Influence of Calcium Intake Level to Osteoporptic Vertebral bone and Degenerated Disc in Biomechanical Study

The aim of the present study is to analyze the generation of osteoporotic vertebral bone induced by lack of calcium during growth period and analyze its effects for disc degeneration, based on biomechanical and histomorphometrical study. Mechanical and histomorphological characteristics of lumbar vertebral bones and discs of rats with calcium free diet (CFD) were detected and tracked by using high resolution in-vivo micro-computed tomography (in-vivo micro-CT), finite element (FE) and histological analysis. Twenty female Sprague-Dawley rats (6 weeks old, approximate weight 170g) were randomly divided into two groups (CFD group: 10, NOR group: 10). The CFD group was maintained on a refmed calcium-controlled semisynthetic diet without added calcium, to induce osteoporosis. All lumbar (L 1-L6) were scanned by using in vivo micro-CT with 35i.un resolution at 0, 4, 8 weeks to track the effects of CFD on the generation of osteoporosis. The fmdings of the present study indicated that calcium insufficiency was the main factor in the generation of osteoporosis and it induced lumbar vertebral disc degeneration. This study is a valuable experiment to firstly evaluate osteoporotic vertebral bone and disc degeneration induced by lack of calcium during growth period from a biomechanical and histomorphometrical point of view.

Long-Term Study for the Effect of Ovariectomy on Rat Bone - Use of In-Vivo Micro-CT -

In the present study, changes of morphology and mechanical characteristics in the lumbar vertebrae of the ovariectomised (OVX) rat were investigated. In previous researches, there were many studies about morphology like volume fraction and trabecular thickness based on Micro - Computed Tomography (Micro - CT). However, detecting and tracking long-term changes in the trabecular bone of the lumbar vertebrae for the OVX rat were few. For this study, one female Sprague-Dawley rat was used: an OVX rat. The 4th Lumbar of the OVX rat was subjected to in-vivo micro-CT. Detecting and tracking long-term changes could be investigated in the trabecular bone of the lumbar vertebrae for an OVX rat using in-vivo micro-CT. An OVX rat was scanned at week 0 (just before surgery), at week 4, at week 8, week 16, week 22 and week 56 after surgery. Finite element (FE) analysis was used to investigate mechanical characteristics of the lumbar vertebrae for an OVX rat. When the OVX rat (at week 56) was compared with the OVX rat (at week 0), volume fraction was decreased by 80% and effective modulus was decreased by 75%.