Abstract: Personal computers draw non-sinusoidal current
with odd harmonics more significantly. Power Quality of
distribution networks is severely affected due to the flow of these
generated harmonics during the operation of electronic loads. In
this paper, mathematical modeling of odd harmonics in current like
3rd, 5th, 7th and 9th influencing the power quality has been presented.
Live signals have been captured with the help of power quality
analyzer for analysis purpose. The interesting feature is that Total
Harmonic Distortion (THD) in current decreases with the increase
of nonlinear loads has been verified theoretically. The results
obtained using mathematical expressions have been compared with
the practical results and exciting results have been found.
Abstract: The range of the output power is a very important and evident limitation of two-level inverters. In order to overcome this disadvantage, multilevel inverters are introduced. Recently, Cascade H-Bridge inverters have emerged as one of the popular converter topologies used in numerous industrial applications. The modulation switching strategies such as phase shifted carrier based Pulse Width Modulation (PWM) technique and Stair case modulation with Selective Harmonic Elimination (SHE) PWM technique are generally used. NR method is used to solve highly non linear transcendental equations which are formed by SHEPWM method. Generally NR method has a drawback of requiring good initial guess but in this paper a new approach is implemented for NR method with any random initial guess. A three phase CHB 11-level inverter is chosen for analysis. MATLAB/SIMULINK programming environment and harmonic profiles are compared. Finally this paper presents a method at fundamental switching frequency with least % THDV.
Abstract: This paper present a MATLAB-SIMULINK model of a single phase 2.5 KVA, 240V RMS controlled PV VSI (Photovoltaic Voltage Source Inverter) inverter using IGBTs (Insulated Gate Bipolar Transistor). The behavior of output voltage, output current, and the total harmonic distortion (THD), with the variation in input dc blocking capacitor (Cdc), for linear and non-linear load has been analyzed. The values of Cdc as suggested by the other authors in their papers are not clearly defined and it poses difficulty in selecting the proper value. As the dc power stored in Cdc, (generally placed parallel with battery) is used as input to the VSI inverter. The simulation results shows the variation in the output voltage and current with different values of Cdc for linear and non-linear load connected at the output side of PV VSI inverter and suggest the selection of suitable value of Cdc.
Abstract: A high-frequency low-power sinusoidal quadrature
oscillator is presented through the use of two 2nd-order low-pass
current-mirror (CM)-based filters, a 1st-order CM low-pass filter and
a CM bilinear transfer function. The technique is relatively simple
based on (i) inherent time constants of current mirrors, i.e. the
internal capacitances and the transconductance of a diode-connected
NMOS, (ii) a simple negative resistance RN formed by a resistor load
RL of a current mirror. Neither external capacitances nor inductances
are required. As a particular example, a 1.9-GHz, 0.45-mW, 2-V
CMOS low-pass-filter-based all-current-mirror sinusoidal quadrature
oscillator is demonstrated. The oscillation frequency (f0) is 1.9 GHz
and is current-tunable over a range of 370 MHz or 21.6 %. The
power consumption is at approximately 0.45 mW. The amplitude
matching and the quadrature phase matching are better than 0.05 dB
and 0.15°, respectively. Total harmonic distortions (THD) are less
than 0.3 %. At 2 MHz offset from the 1.9 GHz, the carrier to noise
ratio (CNR) is 90.01 dBc/Hz whilst the figure of merit called a
normalized carrier-to-noise ratio (CNRnorm) is 153.03 dBc/Hz. The
ratio of the oscillation frequency (f0) to the unity-gain frequency (fT)
of a transistor is 0.25. Comparisons to other approaches are also
included.
Abstract: This paper proposes a feed-forward control in a halfbridge
resonant dc link inverter. The configuration of feed-forward
control is based on synchronous sigma-delta modulation and the halfbridge
resonant dc link inverter consists of two inductors, one
capacitor and two power switches. The simulation results show the
proposed technique can reject non-ideal dc bus improving the total
harmonic distortion.