Abstract: The calculation of buckling length factor (K) for steel
frames columns is a major and governing processes to determine the
dimensions steel frame columns cross sections during design. The
buckling length of steel frames columns has a direct effect on the cost
(weight) of using cross section. A new formula is required to
determine buckling length factor (K) by simplified way. In this
research a new formula for buckling length factor (K) was established
to determine by accurate method for a limited interval of columns
ends rigidity (GA, GB). The new formula can be used ease to
evaluate the buckling length factor without needing to complicated
equations or difficult charts.