Abstract: The sub-task pattern in terms of deviations and defects
should be identified and understood in order to improve the quality of
practices in construction projects. Therefore, sub-task susceptibility
to exposure to deviations and defects has been evaluated and
classified via six classifications proposed in this study. Thirty-four
case studies of specific sub-tasks (from compression members in
constructed concrete structures) were collected from seven
construction projects in order to examine the study’s proposed
classifications. The study revealed that the sub-task has a high
sensitivity to deviation, where 91% of the cases were recorded as
deviations; however, only 19% of cases were recorded as defects.
Other findings were that the actual work during the execution process
is a high source of deviation for this sub-task (74%), while only 26%
of the source of deviation was due to both design documentation and
the actual work. These findings significantly imply that the study’s
proposed classifications could be used to determine the pattern of
each sub-task and develop proactive actions to overcome issues of
sub-task deviations and defects.
Abstract: A local municipality has decided to build a sewage pit
to receive residential sewage waste arriving by tank trucks. Daily
accumulated waste are to be pumped to a nearby waste water
treatment facility to be re-consumed for agricultural and construction
projects. A discrete-event simulation model using Arena Software
was constructed to assist in defining the capacity of the system in
cubic meters, number of tank trucks to use the system, number of
unload docks required, number of standby areas needed and
manpower required for data collection at entrance checkpoint and
truck tank load toxicity testing. The results of the model are
statistically validated. Simulation turned out to be an excellent tool
in the facility planning effort for the pit project, as it insured smooth
flow lines of tank trucks load discharge and best utilization of
facilities on site.