Design of Low Noise Amplifiers for 10 GHz Application

This work deals with the designing of an efficient low noise amplifier for 10.00 GHz applications. The amplifier is designed using Gallium Arsenide High Electron Mobility Transistor (GaAs HEMT) ATF – 36077 with inductive source degeneration technique which is one of the techniques to improve the stability of the potentially unstable device and make it unconditionally stable. Also, different substrates are used for designing the LNA to identify the suitable substrate that gives optimum results. It is observed that the noise immunity is more in Low Noise Amplifier (LNA) designed using RT Duroid 5880 substrate. This design resulted in noise figure of 0.859 dB and power gain of 15.530 dB. The comparative analysis of the LNA design is discussed in this paper.

Reliability Analysis of k-out-of-n : G System Using Triangular Intuitionistic Fuzzy Numbers

In the present paper, we analyze the vague reliability of k-out-of-n : G system (particularly, series and parallel system) with independent and non-identically distributed components, where the reliability of the components are unknown. The reliability of each component has been estimated using statistical confidence interval approach. Then we converted these statistical confidence interval into triangular intuitionistic fuzzy numbers. Based on these triangular intuitionistic fuzzy numbers, the reliability of the k-out-of-n : G system has been calculated. Further, in order to implement the proposed methodology and to analyze the results of k-out-of-n : G system, a numerical example has been provided.

Automation System for Optimization of Electrical and Thermal Energy Production in Cogenerative Gas Power Plants

The system is made with main distributed components: First Level: Industrial Computers placed in Control Room (monitors thermal and electrical processes based on the data provided by the second level); Second Level: PLCs which collects data from process and transmits information on the first level; also takes commands from this level which are further, passed to execution elements from third level; Third Level: field elements consisting in 3 categories: data collecting elements; data transfer elements from the third level to the second; execution elements which take commands from the second level PLCs and executes them after which transmits the confirmation of execution to them. The purpose of the automatic functioning is the optimization of the co-generative electrical energy commissioning in the national energy system and the commissioning of thermal energy to the consumers. The integrated system treats the functioning of all the equipments and devices as a whole: Gas Turbine Units (GTU); MT 20kV Medium Voltage Station (MVS); 0,4 kV Low Voltage Station (LVS); Main Hot Water Boilers (MHW); Auxiliary Hot Water Boilers (AHW); Gas Compressor Unit (GCU); Thermal Agent Circulation Pumping Unit (TPU); Water Treating Station (WTS).