimental testing indicated that improved linearity of sensor response, as well as low noise levels can be achieved, when the system is employed.
Abstract: A technique for estimating the direction-of-arrival (DOA) of unknown number of source signals is presented using the eigen-approach. The eigenvector corresponding to the minimum eigenvalue of the autocorrelation matrix yields the minimum output power of the array. Also, the array polynomial with this eigenvector possesses roots on the unit circle. Therefore, the pseudo-spectrum is found by perturbing the phases of the roots one by one and calculating the corresponding array output power. The results indicate that the DOAs and the number of source signals are estimated accurately in the presence of a wide range of input noise levels.
Abstract: Image enhancement is a challenging issue in many applications. In the last two decades, there are various filters developed. This paper proposes a novel method which removes Gaussian noise from the gray scale images. The proposed technique is compared with Enhanced Fuzzy Peer Group Filter (EFPGF) for various noise levels. Experimental results proved that the proposed filter achieves better Peak-Signal-to-Noise-Ratio PSNR than the existing techniques. The proposed technique achieves 1.736dB gain in PSNR than the EFPGF technique.
Abstract: With increasing number of wireless devices like
laptops, Wi-Fi Web Cams, network extenders, etc., a new kind of
problems appeared, mostly related to poor Wi-Fi throughput or
communication problems. In this paper an investigation on wireless
networks and it-s saturation in Vilnius City and its surrounding is
presented, covering the main problems of wireless saturation and
network load during day. Also an investigation on wireless channel
selection and noise levels were made, showing the impact of
neighbor AP to signal and noise levels and how it changes during the
day.
Abstract: Whit the increasing of traffic, noise emanated from
motor vehicles increases as well, which subsequently causes adding
to the stress of modern city. Thus, it is needed to look for most
critical areas in terms of environmental and social impact of noise.
There are several critical situations for noise emanated from motor
vehicles such as stop and go situation which usually occurs near
junctions or at-grade intersections. This study was conducted in two
locations, most common types of intersections, crossroads and Tjunctions.
The highest average noise levels are recorded during Go
phase for T-junction, 64.4 dB, and Drive phase for crossroad, 64 dB.
It implies that the existence of intersection caused the noise level to
increase. The vehicles starting to move produce more sound than
when they travel at a constant speed along the intersection. It is
suggested that special considerations and priority of allocating funds
should be given to these critical spots.
Abstract: The impact of noise upon live quality has become an
important aspect to make both urban and environmental policythroughout
Europe and in Turkey. Concern over the quality of urban
environments, including noise levels and declining quality of green
space, is over the past decade with increasing emphasis on designing
livable and sustainable communities. According to the World Health
Organization, noise pollution is the third most hazardous
environmental type of pollution which proceeded by only air (gas
emission) and water pollution. The research carried out in two
phases, the first stage of the research noise and plant types providing
the suction of noise was evaluated through literature study and at the
second stage, definite types (Juniperus horizontalis L., Spirea
vanhouetti Briot., Cotoneaster dammerii C.K., Berberis thunbergii
D.C., Pyracantha coccinea M. etc.) were selected for the city of
Konya. Trials were conducted on the highway of Konya. The biggest
value of noise reduction was 6.3 dB(A), 4.9 dB(A), 6.2 dB(A) value
with compared to the control which includes the group that formed
by the bushes at the distance of 7m, 11m, 20m from the source and
5m, 9m, 20m of plant width, respectively. In this paper, definitions
regarding to noise and its sources were made and the precautions
were taken against to noise that mentioned earlier with the adverse
effects of noise. Plantation design approaches and suggestions
concerning to the diversity to be used, which are peculiar to roadside,
were developed to discuss the role and the function of plant material
to reduce the noise of the traffic.
