Abstract: This paper presents the influence of preloading on a)
the contact tractions, b) slip levels and c) stresses at the dovetail
blade-disc interface of an aero-engine through a three-dimensional
(3D) finite element (FE) modeling and analysis. The preloading is
applied by an interference fit at the dovetail interface and the bulk
loading is applied through the rotational speed of rotor. Preloading at
the dovetail interface reduces the peak contact pressure developed
due to bulk loading up to 35%, and reduces the peak contact pressure
and stress difference between top and bottom contact edges.
Increasing the level of preloading reduces the cyclic stress amplitude
at the interface up to certain values of preload and as a consequence,
an improvement in fatigue life could be expected. Fretting damage,
due to vibration and wind milling effect during engine ground
condition, can be minimized by preloading the dovetail interface.
Abstract: Helical milling operations are used to generate or
enlarge boreholes by means of a milling tool. The bore diameter can be
adjusted through the diameter of the helical path. The kinematics of
helical milling on a three axis machine tool is analysed firstly. The
relationships between processing parameters, cutting tool geometry
characters with machined hole feature are formulated. The feed motion
of the cutting tool has been decomposed to plane circular feed and
axial linear motion. In this paper, the time varying cutting forces acted
on the side cutting edges and end cutting edges of the flat end cylinder
miller is analysed using a discrete method separately. These two
components then are combined to produce the cutting force model
considering the complicated interaction between the cutters and
workpiece. The time varying cutting force model describes the
instantaneous cutting force during processing. This model could be
used to predict cutting force, calculate statics deflection of cutter and
workpiece, and also could be the foundation of dynamics model and
predicting chatter limitation of the helical milling operations.
Abstract: This paper proposes a method for speckle reduction in
medical ultrasound imaging while preserving the edges with the
added advantages of adaptive noise filtering and speed. A nonlinear
image diffusion method that incorporates local image parameter,
namely, scatterer density in addition to gradient, to weight the
nonlinear diffusion process, is proposed. The method was tested for
the isotropic case with a contrast detail phantom and varieties of
clinical ultrasound images, and then compared to linear and some
other diffusion enhancement methods. Different diffusion parameters
were tested and tuned to best reduce speckle noise and preserve
edges. The method showed superior performance measured both
quantitatively and qualitatively when incorporating scatterer density
into the diffusivity function. The proposed filter can be used as a
preprocessing step for ultrasound image enhancement before
applying automatic segmentation, automatic volumetric calculations,
or 3D ultrasound volume rendering.
Abstract: A number of routing algorithms based on learning
automata technique have been proposed for communication
networks. How ever, there has been little work on the effects of
variation of graph scarcity on the performance of these algorithms. In
this paper, a comprehensive study is launched to investigate the
performance of LASPA, the first learning automata based solution to
the dynamic shortest path routing, across different graph structures
with varying scarcities. The sensitivity of three main performance
parameters of the algorithm, being average number of processed
nodes, scanned edges and average time per update, to variation in
graph scarcity is reported. Simulation results indicate that the LASPA
algorithm can adapt well to the scarcity variation in graph structure
and gives much better outputs than the existing dynamic and fixed
algorithms in terms of performance criteria.
Abstract: An analysis is performed to study the influence of nonuniform double slot suction on a steady laminar boundary layer flow over a rotating sphere when fluid properties such as viscosity and Prandtl number are inverse linear functions of temperature. Nonsimilar solutions have been obtained from the starting point of the streamwise co-ordinate to the exact point of separation. The difficulties arising at the starting point of the streamwise co-ordinate, at the edges of the slot and at the point of separation have been overcome by applying an implicit finite difference scheme in combination with the quasi-linearization technique and an appropriate selection of the finer step sizes along the stream-wise direction. The present investigation shows that the point of ordinary separation can be delayed by nonuniform double slot suction if the mass transfer rate is increased and also if the slots are positioned further downstream. In addition, the investigation reveals that double slot suction is found to be more effective compared to a single slot suction in delaying ordinary separation. As rotation parameter increase the point of separation moves upstream direction.
Abstract: Fourier transform infrared (FT-IR) spectroscopic imaging
is an emerging technique that provides both chemically and
spatially resolved information. The rich chemical content of data
may be utilized for computer-aided determinations of structure and
pathologic state (cancer diagnosis) in histological tissue sections for
prostate cancer. FT-IR spectroscopic imaging of prostate tissue has
shown that tissue type (histological) classification can be performed to
a high degree of accuracy [1] and cancer diagnosis can be performed
with an accuracy of about 80% [2] on a microscopic (≈ 6μm)
length scale. In performing these analyses, it has been observed
that there is large variability (more than 60%) between spectra from
different points on tissue that is expected to consist of the same
essential chemical constituents. Spectra at the edges of tissues are
characteristically and consistently different from chemically similar
tissue in the middle of the same sample. Here, we explain these
differences using a rigorous electromagnetic model for light-sample
interaction. Spectra from FT-IR spectroscopic imaging of chemically
heterogeneous samples are different from bulk spectra of individual
chemical constituents of the sample. This is because spectra not
only depend on chemistry, but also on the shape of the sample.
Using coupled wave analysis, we characterize and quantify the nature
of spectral distortions at the edges of tissues. Furthermore, we
present a method of performing histological classification of tissue
samples. Since the mid-infrared spectrum is typically assumed to
be a quantitative measure of chemical composition, classification
results can vary widely due to spectral distortions. However, we
demonstrate that the selection of localized metrics based on chemical
information can make our data robust to the spectral distortions
caused by scattering at the tissue boundary.
Abstract: Computations with higher than the IEEE 754 standard double-precision (about 16 significant digits) are required recently. Although there are available software routines in Fortran and C for high-precision computation, users are required to implement such routines in their own computers with detailed knowledges about them. We have constructed an user-friendly online system for octupleprecision computation. In our Web system users with no knowledges about high-precision computation can easily perform octupleprecision computations, by choosing mathematical functions with argument(s) inputted, by writing simple mathematical expression(s) or by uploading C program(s). In this paper we enhance the Web system above by adding the facility of uploading Fortran programs, which have been widely used in scientific computing. To this end we construct converter routines in two stages.
Abstract: Median filter is widely used to remove impulse noise
without blurring sharp edges. However, when noise level increased,
or with thin edges, median filter may work poorly. This paper
proposes a new filter, which will detect edges along four possible
directions, and then replace noise corrupted pixel with estimated
noise-free edge median value. Simulations show that the proposed
multi-stage directional median filter can provide excellent
performance of suppressing impulse noise in all situations.
Abstract: This paper presents a unified approach based graph
theory and system theory postulates for the modeling and analysis
of Simple open cycle Gas turbine system. In the present paper, the
simple open cycle gas turbine system has been modeled up to its subsystem
level and system variables have been identified to develop the
process subgraphs. The theorems and algorithms of the graph theory
have been used to represent behavioural properties of the system like
rate of heat and work transfers rates, pressure drops and temperature
drops in the involved processes of the system. The processes have
been represented as edges of the process subgraphs and their limits
as the vertices of the process subgraphs. The system across variables
and through variables has been used to develop terminal equations of
the process subgraphs of the system. The set of equations developed
for vertices and edges of network graph are used to solve the system
for its process variables.