Abstract: The evaluation of the convective heat transfer of flow in passages with rectangular cross section is still of interest for the heat transfer investigators, as in the air heater solar collectors. The aim of this paper is to present investigation results on the natural convection heat transfer in a solar air heater. The effect of the channel length as heat transfer surface and the inclination of the passage were investigated. The results were obtained experimentally and theoretically. For that, an experimental test rig was fabricated with channel lengths of 1m, 1.5m, and 2m. For each length, the air outlet and inlet temperatures, absorber and cover temperatures, solar radiation intensity and air flow rate were measured at 10o, 30o, 50o, 70o, and 90o tilt angles. Measurements were recorded every 2 hours interval to investigate the transient behavior of the system. The experimental and theoretical results are presented in terms of Nu number versus Ra number and discussed. The percentages of differences between experimental and theoretical results are within the margin of 6% to 13%, effectively. It is recommended to extend the investigation to study the same configurations with different artificial surface roughing by ribs or pins.
Abstract: Hybrid photovoltaic thermal (PV/T) solar system comprises a solar collector which is disposed on photovoltaic solar cells. The disadvantage of a conventional photovoltaic cell is that its performance decreases as the temperature increases. Indeed, part of the solar radiation is converted into electricity and is dissipated as heat, increasing the temperature of the photovoltaic cell with respect to the ambient temperature. The objective of this work is to study experimentally and implement a hybrid prototype to evaluate electrical and thermal performance. In this paper, an experimental study of two new configurations of hybrid collectors is exposed. The results are given and interpreted. The two configurations of absorber studied are a new combination with tubes and galvanized tank, the other is a tubes and sheet.
Abstract: A solar powered air heating system using one ended evacuated tubes is experimentally investigated. A solar air heater containing forty evacuated tubes is used for heating purpose. The collector surface area is about 4.44 m2. The length and outer diameters of the outer glass tube and absorber tube are 1500, 47 and 37 mm, respectively. In this experimental setup, we have a header (heat exchanger) of square shape (190 mm x 190 mm). The length of header is 1500 mm. The header consists of a hollow pipe in the center whose diameter is 60 mm through which the air is made to flow. The experimental setup contains approximately 108 liters of water. Water is working as heat collecting medium which collects the solar heat falling on the tubes. This heat is delivered to the air flowing through the header pipe. This heat flow is due to natural convection and conduction. The outlet air temperature depends upon several factors along with air flow rate and solar radiation intensity. The study has been done for both up-flow and down-flow of air in header in similar weather conditions, at different flow rates. In the present investigations the study has been made to find the effect of intensity of solar radiations and flow rate of air on the out let temperature of the air with time and which flow is more efficient. The obtained results show that the system is highly effective for the heating in this region. Moreover, it has been observed that system is highly efficient for the particular flow rate of air. It was also observed that downflow configuration is more effective than up-flow condition at all flow rates due to lesser losses in down-flow. The results show that temperature differences of upper head and lower head, both of water and surface of pipes on the respective ends is lower in down-flow.
Abstract: Energy and exergy study of air-water combined solar collector which is called dual purpose solar collector (DPSC) is investigated. The method of ε - NTU is used. Analysis is performed for triangle channels. Parameters like the air flow rate and water inlet temperature are studied. Results are shown that DPSC has better energy and exergy efficiency than single collector. In addition, the triangle passage with water inlet temperature of 60O C has shown better exergy and energy efficiency.
Abstract: It is well known that surface enhancements play an important role in augmenting the thermal performance of flat plate solar collector. In this paper, an attempt is made to explain in a comparative way the effect of surface geometry of solar collector having dimple geometry with that of a flat plate solar collector of the same size. A CFD analysis was carried out for the two cases, subjected to a constant heat flux of 600W/m2 and 1000W/m2. It can be inferred from the study that the absorber plate temperature shows a rise of average surface temperature of about 50C for the dimple solar collector when compared to a flat plate solar collector. Most importantly, the average exit water temperature shows a marked improvement of about 5.50C for a dimple solar collector as compared to that of a flat plate solar collector.
