Abstract: The compression-absorption heat pump (C-A HP), one
of the promising heat recovery equipments that make process hot
water using low temperature heat of wastewater, was evaluated by
computer simulation. A simulation program was developed based on
the continuity and the first and second laws of thermodynamics. Both
the absorber and desorber were modeled using UA-LMTD method. In
order to prevent an unfeasible temperature profile and to reduce
calculation errors from the curved temperature profile of a mixture,
heat loads were divided into lots of segments. A single-stage
compressor was considered. A compressor cooling load was also
taken into account. An isentropic efficiency was computed from the
map data. Simulation conditions were given based on the system
consisting of ordinarily designed components. The simulation results
show that most of the total entropy generation occurs during the
compression and cooling process, thus suggesting the possibility that
system performance can be enhanced if a rectifier is introduced.
Abstract: From environmental aspect purification of ammonia
containing wastewater is expected. High efficiency ammonia
desorption can be done from the water by air on proper temperature.
After the desorption process, ammonia can be recovered and used in
another technology. The calculation method described below give
some methods to find either the minimum column height or ammonia
rich solution of the effluent.
Abstract: Abstract–Indoor air (VOCs) samples were collected
simultaneously from variety of indoors (e.g. living rooms, baby-s
rooms) and outdoor environments which were voluntarily selected
from the houses in which pregnant residents live throughout Ankara.
This is the first comprehensive study done in Turkey starting from
prenatal period and continued till the babies had one year old. VOCs
levels were measured over 76 homes. Air samples were collected in
Tenax TA sorbent filled tubes with active sampling method and
analyzed with Thermal Desorber and Gas Chromatography/Mass
spectrometry (TD-GC/MS). At the first sampling period in the baby-s
rooms maximum concentration of toluene was measured about
240.77μg.m-3 and in the living rooms maximum concentration of
naphthalene was 180.24μg.m-3. At the second sampling period in the
baby-s rooms maximum concentration of toluene was measured
about 144.97μg.m-3 and in the living rooms maximum concentration
of naphthalene was 247.89μg.m-3. Concentration of TVOCs in the
first period was generally higher than the second period.