Abstract: Noise level has critical effects on the diagnostic
performance of signal-averaged electrocardiogram (SAECG), because
the true starting and end points of QRS complex would be masked by
the residual noise and sensitive to the noise level. Several studies and
commercial machines have used a fixed number of heart beats
(typically between 200 to 600 beats) or set a predefined noise level
(typically between 0.3 to 1.0 μV) in each X, Y and Z lead to perform
SAECG analysis. However different criteria or methods used to
perform SAECG would cause the discrepancies of the noise levels
among study subjects. According to the recommendations of 1991
ESC, AHA and ACC Task Force Consensus Document for the use of
SAECG, the determinations of onset and offset are related closely to
the mean and standard deviation of noise sample. Hence this study
would try to perform SAECG using consistent root-mean-square
(RMS) noise levels among study subjects and analyze the noise level
effects on SAECG. This study would also evaluate the differences
between normal subjects and chronic renal failure (CRF) patients in
the time-domain SAECG parameters.
The study subjects were composed of 50 normal Taiwanese and 20
CRF patients. During the signal-averaged processing, different RMS
noise levels were adjusted to evaluate their effects on three time
domain parameters (1) filtered total QRS duration (fQRSD), (2) RMS
voltage of the last QRS 40 ms (RMS40), and (3) duration of the low
amplitude signals below 40 μV (LAS40). The study results
demonstrated that the reduction of RMS noise level can increase
fQRSD and LAS40 and decrease the RMS40, and can further increase
the differences of fQRSD and RMS40 between normal subjects and
CRF patients. The SAECG may also become abnormal due to the
reduction of RMS noise level. In conclusion, it is essential to establish
diagnostic criteria of SAECG using consistent RMS noise levels for
the reduction of the noise level effects.
Abstract: In this paper, the noise maps for the area encircled by
the Second Ring Road in Riyadh city are developed based on real
measured data. Sound level meters, GPS receivers to determine
measurement position, a database program to manage the measured
data, and a program to develop the maps are used. A baseline noise
level has been established at each short-term site so subsequent
monitoring may be conducted to describe changes in Riyadh-s noise
environment. Short-term sites are used to show typical daytime and
nighttime noise levels at specific locations by short duration grab
sampling.
Abstract: Noise has adverse effect on human health and
comfort. Noise not only cause hearing impairment, but it also acts as
a causal factor for stress and raising systolic pressure. Additionally it
can be a causal factor in work accidents, both by marking hazards
and warning signals and by impeding concentration. Industry
workers also suffer psychological and physical stress as well as
hearing loss due to industrial noise. This paper proposes an approach
to enable engineers to point out quantitatively the noisiest source for
modification, while multiple machines are operating simultaneously.
The model with the point source and spherical radiation in a free field
was adopted to formulate the problem. The procedure works very
well in ideal cases (point source and free field). However, most of the
industrial noise problems are complicated by the fact that the noise is
confined in a room. Reflections from the walls, floor, ceiling, and
equipment in a room create a reverberant sound field that alters the
sound wave characteristics from those for the free field. So the model
was validated for relatively low absorption room at NIT Kurukshetra
Central Workshop. The results of validation pointed out that the
estimated sound power of noise sources under simultaneous
conditions were on lower side, within the error limits 3.56 - 6.35 %.
Thus suggesting the use of this methodology for practical
implementation in industry. To demonstrate the application of the
above analytical procedure for estimating the sound power of noise
sources under simultaneous operating conditions, a manufacturing
facility (Railway Workshop at Yamunanagar, India) having five
sound sources (machines) on its workshop floor is considered in this
study. The findings of the case study had identified the two most
effective candidates (noise sources) for noise control in the Railway
Workshop Yamunanagar, India. The study suggests that the
modification in the design and/or replacement of these two identified
noisiest sources (machine) would be necessary so as to achieve an
effective reduction in noise levels. Further, the estimated data allows
engineers to better understand the noise situations of the workplace
and to revise the map when changes occur in noise level due to a
workplace re-layout.
Abstract: The aim of this study was to determine noise level of
six different types of machines in printing companies in Novi Sad.
The A-weighted levels on Leq, Lmax and Lmin Sound Pressure Level
(SPL) in dBA were measured. It was found that the folders, offset
printing presses and binding machines are the predominant noise
sources. The noise levels produced by 12 of 38 machines exceed the
limiting threshold level of 85 dBA, tolerated by law. Since it was
determined that the average noise level for folders (87.7 dB) exceeds
the permitted value the octave analysis of noise was performed.