Abstract: The objective of this paper was to designing a
ventilation system to enhance the performance of roof solar collector
(RSC) for reducing heat accumulation inside the house. The RSC has
1.8 m2 surface area made of CPAC monier roof tiles on the upper part
and gypsum board on the lower part. The space between CPAC
monier and gypsum board was fixed at 14 cm.
Ventilation system of modified roof solar collector (modified
RSC) consists of 9 tubes of 0.15m diameter and installed in the
lower part of RSC. Experimental result showed that the temperature
of the room, and attic temperature. The average temperature
reduction of room of house used modified RSC is about 2oC. and the
percentage of room temperature reduction varied between 0 to 10%.
Therefore, modified RSC is an interesting option in the sense that it
promotes solar energy and conserve energy.
Abstract: A solar refrigeration system based on the adsorptiondesorption
phenomena is designed and analyzed. An annular tubular
generator filled with silica gel adsorbent and with a perforated inner
cylinder is integrated within a flat solar collector. The working fluid
in the refrigeration cycle is water. The thermodynamic analysis and
because of the temperature level that could be attained with a flat
solar collector it is required that the system operates under vacuum
conditions. In order to enhance the performance of the system and to
get uniform temperature in the silica gel and higher desorbed mass,
an apparatus for rotation of the generator is incorporated in the
system. Testing is carried out and measurements are taken on the
designed installation. The effect of rotation is checked on the
temperature distribution and on the performance of this machine and
compared to the flat solar collector with fixed generator.
Abstract: Solar energy is the most “available", ecological and clean energy. This energy can be used in active or passive mode. The active mode implies the transformation of solar energy into a useful energy. The solar energy can be transformed into thermal energy, using solar collectors. In these collectors, the active and the most important element is the absorber, material which performs the absorption of solar radiation and, in at the same time, limits its reflection. The paper presents some aspects regarding the IR absorbing material – a type of cermets, used as absorber in the solar collectors, by X Ray Diffraction Technique (XRD) characterization.
Abstract: This paper presents the exergy analysis of a
desalination unit using humidification-dehumidification process.
Here, this unit is considered as a thermal system with three main
components, which are the heating unit by using a solar collector, the
evaporator or the humidifier, and the condenser or the dehumidifier.
In these components the exergy is a measure of the quality or grade
of energy and it can be destroyed in them. According to the second
law of thermodynamics this destroyed part is due to irreversibilities
which must be determined to obtain the exergetic efficiency of the
system.
In the current paper a computer program has been developed using
visual basic to determine the exergy destruction and the exergetic
efficiencies of the components of the desalination unit at variable
operation conditions such as feed water temperature, outlet air
temperature, air to feed water mass ratio and salinity, in addition to
cooling water mass flow rate and inlet temperature, as well as
quantity of solar irradiance.
The results obtained indicate that the exergy efficiency of the
humidifier increases by increasing the mass ratio and decreasing the
outlet air temperature. In the other hand the exergy efficiency of the
condenser increases with the increase of this ratio and also with the
increase of the outlet air temperature.
Abstract: Majority of pepper farmers in Malaysia are using the
open-sun method for drying the pepper berries. This method is time
consuming and exposed the berries to rain and contamination. A
maintenance-friendly and properly enclosed dryer is therefore
desired. A dryer design with a solar collector and a chimney was
studied and adapted to suit the needs of small-scale pepper farmers in
Malaysia. The dryer will provide an environment with an optimum
operating temperature meant for drying pepper berries. The dryer
model was evaluated by using commercially available computational
fluid dynamic (CFD) software in order to understand the heat and
mass transfer inside the dryer. Natural convection was the only mode
of heat transportation considered in this study as in accordance to the
idea of having a simple and maintenance-friendly design. To
accommodate the effect of low buoyancy found in natural convection
driers, a biomass burner was integrated into the solar dryer design.