Abstract: Surplus electricity can be converted into potential energy via pumped hydroelectric storage for future usage. Similarly, thermo-electric energy storage (TEES) uses heat pumps equipped with thermal storage to convert electrical energy into thermal energy; the stored energy is then converted back into electrical energy when necessary using a heat engine. The greatest advantage of this method is that, unlike pumped hydroelectric storage and compressed air energy storage, TEES is not restricted by geographical constraints. In this study, performance variation of the TEES according to the changes in cold-side storage temperature was investigated by simulation method.
Abstract: In order to compare the performance of the carbon dioxide and HFC-125 heat pumps for medium-and high-temperature heating, both heat pump cycles were optimized using a simulation method. To fairly compare the performance of the cycles by using different working fluids, each cycle was optimized from the viewpoint of heating COP by two design parameters. The first is the gas cooler exit temperature and the other is the ratio of the overall heat conductance of the gas cooler to the combined overall heat conductance of the gas cooler and the evaporator. The inlet and outlet temperatures of secondary fluid of the gas cooler were fixed at 40/90°C and 40/150°C.The results shows that the HFC-125 heat pump has 6% higher heating COP than carbon dioxide heat pump when the heat sink exit temperature is fixed at 90ºC, while the latter outperforms the former when the heat sink exit temperature is fixed at 150ºC under the simulation conditions considered in the present study.
Abstract: The compression-absorption heat pump (C-A HP), one
of the promising heat recovery equipments that make process hot
water using low temperature heat of wastewater, was evaluated by
computer simulation. A simulation program was developed based on
the continuity and the first and second laws of thermodynamics. Both
the absorber and desorber were modeled using UA-LMTD method. In
order to prevent an unfeasible temperature profile and to reduce
calculation errors from the curved temperature profile of a mixture,
heat loads were divided into lots of segments. A single-stage
compressor was considered. A compressor cooling load was also
taken into account. An isentropic efficiency was computed from the
map data. Simulation conditions were given based on the system
consisting of ordinarily designed components. The simulation results
show that most of the total entropy generation occurs during the
compression and cooling process, thus suggesting the possibility that
system performance can be enhanced if a rectifier is introduced.