Abstract: Magnetically controlled microelectromechanical system (MCMEMS) switches is one of the directions in the field of micropower switching technology. MCMEMS switches are a promising alternative to Hall sensors and reed switches. The most important parameter for MCMEMS is the contact resistance, which should have a minimum value and is to be stable for the entire duration of service life. The value and stability of the contact resistance is mainly determined by the contact coating material. This paper presents the research results of a contact coating based on nanoscale ruthenium films obtained by electrolytic deposition. As a result of the performed investigations, the deposition modes of ruthenium films are chosen, the regularities of the contact resistance change depending on the number of contact switching, and the coating roughness are established. It is shown that changing the coating roughness makes it possible to minimize the contact resistance.
Abstract: This study is concerned with pH solution detection
using 2 × 4 flexible sensor array based on a plastic polyethylene
terephthalate (PET) substrate that is coated a conductive layer and a
ruthenium dioxide (RuO2) sensitive membrane with the technologies
of screen-printing and RF sputtering. For data analysis, we also
prepared a dynamic measurement system for acquiring the response
voltage and analyzing the characteristics of the working electrodes
(WEs), such as sensitivity and linearity. In this condition, an array
measurement system was designed to acquire the original signal from
sensor array, and it is based on the method of digital signal processing
(DSP). The DSP modifies the unstable acquisition data to a direct
current (DC) output using the technique of digital filter. Hence, this
sensor array can obtain a satisfactory yield, 62.5%, through the design
measurement and analysis system in our laboratory.
Abstract: A new, simple and highly sensitive kinetic
spectrophotometric method was developed for the determination of
trace amounts of Ru(III) in the range of 0.06-20 ng/ml .The method
is based on the inhibitory effect of ruthenium(III) on the oxidation of
Rhodamine B by bromate in acidic and micellar medium. The
reaction was monitored spectrophotometrically by measuring the
decreasing in absorbance of Rhodamine B at 554 nm with a fixedtime
method..The limit of detection is 0.04 ng/ml Ru(III).The relative
standard deviation of 5 and 10 ng/ml Ru(III) was 2.3 and 2.7 %,
respectively. The method was applied to the determination of
ruthenium in real water samples