Abstract: Interest in using bacteria in cement materials due to its positive influences has been increased. Cement materials such as mortar and concrete basically suffer from higher porosity and water absorption compared to other building materials such as steel materials. Because of the negative side-effects of certain chemical techniques, biological methods have been proposed as a desired and environmentally friendly strategy for reducing concrete porosity and diminishing water absorption. This paper presents the results of an experimental investigation carried out to evaluate the influence of Sporosarcina pasteurii bacteria on the behaviour of two types of concretes (light weight aggregate concrete and normal weight concrete). The resistance of specimens to water penetration by testing water absorption and evaluating the electrical resistance of those concretes was examined and compared. As a conclusion, 20% increase in electrical resistance and 10% reduction in water absorption of lightweight aggregate concrete (LWAC) and for normal concrete the results show 7% decrease in water absorption and almost 10% increase in electrical resistance.
Abstract: Artificial lightweight aggregates have a wide range of applications in industry and engineering. Nowadays, the usage of this material in geotechnical activities, especially as backfill in retaining walls has been growing due to the specific characteristics which make it a competent alternative to the conventional geotechnical materials. In practice, a material with lower weight but higher shear strength parameters would be ideal as backfill behind retaining walls because of the important roles that these parameters play in decreasing the overall active lateral earth pressure. In this study, two types of Light Expanded Clay Aggregates (LECA) produced in the Leca factory are investigated. LECA is made in a rotary kiln by heating natural clay at different temperatures up to 1200 °C making quasi-spherical aggregates with different sizes ranged from 0 to 25 mm. The loose bulk density of these aggregates is between 300 and 700 kN/m3. The purpose of this research is to determine the stress-strain behavior, shear strength parameters, and the energy absorption of LECA materials. Direct shear tests were conducted at five normal stresses of 25, 50, 75, 100, and 200 kPa. In addition, conventional triaxial compression tests were operated at confining pressures of 50, 100, and 200 kPa to examine stress-strain behavior. The experimental results show a high internal angle of friction and even a considerable amount of nominal cohesion despite the granular structure of LECA. These desirable properties along with the intrinsic low density of these aggregates make LECA as a very proper material in geotechnical applications. Furthermore, the results demonstrate that lightweight aggregates may have high energy absorption that is excellent alternative material in seismic isolations.
Abstract: Lightweight concrete is being used in the construction industry as a building material in its own right. Ultra-lightweight concrete can be applied as a filler and support material for the manufacturing of composite building materials. This paper is about the development of a stable and reproducible ultra-lightweight concrete with the inclusion of poly-lactic acid (PLA) beads and assessing the feasibility of PLA as a lightweight aggregate that will deliver advantages such as a more eco-friendly concrete and a non-petroleum polymer aggregate. In total, sixty-three samples were prepared and the effectiveness of mineral admixture, curing conditions, water-cement ratio, PLA ratio, EPS ratio and perlite ratio on compressive strength of perlite concrete are studied. The results show that PLA particles are sensitive to alkali environment of cement paste and considerably shrank and lost their strength. A higher compressive strength and a lower density was observed when expanded polystyrene (EPS) particles replaced PLA beads. In addition, a set of equations is proposed to estimate the water-cement ratio, cement content and compressive strength of perlite concrete.
Abstract: Problems insulation of building structures is often
closely connected with the problem of moisture remediation. In the
case of historic buildings or if only part of the redevelopment of
envelope of structures, it is not possible to apply the classical external
thermal insulation composite systems. This application is mostly
effective thermal insulation plasters with high porosity and controlled
capillary properties which assures improvement of thermal properties
construction, its diffusion openness towards the external environment
and suitable treatment capillary properties of preventing the
penetration of liquid moisture and salts thereof toward the outer
surface of the structure.
With respect to the current trend of reducing the energy
consumption of building structures and reduce the production of CO2
is necessary to develop capillary-active materials characterized by
their low density, low thermal conductivity while maintaining good
mechanical properties. The aim of researchers at the Faculty of Civil
Engineering, Brno University of Technology is the development and
study of hygrothermal behaviour of optimal materials for thermal
insulation and rehabilitation of building structures with the possible
use of alternative, less energy demanding binders in comparison with
conventional, frequently used binder, which represents cement.
The paper describes the evaluation of research activities aimed at
the development of thermal insulation and repair materials using
lightweight aggregate and alternative binders such as metakaolin and
finely ground fly ash.
Abstract: This paper is concerning the issues of behaviour of
lightweight expanded clay aggregates concrete exposed to high
temperature. Lightweight aggregates from expanded clay are
produced by firing of row material up to temperature 1050°C.
Lightweight aggregates have suitable properties in terms of volume
stability, when exposed to temperatures up to 1050°C, which could
indicate their suitability for construction applications with higher risk
of fire. The test samples were exposed to heat by using the standard
temperature-time curve ISO 834. Negative changes in resulting
mechanical properties, such as compressive strength, tensile strength,
and flexural strength were evaluated. Also visual evaluation of the
specimen was performed. On specimen exposed to excessive heat, an
explosive spalling could be observed, due to evaporation of
considerable amount of unbounded water from the inner structure of
the concrete.
Abstract: Well-designed composite steel and concrete structures
highlight the good material properties and lower the deficiencies of
steel and concrete, in particular they make use of high tensile strength
of steel and high stiffness of concrete. The most common composite
steel and concrete structure is a simply supported beam, which
concrete slab transferring the slab load to a beam is connected to the
steel cross-section. The aim of this paper is to find the most adequate
numerical model of a simply supported composite beam with the
cross-sectional and material parameters based on the results of a
processed parametric study and numerical analysis. The paper also
evaluates the suitability of using compact concrete with the
lightweight aggregates for composite steel and concrete beams. The
most adequate numerical model will be used in the resent future to
compare the results of laboratory tests.
Abstract: When insulation and rehabilitation of structures is important to use quality building materials with high utility value. One potentially interesting and promising groups of construction materials in this area are advanced, thermally insulating plaster silicate based. With the present trend reduction of energy consumption of building structures and reducing CO2 emissions to be developed capillary-active materials that are characterized by their low density, low thermal conductivity while maintaining good mechanical properties.
The paper describes the results of research activities aimed at the development of thermal insulating and rehabilitation material ongoing at the Technical University in Brno, Faculty of Civil Engineering. The achieved results of this development will be the basis for subsequent experimental analysis of the influence of thermal and moisture loads developed on these materials.
Abstract: Structural lightweight concrete is used primarily to reduce the dead-load weight in concrete members such as floors in high-rise buildings and bridge decks. With given materials, it is generally desired to have the highest possible strength/unit weight ratio with the lowest cost of concrete. The work presented herein is part of an ongoing research project that investigates the properties of concrete mixes containing locally available Scoria lightweight aggregates and mineral admixtures. Properties considered included: workability, unit weight, compressive strength, and splitting tensile strength. Test results indicated that developing structural lightweight concretes (SLWC) using locally available Scoria lightweight aggregates and specific blends of silica fume and fly ash seems to be feasible. The stress-strain diagrams plotted for the structural LWC mixes developed in this investigation were comparable to a typical stress-strain diagram for normal weight concrete with relatively larger strain capacity at failure in case of LWC.