Abstract: Although many studies on the assembly technology of
the bridge construction have dealt mostly with on the pier, girder or the
deck of the bridge, studies on the prefabricated barrier have rarely been
performed. For understanding structural characteristics and
application of the concrete barrier in the modular bridge, which is an
assembly of structure members, static loading test was performed.
Structural performances as a road barrier of the three methods,
conventional cast-in-place(ST), vertical bolt connection(BVC) and
horizontal bolt connection(BHC) were evaluated and compared
through the analyses of load-displacement curves, strain curves of the
steel, concrete strain curves and the visual appearances of crack
patterns. The vertical bolt connection(BVC) method demonstrated
comparable performance as an alternative to conventional
cast-in-place(ST) while providing all the advantages of prefabricated
technology. Necessities for the future improvement in nuts
enforcement as well as legal standard and regulation are also
addressed.
Abstract: This paper presents the experimental results on
artificial ageing test of 22 kV XLPE cable for distribution system
application in Thailand. XLPE insulating material of 22 kV cable
was sliced to 60-70 μm in thick and was subjected to ac high voltage
at 23
Ôùª
C, 60
Ôùª
C and 75
Ôùª
C. Testing voltage was constantly applied to
the specimen until breakdown. Breakdown voltage and time to
breakdown were used to evaluate life time of insulating material.
Furthermore, the physical model by J. P. Crine for predicts life time
of XLPE insulating material was adopted as life time model and was
calculated in order to compare the experimental results. Acceptable
life time results were obtained from Crine-s model comparing with
the experimental result. In addition, fourier transform infrared
spectroscopy (FTIR) for chemical analysis and scanning electron
microscope (SEM) for physical analysis were conducted on tested
specimens.
Abstract: Many footbridges have natural frequencies that
coincide with the dominant frequencies of the pedestrian-induced
load and therefore they have a potential to suffer excessive vibrations
under dynamic loads induced by pedestrians. Some of the design
standards introduce load models for pedestrian loads applicable for
simple structures. Load modeling for more complex structures, on the
other hand, is most often left to the designer. The main focus of this
paper is on the human induced forces transmitted to a footbridge and
on the ways these loads can be modeled to be used in the dynamic
design of footbridges. Also design criteria and load models proposed
by widely used standards were introduced and a comparison was
made. The dynamic analysis of the suspension bridge in Kolin in the
Czech Republic was performed on detailed FEM model using the
ANSYS program system. An attempt to model the load imposed by a
single person and a crowd of pedestrians resulted in displacements
and accelerations that are compared with serviceability criteria.
Abstract: Biometric techniques are gaining importance for
personal authentication and identification as compared to the
traditional authentication methods. Biometric templates are
vulnerable to variety of attacks due to their inherent nature. When a
person-s biometric is compromised his identity is lost. In contrast to
password, biometric is not revocable. Therefore, providing security
to the stored biometric template is very crucial. Crypto biometric
systems are authentication systems, which blends the idea of
cryptography and biometrics. Fuzzy vault is a proven crypto
biometric construct which is used to secure the biometric templates.
However fuzzy vault suffer from certain limitations like nonrevocability,
cross matching. Security of the fuzzy vault is affected
by the non-uniform nature of the biometric data. Fuzzy vault when
hardened with password overcomes these limitations. Password
provides an additional layer of security and enhances user privacy.
Retina has certain advantages over other biometric traits. Retinal
scans are used in high-end security applications like access control to
areas or rooms in military installations, power plants, and other high
risk security areas. This work applies the idea of fuzzy vault for
retinal biometric template. Multimodal biometric system
performance is well compared to single modal biometric systems.
The proposed multi modal biometric fuzzy vault includes combined
feature points from retina and fingerprint. The combined vault is
hardened with user password for achieving high level of security.
The security of the combined vault is measured using min-entropy.
The proposed password hardened multi biometric fuzzy vault is
robust towards stored biometric template attacks.
Abstract: In this study we investigate the insertion of
pioglitazone, a Thiazolidinedione, into the two different sizes of
Carbon nanotub. It was shown that the insertion of pioglitazone into
the carbon nanotube in a water solute environment could be related
to the diameter of the nanotube and in the flow of the waters via
hydrophilic interactions. This encapsulated drug-carbon nanotube
molecule can be further applicable in other investigations in target
therapy with these agents regarding to reduce their potential toxic
effects.
Abstract: The importance of ensuring safe meat handling and
processing practices has been demonstrated in global reports on food
safety scares and related illness and deaths. This necessitated stricter
meat safety control strategies. Today, many countries have regulated
towards preventative and systematic control over safe meat
processing at abattoirs utilizing the Hazard Analysis Critical Control
Point (HACCP) principles. HACCP systems have been reported as
effective in managing food safety risks, if correctly implemented.
South Africa has regulated the Hygiene Management System (HMS)
based on HACCP principles applicable to abattoirs. Regulators utilise
the Hygiene Assessment System (HAS) to audit compliance at
abattoirs. These systems were benchmarked from the United
Kingdom (UK). Little research has been done them since inception as
of 2004. This paper presents a review of the two systems, its
implementation and comparison with HACCP. Recommendations are
made for future research to demonstrate the utility of the HMS and
HAS in assuring safe meat to consumers.